1.5.4 Motor Cable for Servomotors SGMAH / SGMPH 200V Series Part
no: DP9325252-##G SGMAH, SGMPH-01Axx - SGMPH-08Axx DP9325254-##G
SGMPH-15Axx (##: cable length, 03 = 3m; 05 = 5m; 10 = 10m; 15 =
15m; 20 = 20m)
No. Description Colour
1 Phase U Black (white 1)
2 Phase V Black (white 2)
3 Phase W Black (white 3)
4 free -
5 Free -
6 Frame ground Green/Yellow
1.5.5 Motor Cable for Servomotors with Brake SGMAH / SGMPH 200
Series Part no: DP9325253-##G SGMAH, SGMPH-01AxxxC - SGMPH-08AxxxC
DP9325255-##G SGMPH-15AxxxC (##: cable length, 03 = 3m; 05 = 5m; 10
= 10m; 15 = 15m; 20 = 20m)
1.6 Specification of Encoder Connector 1.6.1 Encoder Connector
(Encoder side) Part – No: S RU C 17G MR WN 087
Electrical datas (at 20°C) (0,25 mm²) (0,50 mm²)
Conductor resistance : £ 82,0 W/km : £ 41,0 W/km
Insulation resistance : > 200 MWxkm
Screen attenuation up to 30MHz : 45 dB (approxiamate value)
up to 1 GHZ : 30 dB (approxiamate value)
(Test methode acc. IEC 96-1 Amend. 2 (1993) A.5.6 „Line injection
method“)
Test voltage (C/C) : 2,0 kVeff
(C/S) : 1,0 kVeff
Operating voltage : 300V
Operating current (single cable) at ambient temperature
0,35mm² 0,25mm²
20°C : £ 4,5 A ; : £ 2,2 A
30°C : £ 3,8 A ; : £ 1,9 A
40°C : £ 3,2 A ; : £ 1,6 A
50°C : £ 2,5 A ; : £ 1,2 A
60°C : £ 1,9 A ; : £ 0,9 A
70°C : £ 1,2 A ; : £ 0,6 A
Temperature range (Transport & storage) : -70°C bis + 90°C
(Installation & handling) : -40°C bis + 90°C
(Operating) : -20°C bis + 80°C
Bending radius (Operating) : ³ 3 x cable-Æ
(several times) : ³ 7,5 x cable-Æ
(several times optimum): ³ 10 x cable-Æ
Bending strength (r= 10 x cable-Æ at 20°C) : ³ 5.000.000 cycles
reduced working life at higher operating temperatures.
Oil resistance : acc. VDE 0282 part 10
Hydrolyse resistance : acc. VDE 0282 part 10
Flame resistance : acc. VDE 0472 part 804 condition B
Approbation : VDE-expert evidence (VDE-REG-Nr.6589)
The jacket surface has low adhesion, this prevents a stickness by
contact.
All materials are halogenfree.
Applicable for use in flexible chain cable holder systems.
Not for use outdoor or in earth
When used as control cable the relevant installation and/or
applicance standards have to be regarded.