High Quality High Frequency Electromagnetic Vibration Testing Equipment

 

 

Introduction:

Electro-dynamic Vibration Testing  Vibration testing machine is a simulation product is manufacturing, assembly and transportation and the use of the implementation stage of the various environments encountered, to identify whether the product bears the ability of environmental vibration, applicable to electronics, electromechanical, optoelectronic, automobile, toys and other industries of research, development, quality control, manufacturing.

 

 

 

Characteristics:

Ultra mute work; The machine base uses the high quality material, installs conveniently, the operation is smooth, does not need to install the The, the control circuit digitization control and the display frequency, the PID adjusts the function, causes the equipment work to be more stable, reliable, sweeps the frequency and the fixed frequency operation way, adapts to the different profession test request To solve the interference of the strong electromagnetic field to the control circuit, and to increase the working time set, so that the test product reaches the accurate test time.

 

 

Electro-dynamic Vibration Testing System Performance Data Sheet

 

Shaker (Model# EDM-2000)
Sine force (peak)30kN
Shock force (peak)60 kN
Frequency range5~2,600 Hz
Displacement (continuous)100 mm
Max. Velocity1.8 m/s
Max. Acceleration75 G
Armature Diameter445 mm
1st order resonant frequency2,400 Hz
Allowable eccentric moment>500 Nxm
Armature weight40 kg
HE/ST screw dimensionM10 (metric)
Axial vibration isolation frequency<3 Hz
Max. Payload500 kg
Magnetic flux leakage≤1 mT
Dimensions (L×W×H, unpacked)1,330x860x1,250 mm
Weight (unpacked)2,500 kg
InstallationRubber mat (anchor bolts required)
Power Amplifier (Model# VSA-H323A)
Amplifier output30 kVA
SNR>65 dB
Rated output voltage120 Vrms
Amplifier efficiency> 90%
Dimensions (L×W×H, unpacked)800x900x2,100 mm
Weight (unpacked)500 kg
Blower (Model# PBL-W30)
Air volume0.46 m3/s
Power7.5 kW
Air duct diameter200 mm
Air pressure8.8kPa
InstallationAble to connect to ceiling (up to two 90 degree bends), max 20’ run
Horizontal Slip Table (Model# 30ST-600M)
Dimensions600x600 mm
Thickness45 mm
Frequency limit2,000 Hz
Effective mass54 kg

Note:

1. High pressure oil-film bearing is used for better uniformity.

Vibration Controller and Accelerometer
Vibration Controller VT-9008-44 Channel Vibration Controller with Sine and Self Calibration.
Accelerometer EA-YD-181100mV/g, Range: 50g, Working Freq.: 1-10kHz, Weight: 11gram, with 10ft low noise cable
Other supported functions/accessories
Environmental chambersSupported
Mobile devicesCustomizable
Insulation boardsCustomizable
FixtureCustomizable
Working environment of the system
Temperature range0-40℃
Humidity range0~90% , no condensation
Power requirements380V/3ph/50Hz, 40kVA
Compressed air pressure0.6 Mpa
 
 

 

 

How to use

1, the control manual to complete the procedure

2, such as Operation error so that can not work, you can use the recovery method of the steps of the input, and then set a single group or other running steps.

3, before use to press the external start switch, appears COO namely lets go, opens the key.

4, Taiwan Body:

1 The table body foot sleeve as far as possible fixed

2 power supply on/work in the output line can not be unplugged

3 Place the level as far as possible

4 components can be changed, the line should not be changed or from the connection.

5 The Taiwan body must not be all or part of the reorganization, only according to specifications for a single component and with the original confirmation password.

5, the amplitude inside the code

1. Do not adjust too large before or after the boot

2) low-key amplitude of high amplitude modulation

3 Control Panel Amplitude Knob placed in the middle position test items: placed to focus on the main point, reduce the left flat right.

4 control Box: Can not be placed on the top or underground operation

6, Inside Code:

1) reset when running or operating incorrectly

2) Control The Reset method step, each inside code only set one time to save can

3 usually must use the internal code can not be set randomly

7, Control Box:

1) The connecting line of the body must be locked tightly after hanging

2 the vibration direction switch and the output connection line are correspondence, can not connect the wrong

8, testing: Non-special test should use full wave test

9, the Taiwan body: can not produce the collision sound, the upper and lower center axis mutual touch will cause the spring steel piece rupture to be immediately shut down, amplitude modulation is adjusted small then turns on.

10, other unknown:

Do not arbitrarily change internal components and lines

 
 
Electro-dynamic Vibration Testing System Images

Hot Products

UV Anti-Yellowing Aging Test Chamber General Specification Packaging Dimensions: (W*D*H): 134*90...
UV Light Accelerated Aging Environmental Test Chamber Generl Specifications Packaging Dimensions: ...
Programmable Simulated UV Environmental testing machine UV aging equipment Applications 1. To get ...
150L Automatic Controllable Simulated Environmental Ozone Aging Equipment Chamber Structure And ...
Environmental Lab Equipment UVA Light Simulated Test Uv Aging Chamber Applications 1. Simulate the ...
Hot Sell Controllable Leather Test Simulated Environmental Anti-Yellowing Aging Machine Applications ...