Home Companies HCB Battery Co., Ltd

Li MnO2 Cell Lithium Manganese Dioxide Battery Stable Performance CR15270

HCB Battery Co., Ltd
Active Member

Contact Us

[China] country

Address: No.1 Special Taizhong Avenue, Gaoqiao Industrial Park, Wujiashan Economic Development Zone, Wuhan, Hubei, China

Contact name:

Inquir Now

HCB Battery Co., Ltd

Li MnO2 Cell Lithium Manganese Dioxide Battery Stable Performance CR15270

Country/Region china
City & Province wuhan hubei
Categories Bromide
InquireNow

Product Details

Li MnO2 Cell Lithium Manganese Dioxide Battery Stable Performance CR15270

 

 

 
Nominal Capacity800mAh
Battery discharged at continuous current 1mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃
Nominal Voltage3.0 V
Maximum Continuous Current800mA
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃
Maximum Pulse Discharge Current1500mA
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃
Storage Condition

Temperature ≤ 30℃

Humidity ≤ 75%RH

Operating Temperature-40℃ to +85℃
Battery DimensionSee drawing on pag
Max Weight13.0g
Self-discharge Rate2%
Max self-discharged rate at ambient temperature 23±2℃
Shelf Life10 years
Ambient temperature 23±2℃
 

 

1. Battery Characteristic

 

  • High Voltage

Each cell nominal voltage up to 3.0V

  • High Energy Density

Specific energy density up to 184Wh/kg

  • Wide Operating Temperature Range

The battery with a strong adaptability to temperature can be in work between -40℃ ~ +85℃

  • Long Shelf Life

Under the condition of normal temperature, the battery self -discharge rate of no more than 2% per year

 

High capacity, stable performance, without passivation

 

Battery sealing using the fully sealed structure to reduce the leakage of the battery, make the battery can be stored at room temperature for more than 10 years

 

High safety performance, reliable and environmental friendly

 

2. Main Applications

 

  • Telecommunications

Wireless telecommunication devices

  • Marine & signaling

Life jacket, signal light, buoy, etc.

  • Infrastructures

Automatic meters (water meter, electric meter, gas meter), conventional meters, etc.

 

3. Manufacturing Advantages

 

  • The technology in HCB is advanced and automatic;
  • Our manufacturing process of cathode is unique and advanced;
  • Varity of solutions including high power, high capacity (hermetic & semi sealing), low temperature etc;
  • Combing suggestions and multiple cascade and parallel connecting ways are workable for HCB;
  • HCB products are reliable because they have over 10 years storage date.

 

4. Company Advantages

 

  • The quality management system in HCB is accord with GB/T19001-2008/ISO9001:2008 standard;
  • The Environment Management System in HCB is accord with GB/T24001-2004/ISO14001:2004;
  • The drop test is workable of HCB battery;
  • HCB can provide the report for safe transport of goods to the customers;
  • CE Standard is workable for HCB Battery;
  • Rosh Standard is workable for HCB Battery;
  • We can provide you with the UL certificate if you need;

 

5. FAQS of General Safety Instructions

 

  • In order to keep the battery safely, what should we do?

 

In order to store the battery, the environment should be dry enough.

 

  • When the abnormal heat release or leakage occurs, what should we do?

 

The battery should be stopped to using when the abnormal heat release or leakage occurs.

 

  • What is the first step when you would like to use our battery?

 

The manual should be read before the battery is used.

 

  • What are you careful with if there are children beside when you use the battery?

 

Keep battery out of the children. If swallowed, please contact a physician at once.

 

  • What is the effect of the signs + and - on the battery?

 

You need to follow the signs + and - on the batteries and make sure not to reverse. If batteries are wrongly used, they will be hot very fast and can lead the gas and other toxic materials leakage.

 

  • Can the batteries be mixed to use on different electrochemical system, grades or brands?

 

When changing batteries be aware that batteries of different electrochemical system, grades, or brands should be not mixed. If different batteries are used or in case of using old and new batteries together this can discharge batteries due to different voltage or capacity. This can cause toxic material or gas leakage and/or violent rupture.

 

  • Is it ok to put the batteries into the water?

 

The water explosion will be caused if you throw the batteries into the water.

 

Hot Products

Long Life 8500mAh Lithium Thionyl Chloride Cell ER26500 Lithium Battery Nominal Capacity 8500mAh ...
3.6V Cylindric Lithium Thionyl Chloride Primary Lithium Battery ER34615+UPC1550 for Smart Metering ...
Lithium Battery , Primary Cell Battery For Temperature Detector International Standard CC Nominal ...
ER26500 Lithium Thionyl Chloride Cell Cylindrical Batteries​ International Standard C Nominal ...
Professional Li SOCl2 Lithium Battery 3.6 V , Lithium Thionyl Chloride Cell Nominal Capacity 3500mAh ...
CR17335SC Lithium Manganese Dioxide Battery No Inner Pressure At Room Temperature 1.Key Features: ...