Home Companies Henan Lanphan Industry Co.,Ltd

Chiller Lab Equipment 10L Chiller Circulator Ethanol For Rotary Evaporator

Henan Lanphan Industry Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: 13 Jinjiang South Road, Shangjie District, Zhengzhou City, Henan Province

Contact name:admin

Inquir Now

Henan Lanphan Industry Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Chiller Lab Equipment 10L Chiller Circulator Ethanol For Rotary Evaporator

Country/Region china
City & Province zhengzhou henan
InquireNow

Product Details

Chiller Lab Equipment 10L Chiller Circulator Ethanol For Rotary Evaporator

 

Chiller Description

 

DLSB 10L-30℃ Laboratory chiller adopts microcomputer intelligent control system. Low temperature cooling liquid circulating pump with low temperature cooling water (liquid) flow or low temperature constant temperature water (liquid) flow, in order to meet the needs of the cooling water and low temperature liquid cooling or constant temperature equipment, such as the rotary evaporation apparatus, fermentation tank, electron microscope, low temperature chemical reaction kettle, electron spectrometer, mass spectrometer, densimeter, freeze-drying machine, vacuum coating machine, reaction kettle, etc.

 

Chiller Principle

 

The low temperature cooling circulation pump of this equipment adopts microcomputer intelligent control system. Low temperature cooling liquid circulating pump with low temperature cooling water (liquid) flow or low temperature constant temperature water (liquid) flow, in order to meet the needs of the cooling water and low temperature liquid cooling or constant temperature equipment, such as the rotary evaporation apparatus, fermentation tank, electron microscope, low temperature chemical reaction kettle, electron spectrometer, mass spectrometer, densimeter, freeze-drying machine, vacuum coating machine, reaction kettle, etc.

 

Troubleshooting

 

Make sure the refrigerant used is correct. In most cases, more than 97% ethanol solution is required


Refrigerant filling should be kept on the same level with the coil in the liquid storage tank, but not too much or too little
Check whether the compressor has fluorine: ≥30L


It should be noted that when the refrigerant temperature is lowered to the set value by the refrigeration pump, it is forbidden to add any refrigerant to the cold storage.


When the pump runs slowly or the refrigeration is poor, the condenser needs to be cleaned

 

 

Precautions for Use

 

1. Check whether the inlet and outlet valves of the equipment are normally opened and whether the pressure is in the normal range.

 

2. Check whether the power supply of each device is in the open position.

 

3. Before using the cryogenic coolant circulation pump, add ethanol with refrigerant concentration ≥97% to the tank, and the medium level should not pass the refrigeration coil in the tank.

 

4, check the power supply: the power of the power supply should be greater than the total power of the instrument, the power supply should have a good "grounding" device;

 

5, the equipment should be placed in a dry and ventilated place, no obstacles within 500mm around the instrument;

 

6. Pay attention to the position of liquid level in the tank. If the liquid level is too low, add refrigerant media in time

 

7. When the equipment is working, the temperature of the inlet and outlet water pipes is high, so do not touch them to prevent frostbite.

 

8. After use, turn off all switches and cut off the power supply;

 

9. Clean the condenser regularly to avoid reducing product efficiency due to excessive dust;

 

Chiller Parameter

 

 

Product NameChiller
Product ModelDLSB 10L-30℃
Non-Loaded Minimum Temperature-30℃
Temperature Fluctuation±2℃
RefrigerantR404
Volume10L
Circulating Pump Power100W
Lift (Optional)6M
Net Weight54 kg
Gross Weight69 kg
Total Power1069W
CondationNew

 

 

 

 

 

Hot Products

Steam Distillation Essential Oil Perfume Extraction Rotary Evaporator Product Features 1. Better ...
Lab Scale Rotary Evaporator For Pilot Plant 5L Rotary Evaporator Advantages 1.Manual up and down ...
Steam Distillation Lab Rotary Evaporator Essential Oil Perfume Extraction Equipment Rotary ...
RE-501 Rotary Evaporator High Efficiency Heating Equipment Rotary Evaporator Advantages 1. Smooth ...
5L Rotary Evaporator With Motor Lift Digital Controller Motor Rotary Evaporator Description RE-501 ...
Lab Scale Mini Spray Dryer Equipment For Protein Whey Detergent Powder Spray Dryers Application 1. ...