Wire Flame Test Chamber For Electric Cables Under Fire Conditions Circuit Integrity

SKYLINE INSTRUMENTS CO.,LTD

Contact Us

[China] country

Trade Verify

Address: No.1802 Room 6# Building Universal Commerce Center Nancheng District Dongguan Guangdong China

Contact name:Ivy Xie

Inquir Now

SKYLINE INSTRUMENTS CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Wire Flame Test Chamber For Electric Cables Under Fire Conditions Circuit Integrity

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

Wire Flame Test Chamber For Electric Cables Under Fire Conditions Circuit Integrity

 

Standards

IEC 60331-21

Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV

 

Specification

2. Cable and cable line integrity combustion test machine design principle:

The cable and cable integrity fire tester is divided into three parts: the combustion box, the combustion frame, and the control box, all of which are individually movable. Each device is equipped with casters at the bottom for easy movement and sanitation. A device used for cables and cables that require line integrity when using a flame with a temperature of not less than 750 ° C (control of heat output) for individual fire test

Cable and cable line integrity combustion test machine technical parameters:

1. Design of the combustion chamber

It is fixed to the angle iron bracket with a suitable material to form the entire cubic combustion chamber.

Combustion chamber: inner dimensions: 3M x 3M x 3M total 27 cubic meters.

Can be brick wall structure or steel plate structure, selected by customers

2. Sample holder: The sample consists of two or three metal ring supports with an inner diameter of approximately 150 mm.

3. Burning device:

(1) Blowtorch: A propane gas burner with a nominal length of 500 mm and a width of 15 mm for a nozzle with a venturi mixer.

(2) Flow meter: air flow meter: 80L/min, propane flow meter: 5L/min

(3) The composition of the blowtorch control system: pressure regulating valve, piezoelectric igniter, flameout device, temperature control thermocouple,

Gas source (owned by your company), ignition device, gas pipeline, flow meter, venturi mixer,

Blowtorch, ball valve, air line, compressed air bottle (owned by your company)

(4) Timer: 0~99.99s/m/h can be set arbitrarily

(5) Ignition device: for automatic ignition

(6) Temperature controller: consists of two temperature monitoring sections,

Temperature range: 0~1000°C can be set arbitrarily.

4. Line load:

(1) Test transformer: 3000VA three (2) Test voltage: AC1000V

(3) Test current: 3A

 

 

What are the different types of cabling?
Cables are mainly used to carry electrical and telecommunications signals. There are various types of cables, including twisted pair cable, coaxial cable, multi conductor cable and fiber optic cable. A twisted pair cable has two cables twisted around each other and is mainly used to carrying signals.

 

Hot Products

ISO 3008-2007 Flammability Testing Equipment Vertical Burning Test Furnace Application Suitable for ...
Textile Fabrics Vertical Fire Testing Equipment CFR 1615/1616 For Knitted Fabric Application ...
Vertical Flame Resistance Textile Apparatus Use This apparatus is used to evaluate the flame ...
ISO15025 Protective clothing Flammability Tester SL-F40 Application This protective clothing ...
16 CFR 1611 Vinyl plastic film flammability tester ,SPI Flammability Tester Product information SPI ...
Thermal Conductivity System Tester Application Applicable to: thermal conductivity of clay and sand ...