Home Companies SKYLINE INSTRUMENTS CO.,LTD

IEC 60332-3-10 2000 IEC 60332-3-21~25 2000 Fire Testing Equipment Bunched Wires Vertical Flame Tester BWV

SKYLINE INSTRUMENTS CO.,LTD

Contact Us

[China] country

Trade Verify

Address: No.1802 Room 6# Building Universal Commerce Center Nancheng District Dongguan Guangdong China

Contact name:Ivy Xie

Inquir Now

SKYLINE INSTRUMENTS CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC 60332-3-10 2000 IEC 60332-3-21~25 2000 Fire Testing Equipment Bunched Wires Vertical Flame Tester BWV

Country/Region china
City & Province dongguan guangdong
Categories Solar Chargers
InquireNow

Product Details

IEC:IEC 60332-3-10:2000,IEC 60332-3-21~25:2000  Bunched Wires Vertical Flame Tester BWV
 
Bunched Wire Vertical Flame Spread Tester is a series conforming to IEC 60332-3-10 (Category A~D) standards. The test measures the expansion of vertical flame to the electronically or optically vertical cable or wire using the standard ignition source while supplying a certain amount of air to a chamber of a defined volume.
Additionally, if bunched cable vertical flame spread testers burner is adjusted by 20 degrees angle, it can be measure under IEEE 383(IEEE 1202) standard. Also, if Heat Release Facility is attached, it can measure fire dynamics value as H.R.R (Heat Release Rate), S.P.R (Smoke Production Rate) and so on.​
 
 
Test chamber has the dimension of 1,000±100(W) x 2,000±100(D) x 4,000±100(H) mm.
The bottom surface of the test chamber is higher than the ground while the rear side is supplemented with insulated material to insulate it from heat.At the lower section of the test chamber, there is a 800±20(W)x 400±10(D) sized hole at the 150±10mm position from the front side of the chamber to supply the air.

​There is a 300±30(W)x1,000±100(D) sized exhaust hole at the rear corner of the top section of the test chamber to allow emission of the smoke during the test.

​A flame trap is installed at the front side of the burner of the vertical flame spread tester to prevent backfire by propane to ensure the utmost safety.

​Unlike the conventional IEC60332-3 equipment, the vertical flame spread tester records all control and test conditions with the computer to add user friendliness.

​If stop the excessive combustion test due to Water Spray device installed for extinguish.

​The program on the requirement on standard and 70,000Btu/h can be program.

​Wide stainless steel ladder dimensions: 500(W) ×3, 500(H) mm.

​Standard stainless steel ladder dimensions: 800(W) ×3, 500(H).

Two sets of standard propane burner and venturi mixtures.

​Follow the standard category can program for select a test.
 
 
How does fire retardant work?
Fire retardant contains salts (typically fertilizers) that alter the way wildfires burn, decreasing fire intensity and slowing the advance of the fire, even after the water in the fire retardant has evaporated. The water in long-term fire retardants serves primarily to aid in uniform dispersal of the chemical over the target area.

Hot Products

ISO 871 Plastic Ignition Temperature Tester Application According to the GB4610-2008 plastic hot air ...
BS 476-7 Surface Spread Flame Tester for Measuring the Flame Extension of The Wall Product ...
ISO5660 Cone Calorimeter Analysis Instrument For Heat Release Product introduction Cone Calorimeter ...
Mask Flame Retardant Tester​ Product Introduction This mask flame retardant tester is developed ...
FMVSS 302 Horizontal Flammability Tester Product introduction The instrument consists of two parts: ...
16 CFR1633 Mattress Heat Emission Tester Product introduction CFR 1633 Mattress Heat Emission Tester...