Home Companies Advanced Instruments Co.,Limited

50KV VLF Withstanding Voltage Tester Very Low Frequency For Cable Testing

Advanced Instruments Co.,Limited

Contact Us

[China] country

Trade Verify

Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China

Contact name:Sandy

Inquir Now

Advanced Instruments Co.,Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

50KV VLF Withstanding Voltage Tester Very Low Frequency For Cable Testing

Country/Region china
City & Province changsha hunan
Categories Other Chargers
InquireNow

Product Details

 

50KV Very Low Frequency (VLF) Withstand Test Set

 

I. Introduction:

The VLF withstand test set is suitable for testing cables, transformers, switchgear, Rotating machinery, and other Electrical apparatus

 

 

II. Functions

1. Fully automatic microcontroller makes the vlf withstand test set easy to operature.
2. Built-in printer is designed with this equipment
3. True sine wave output 
4. Real-time display of actual output waveform is available.
5. Ergonomic, menu guided, large backlit LCD
6. Storage of test results for later retrieval and print.
7. Over voltage and current protected
8. Variable frequency 0.1Hz, 0.05Hz, 0.02 Hz
9. Data of current, voltage and waveform directly sampled at HV side.
10. AC testing does not degrade good cable insulation
11. Harmful space charges are not injected into the cable insulation
12. No traveling waves are generated during testing
13. Rugged and reliable design less prone to failure from transients

 

 

III.Safety Feature

  • Short circuit protected.
  • Status display of all important safety functions and messages.
  • Safe, easy to use operation with emergency off and key switch lock-out.
  • Fully integrated discharge circuit to safely ground the DUT after testing.
  • Zero start interlock.
  • Zero voltage switching.

 

IV. Specifications:

1. Input: 220 ± 10% Volts AC, 50/60 Hz, single phase.
2. Output-Voltage. 50KV
3. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz.
4. Stability of frequency: Fluctuation < 0.5%
5. Measurement accuracy: ± 3%.
6. Positive and negative voltage peak errors: ≤ 3%.
7. Voltage waveform distortion: ≤ 5%
8. Construction: In two units: Controller and Booster.
9. Ambient conditions of use: Temperature Indoor and outdoor: -10ºC to + 50ºC.
10. Humidity: ≤ 85%

 

ModelRated Voltage/current

Load Carrying

Capacity

Power fuseProduct Structure and Weight
30

30kV/20mA

(Peak)

0.1Hz,≤0.5µF~1.1µF5A

Controller:4kg

Booster: 25kg

0.05Hz,≤0.5µF~2.2µF
0.02Hz,≤0.5µF~5.5µF
50

50kV/30mA

(Peak)

0.1Hz,≤0.5µF~1.1µF7A

Controller:4kg

Booster: 50kg

0.05Hz,≤0.5µF~2.2µF
0.02Hz,≤0.5µF~5.5µF
60

60kV/30mA

(Peak)

0.1Hz,≤0.5µF9A

Controller:4kg

Booster Grade 1(30kV):25kg

Booster Grade 2(30kV):25kg

0.05Hz,≤0.5µF~1µF
0.02Hz,≤0.5µF~2.5µF
80

80kV/30mA

(Peak)

0.1Hz,≤0.5µF12A

Controller:4kg

Booster Grade 1(30kV):25kg

Booster Grade 2(50kV):50kg

0.05Hz,≤0.5µF~1µF
0.02Hz,≤0.5µF~2.5µF

 

80KV VLF is tested in Serbia customer's laboratory

Hot Products

Lateral Flame Spread Testing For Walls Surfaces Introduction Lateral Flame Spread Testing Equipment ...
Fire Propagation Index Testing Equipment for Laminated Foil BS476-6 FPT.pdf Introduction: BS 476-6 ...
ISO9239 FRPT.pdf Introduction: Critical Radiant Flux is the main parameters of the fire risk for ...
Introduction This Fire Test Equipment is developed base on the standard AS1530.2, test for ...
Introduction: The BS 476-12 Ignitability Tester is designed according to the BS476-12:1991. Method ...
Product Introduction The smoke toxicity test device (squirrel cage method) is applicable to the GB/T ...