LCZ-35Q 35kV Manual Switch CT Current Transformer Indoor Insulated Structure

Xi'an Xigao Electricenergy Group Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Weibei industrial zone, Lintong district, Shanxi. CHINA

Contact name:Emma

Inquir Now

Xi'an Xigao Electricenergy Group Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

LCZ-35Q 35kV Manual Switch CT Current Transformer Indoor Insulated Structure

Country/Region china
City & Province shanxi
InquireNow

Product Details

1.LCZ-35Q 35kV Indoor Old Semi-Closed Insulation Structure Manual Type Switchgear Current Transformer


LCZ-35Q current transformer is semi-closed insulated cast product, suitable for power metering, current measurement and relay protection in power system with rated frequency of 50Hz or 60Hz and rated voltage of 35kV and below.
This product conforms to IEC44-1 and GB1208 "current transformer".


2.The structure of


This TYPE OF current intercurrent device is semi-closed pillar structure, the primary winding is poured in epoxy resin, and the secondary winding and iron core are installed outside.
LCZ-35Q current transformer has strengthened external insulation and is a working condition product.
LCZ-35G is suitable for switchgear with width of 1.2 m.


3.The principle of use


1) The connection of the CT shall comply with the series principle: that is, the primary winding resistance shall be connected in series with the circuit under test, and the secondary winding resistance shall be connected in series with all instrument loads
2) Select appropriate changes according to the measured current, otherwise the error will increase. At the same time, one end of the secondary side must be grounded to prevent the high pressure of the primary side from running into the secondary low pressure side once the insulation is damaged, which may cause personal and equipment accidents
3) The open circuit of the secondary side is absolutely not allowed, because once the open circuit is opened, the current I1 of the primary side will all become the magnetizing current, causing a sharp increase in φm and E2, resulting in oversaturated magnetization of the core, serious heating and even burning the coil; At the same time, over-saturating magnetization of the magnetic circuit increases the error. Current transformer in normal work, the secondary side is akin to short circuit, if all of a sudden make its open circuit, the excitation electromotive force by the numerical small change value of great value in the core flux present serious saturation flat wave, therefore the secondary winding through zero in magnetic induction out high steeple wave, its value can reach thousands or even tens of thousands of volts, Endanger the safety of the staff and the insulation performance of the instrument. In addition, the open circuit of the secondary side makes the voltage of the secondary side reach hundreds of volts, once touched, it will cause electric shock accident. Therefore, the secondary side of the current transformer is equipped with a short circuit switch to prevent the open of the secondary side. In the process of use, once the secondary side open circuit should immediately remove the circuit load, and then, and then power off treatment. Take care of everything before you use it again.

 

4.TECHNICAL PARAMETER

 

Ratde Primary Current(A)Accuracy Classes(1S/2S)Rated Secondary Output (VA)4S Thermo Stability Current(kA Virtual Value)Dynamic Stability Current(kA Peak)
0.2S,0.20.5S,0.510P1010P15
150.2S/10P 0.5S/10P 0.2/10 0.5/10P 0.2/0.5204030203.157.8
204.511
306.315
40922.5
5012.53.5
751637.5
1002562.5
15031.578
200
30030506050
40050
500
600
80045100
100055
120063130
150072
200080

 

5.TECHNICAL DRAWING 

 

 

6.FAQ:

 

1. Send the technical data, better for all useful information; we will make a good recommendation.

possible please attach one reference picture to avoid any misunderstanding or any links from our website for we get a better understanding.

2. The lead time depend on quantity of order. Some standard type is on stock. Otherwise, it will take 3-15 days.

3. Usually shipped by sea, small order or urgent order we can send you by air.

4. All our activities are accredited to ISO 14001:2015 and IEC standard.

5. Technology ensure the quality satisfy international request.

 

Hot Products

1. AC Power Distribution Switchgear 40.5kv 33kv High Voltage Power Distribution Switchgear is a ...
1. 7.2kV 12kV 17.5kV LV Low Voltage Switchgear For Ac Power Grids LV Low Voltage Switchgear is used ...
Indoor LV Power Distribution Switchgear 24kV 36kV 40.5kV Power Distribution Switchgear is widely ...
1. 33kv 40.5KV Electrical Distribution Switchgear GB3906 Standard Electrical Distribution Switchgear ...
1.LW36kV SF6 HV Overload Switch Circuit Breaker Load Switch LW36-126/T3150-40 outdoor high voltage ...
1.LW8-40.5 SF6 Heavy Duty High Voltage Circuit Breaker Lw8-40.5 product has excellent crushing ...