Home Companies SHENZHEN XINGJIA XINYUAN ELECTRONICS CO.,LTD

Al Rainproof IP54 LED Strip Power Supply 12V 400W 33.3A Tube Light Box

SHENZHEN XINGJIA XINYUAN ELECTRONICS CO.,LTD

Contact Us

[China] country

Trade Verify

Address: F3, Building A, No.28, 2nd Road XiaKeng, Tong de community, Bao long street, Long Gang District, Shenzhen

Contact name:Jacky

Inquir Now

SHENZHEN XINGJIA XINYUAN ELECTRONICS CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Al Rainproof IP54 LED Strip Power Supply 12V 400W 33.3A Tube Light Box

Country/Region china
City & Province shenzhen
Categories Switching Power Supply
InquireNow

Product Details

Al Rainproof LED Driver 12V 400W 33.3A Engineer LED Tube Light Box LED Transformer
 

Quick Detail:

  • Engineering application Rainproof type aluminum housing shell
  • AC/DC switching 12V 400W 33.33A single-switch LED driver
  • AC input voltage: 220V
  • 1600V High voltage test, full loading test and old aging test
  • Constant voltage driver apply for LED light strip, light box etc.
  • IP54 grade
  • 3 Years Warranty
  • Unit Size: 19.0*11.6*4.9CM 
  • Unit Weight: 465g

 
Description:
All these products adopt PWM high-frequency pulse width modulation technology, mature standardized production, strict 100% load-carrying aging, high and low voltage impact experiments and complete test records for development & production of LED driver through strictly quality control system and highly responsible attitude, thus have a good quality feedback during application.
Rainproof IP54 led drivers mainly have 5V, 12V, 24V series, from 150W, 200W, 250W,300W, 350W,400W,500W,1000W etc. they are mainly used for LED light strip, light box, module, signboard light, line light, wall wash light, underground light, protective tube and so on.
For rainproof, we have iron type , aluminum type, and stainless stell type. 
 
Specifications:

SeriesNameLED Driver
1Basic info12V 33.3A 400W
2ModelS-400W-12V-R( rainproof)
3MaterialAluminum
4Efficiency95%
5Rated input220VAC 50/60Hz
6Output VoltageDC12V±5%
7Output Current33.3A
8Output Power400W
9GradeIP54
10Protect

Shortage/Overload
Over voltage/Over current

13Dimension19.0*11.6*4.9CM
14Weight 

 
 
Rainproof IP54 LED drivers related models list:

ModelInput VoltageOutput ValueSize/cm
S-200W-5V-R220V5V 40A 200W19.0*11.5*4.5
S-300W-5V-R220V5V 60A 300W23.2*15.3*6.5
S-350W-5V-R220V5V 70A 350W23.2*15.3*6.5
S-150W-12V-R220V12V 12.5A 150W15.2*8.7*4.3
S-200W-12V-R220V12V 16.67A 200W15.2*8.7*4.3
S-250W-12V-R220V12V 20.8A 250W19.0*11.5*4.5
S-300W-12V-R220V12V 25A 300W19.0*11.5*4.5
S-400W-12V-R220V12V 33.3A 400W19.0*11.5*4.5
S-500W-12V-R220V12V 41.67A 500W22*11.5*6.0
S-1000W-12V-R-220V12V 83.3A 1000W29.5*14.6*8.2
S-400W-24V-R220V24V 16.67A 700W19.0*11.5*4.5
S-500W-24V-R220V24V 20.83A 500W22*11.5*6.0
S-1000W-24V-R220V24V 41A 1000W29.5*14.6*8.2

 
Applications:
Widely used in LED Lighting, LED display, LED strips, LED advertisement screen, LED sign, LED night light, LED lamp house, LED decoration, LED wall light, LED street light , LED wall light, LED backlight, LED tube, offices , hospital , schools , factories , plants, shopping malls, supermarkets, kitchen, fair cabinet and so on.



 
 
Test methods for switching power supply
1. withstand voltage testing
Definition: withstand the effective value of AC between specified terminals such as I/P-O/P, I/P-FG, O/P-FG, leakage current is generally allowed to be 10 MA and the time of 1 min.
1.2 Test conditions: Ta: 25 degrees Celsius; RH: indoor humidity.
1.3 Test circuit:
1.4 Description:
1.4.1 Voltage test is mainly to prevent electrical damage, through the input string of high voltage, affect the safety of users.
1.4.2 During the test, the voltage must be increased from 0V and reached the highest point within 1 minute.
1.4.3 Pay attention to the Timer setting of the tester when discharging, and switch the voltage back to 0V before OFF.
1.4.4 During the safety certification test, the transformer shall be separately measured. The temperature shall be 25 degrees Celsius, RH: 95 degrees Celsius, 48HR, and the transformer primary/secondary and primary /CORE shall be tested later.
1.4.5 Production line test time is 1 second.
 
2. Ripple noise (ripple noise voltage) testing
2.1 Definition:
Maximum (P-P) or effective value of the AC voltage component overlapped over DC output voltage.
2.2 Test conditions:
I/P: Nominal
O/P : Full Load
Ta: 25 ℃
2.3 Test circuit:
2.4 Test waveform:
2.5 Description:
2.5.1 The shorter the oscilloscope GND line, the better. The test line should be far away from the PUS.
2.5.2 Using a 1:1 Probe.
2.5.3 The Scope's BW is generally set at 20MHz, but it is better to set the BW to the maximum for the ripple noise of the current network products.
2.5.4 Noise and the use of the instrument, the environment is very different, so the test must indicate the test location.
2.5.5 Test ripple noise shall not exceed the original specification value +1%Vo.
 
3. Leakage current testing.
3.1 Definition:
Input the current flowing between the chassis (the chassis must be grounded).
3.2 Test conditions:
I/P: Vin Max) x 1.06 (TUV) / 60 hz
Vin max.(UL1012)/60Hz
O/P: No Load/Full Load
Ta: 25 ℃
3.3 Test circuit:
3.4 Description:
3.4.1 Both L and N need to be measured.
3.4.2 UL1012 R value is 1K5 and TUV R value is 2K/0. 15 uf.
3.4.3 Leakage current Specifications TUV: 3. 5 ma, UL1012:5 ma.
 
 
 

 

Hot Products

LED Driver For LED Strip 12 Volt 100 Watt Power Supply For LED Lights Strip Light Drivers Specificat...
Good Heat Release LED Driver 220V 12V 180W LED Power Supply Module 15A Aluminum Quick Detail: IP20 ...
12V Driver For LED Strip 12V 150 Watt Power Supply For Hollow Design Stips Lighting Quick Detail: ...
12 Volt 300 Watt Power Supply Neon Lamp 12 Volt Power Supply For LED Lights Indoor type aluminum ...
LED Power Supply 12V 30A 360W LED Driver 12V Ac Constant Voltage Hollow Heat Release Series Name LED ...
12V LED driver 400W 33A light box, led display signboard 50/60Hz LED transformer converter ...