Light WeightLab Equipments Mechanical Pipettes ( Adjustable & Fixed ) , Micro Pipette

Model:MicroPette

 

 

 

All DRAGONLAB pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.

 http://www.dragon-lab.com/en/Public/Uploads/image/20150105/b7214367.jpg
 

 

Features for MicroPette


- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
-  Easy to calibrate and maintain with tool supplied

- Design helps avoid repetitive strain injuries
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
- The low part is available for autoclaving
- Manufactured from innovative materials

Features for multi-channel MicroPette


- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips

 

  
Calibration

Please visit our website for online calibration at www.dragon-lab.com. Through the online calibration software, users can perform simple, accurate and timely calibration with free cost, and avoid the calibration error due to non-professional operation.

We will support and help you to achieve consistently excellent results.
http://www.dragon-lab.com/ckfinder/userfiles/images/xzjm.jpg

 

 

 

Specifications

 

 

Single-channel Adjustable Volume Pipettes
Volume RangeIncrementTest VolumeMaximum permissible systematic error (Inaccuracy)Maximum permissible random error (Imprecision)
%μL%μL
0.1-2.5μL0.05μL2.5μL2.50%0.06252.00%0.05
1.25μL3.00%0.03753.00%0.0375
0.25μL12.00%0.036.00%0.015
0.5-10μL0.1μL10μL1.00%0.10.80%0.08
5μL1.50%0.0751.50%0.075
1μL2.50%0.0251.50%0.015
2-20μL0.5μL20μL0.90%0.180.40%0.08
10μL1.20%0.121.00%0.1
2μL3.00%0.062.00%0.04
5-50μL0.5μL50μL0.60%0.30.30%0.15
25μL0.90%0.2250.60%0.15
5μL2.00%0.12.00%0.1
10-100μL1μL100μL0.80%0.80.15%0.15
50μL1.00%0.50.40%0.2
10μL3.00%0.31.50%0.15
20-200μL1μL200μL0.60%1.20.15%0.3
100μL0.80%0.80.30%0.3
20μL3.00%0.61.00%0.2
50-200μL1μL200μL0.60%1.20.15%0.3
100μL0.80%0.80.30%0.3
50μL1.00%0.50.40%0.2
100-1000μL5μL1000μL0.60%60.20%2
500μL0.70%3.50.25%1.25
100μL2.00%20.70%0.7
200-1000μL5μL1000μL0.60%60.20%2
500μL0.70%3.50.25%1.25
200μL0.90%1.80.30%0.6
1000-5000μL50μL5000μL0.50%250.15%7.5
2500μL0.60%150.30%7.5
1000μL0.70%70.30%3
2-10mL0.1mL10mL0.60%600.20%20
5mL1.20%600.30%15
2mL3.00%600.60%12
8-channel Adjustable Volume Pipettes
Volume RangeIncrementTest VolumeMaximum permissible systematic error (Inaccuracy)Maximum permissible random error (Imprecision)
%μL%μL
0.5-10μL0.1μL10μL1.50%0.151.50%0.15
5μL2.50%0.1252.50%0.125
1μL4.00%0.044.00%0.04
5-50μL0.5μL50μL1.00%0.50.50%0.25
25μL1.50%0.3751.00%0.25
5μL3.00%0.152.00%0.1
50-300μL5μL300μL0.70%2.10.25%0.75
150μL1.00%1.50.50%0.75
50μL1.50%0.750.80%0.4
12-channel Adjustable Volume Pipettes
Volume RangeIncrementTest VolumeMaximum permissible systematic error (Inaccuracy)Maximum permissible random error (Imprecision)
%μL%μL
0.5-10μL0.1μL10μL1.50%0.151.50%0.15
5μL2.50%0.1252.50%0.125
1μL4.00%0.044.00%0.04
5-50μL0.5μL50μL1.00%0.50.50%0.25
25μL1.50%0.3751.00%0.25
5μL3.00%0.152.00%0.1
50-300μL5μL300μL0.70%2.10.25%0.75
150μL1.00%1.50.50%0.75
50μL1.50%0.750.80%0.4
Fixed Volume Pipettes
Volume RangeIncrementTest VolumeMaximum permissible systematic error (Inaccuracy)Maximum permissible random error (Imprecision)
%μL%μL
5μL-5μL1.3%0.0651.2%0.06
10μL-10μL0.8%0.080.8%0.08
20μL-20μL0.6%0.120.5%0.1
25μL-25μL0.5%0.1250.3%0.075
50μL-50μL0.5%0.250.3%0.15
100μL-100μL0.5%0.50.3%0.3
200μL-200μL0.4%0.80.2%0.4
250μL--250μL0.4%1.00.2%0.5
500μL-500μL0.3%1.50.2%1.0
1000μL-1000μL0.3%3.00.2%2.0
2000μL-2000μL0.3%6.00.15%3.0
5000μL-5000μL0.3%150.15%7.5

Hot Products

Handheld Palm Portable Ultrasound Scanner , Ultrasonic Bladder Scanner With Trolley Model:MC-PBS-V31 ...
Thermal Ultrasonic Color Video Printer Print On Thermal Sensitive Paper Model:MC-P93W-Z Technical ...
MSK Portable Ultrasound Scanner Machine With 18 MHz High Frequency Linear Probe Model:MC-EBit 50 ...