Home Companies Advanced Instruments Co.,Limited

Electrical Test Instrument for Transformer Winding Deformation Displacement Test

Advanced Instruments Co.,Limited

Contact Us

[China] country

Trade Verify

Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China

Contact name:Sandy

Inquir Now

Advanced Instruments Co.,Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Electrical Test Instrument for Transformer Winding Deformation Displacement Test

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

Transformer Winding Deformation Displacement Distortion Tester

I. Introduction:

Our company has designed the frequency response analyzer SFRA-II, which can use two methods to detect the deformation of the transformer at the same time. One is the sweep frequency response analysis method, the other is low-voltage short-circuit impedance method. Using two methods can effectively reduce incorrect judgments.

SFRA-II Transformer Winding Deformation Tester follows the national power industry standards DL / T911-2004 and DLT 1093-2008, and can be used for IEC60076-18-2012 and IEC60076-5-2006.

 

II.Main Features

1. Using the advanced technical of DDS;
2. Using the high speed and advanced microprocessor to design;
3. Using AD chip of 16 bits;
4. Transformer Winding Deformation Test Instrument adopts seven inch LCD touch screen of which the brightness can be adjusted;
5. With thermal printer of which the print thick can be adjusted;
6. It could store one hundred and twenty groups of FRA data, fifty groups of SCI data and thirty groups of SCI data, which could be read to current screen or upload to the PC;
7. With PC software using which we could upload data ,test, analyze data, print data, or create word document;
8. Transformer Winding Deformation Test Instrument uses USB2.0 to connect to the device;

 

 

III. Technical Specifications:

Sweep frequency response analysis

Two different sweep modes: Linear sweep, Section sweep
Linear sweep

10HZ-1MHZ interval 0.5KHZ 2000 dots

100HZ-2MHZ interval 0.5KHZ 2000 dots

10HZ-1MHZ interval 0.25KHZ 4000 dots(PC available)

100KHZ-2MHZ interval 0.25KHZ 4000 dots(PC available)

Frequency,interval,and scan dots can be set(PC available)

Section sweep

10HZ-100HZ interval 1HZ 90 dots

100HZ-1KHZ interval 5HZ 180 dots

1KHZ -10KHZ interval 50HZ 180 dots

10KHZ-100KHZ interval 0.2KHZ 450 dots

100KHZ –300KHZ interval 0.5KHZ 400 dots

300KHZ – 1000KHZ interval 1KHZ 700 dots

Test range(-100dB) - (+20dB)
Test accuracy(-80dB) - (+20dB)0.2dB (-100dB) - (-80dB)1.0dB
Frequency accuracy< 0.01%
Signal input impedance> 1M Ω
Signal output impedance50 Ω
In-phase test repetition rate99.5%

 

Short-circuit impedance and generator rotor AC impedance:

AC impedance0~999.999Ω 0.2%±2 digits
AC voltage0~600V 0.2%±2 digits
AC ampere0~120A 0.2%±2 digits
Active power

cosφ>0.1 0.5%±2 digits

cosφ<0.1 1.0%±2 digits

Reactive power 0.2%±2 digits

Frequency45~65HZ 0.1%

 

Hot Products

ISO9239 FRPT.pdf Introduction: Critical Radiant Flux is the main parameters of the fire risk for ...
Introduction This Fire Test Equipment is developed base on the standard AS1530.2, test for ...
Introduction: The BS 476-12 Ignitability Tester is designed according to the BS476-12:1991. Method ...
Product Introduction The smoke toxicity test device (squirrel cage method) is applicable to the GB/T ...
Roofing Fire Test Equipment with Burning Brands by ENV 1187 Test 1 and ISO 12468-1 Product ...
Product Introduction Smoldering characteristic test furnace is mainly used in the fire performance ...