15KV Digital Voltage Adustable Megohmmeter Megger

I.Introduction

For safety, before using the instrument must be well earthed,because the measured target connecting to high voltage power exists power frequency leakage.
Once high voltage being started, do not use manual discharge method to check the instrument. After test, please wait the instrument complete automatic discharge and automatically return to zero, then manual discharge can be operated. That is because electrical pulse caused by short-circuit discharge will damage the insulation life of the measured object; if the pulse fleeing into the instrument,it will also damage the integrated circuit inside the instrument.
The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment.

It also can be widely used for testing characteristics of insulation resistance in other area.

 

 

II. Main feature

 

1. With strong anti-electric field interference ability up to 2mA (50Hz), it is suitable for 500kV substation without dismantling wire to test insulation resistance of 500kV large-scale transformer.
2. The short-circuit current of test power> 5mA, maximum up to 15mA. Be suitable for testing high capacity and high inductance.
3. Wide resistance range from 0.5MΩ ~ 1999GΩ. With high-resolution, having accurate readings.
4. Wide voltage range: 0.25kV, 0.5kV, 1kV, 2.5kV, 5kV, 10kV, 15 kV/20kV, you can smoothly adjust voltage from 0V to the desired value.
5. With timekeeping function, remind users to record, and analyze absorptance and polarization index of measured target.

 

III.Technical Specifications

ModeTest voltageVoltage accuracyShort-circuit current
ADM-5kV0.25,0.5,1,2.5,5kV±(5%+10V)10mA
ADM-10kV0.5,1,2.5,5,10kV±(5%+10V)10mA
ADM-15kV1,2.5,5,10,15kV±(5%+10V)10mA
ADM-20kV0.5,1,2.5,5,10,20kV±(5%+10V)10mA

 

Range and accuracy

 

RangeResistance measurement rangeAccuracy
20MΩ/500V0.5~19.99 MΩ±(5%+5digital)
200MΩ/1000V5.0~199.9 MΩ±(5%+5digital)
2GΩ0.05~1.999 GΩ±(5%+5digital)
20GΩ0.5~19.99 GΩ±(5%+5digital)
200GΩ5.0~199.9 GΩ±(10%+10digital)
2000GΩ50~1999 GΩLess than 1000GΩ ± (20% + 10 digital) (humidity ≤70%)

Calibration voltage of MΩ range is 0.5kV; Calibration voltage of GΩ range is 2.5kV

Anti-electric field interference ability2mA(50Hz) 
Timekeeping and alarm functionmaximum value of stopwatch is 19 minutes and 59 seconds. 20 minutes for a cycle. The stopwatch will tell the time at these time points: 15 seconds, 60 seconds and every 60 seconds. When telling time, resistance readings hold for 5 seconds. If the measured resistance is below the lower limit of range, the reading is invalid and the instrument will continuously sound to give an alarm
Displaythree and a half bits LCD digital meter (three), respectively show test voltage, test resistance, test time
Power supply

10×1.2Vbattery(2000mAh Ni-MH rechargeable battery), total DC12V power supply

AC: 220V (50/60Hz)

Operating ConditionsTemperature:0~40℃Relative humidity:20~90%
Dimension315×240×155mm3
Weight5.5kg

 

Photo of 10KV and 5KV Megger Insulation Resistance Meter

 

 

Hot Products

ISO9239 FRPT.pdf Introduction: Critical Radiant Flux is the main parameters of the fire risk for ...
Introduction This Fire Test Equipment is developed base on the standard AS1530.2, test for ...
Introduction: The BS 476-12 Ignitability Tester is designed according to the BS476-12:1991. Method ...
Product Introduction The smoke toxicity test device (squirrel cage method) is applicable to the GB/T ...
Roofing Fire Test Equipment with Burning Brands by ENV 1187 Test 1 and ISO 12468-1 Product ...
Product Introduction Smoldering characteristic test furnace is mainly used in the fire performance ...