300W High Frequency Diathermy Cautery Plastic Surgery Six working
Modes
Model: MCS-2000I-6
Features:
1. Microcomputer control.
2. Both monopolar and bipolar. Monopolar can be controlled by hand
or foot. Bipolar can be controlled by foot only.
3. Precise power control, can be used for all general surgical
procedures.
4. Touch control panel, three-way power output, with different
audible and visual indication during the process of outputting.
5. Automatic performance check during startup and Polar plate test.
6. Power Peak System provides surgeons with improved performance at
Lower power settings, minimizing the risk of tissue damage.
7. Full floating output system protects patient from tissue damage
caused by low frequency current.
8. Automatic compensation system ensures the stable output and
minimizes power consumption. Suitable for underwater surgery,
including fibrin-rich tissue cutting.
9. CVREM contact quality monitoring system which substantially
reduces the risk of burns under the patient return electrode. When
patient plate and skin are not well contacted, the system will
automatically stop the output and sound alarm.
10. Pencil Remoting Output. Surgeon can change the power output by
remoting control electrosurgical pencil.
Technical Specifications Of The Portable Cautery Machine:
Power: 220V±22V(110V±11V), 50Hz±1Hz
Operating frequency: 360~460kHz
Power rating: 880VA±10%
Six working modes:
Monopolar Cut:
a) Cut (pure cut):
1W~300W( Load 500Ω), apply to the operation of any tissue.
b) Bloodless cut (Blend1):
1W~250W(Load 500Ω), apply to the surgery of any tissue, proving a
good coagulation effect while cutting.
c) Fulguration (Blend2):
1W~150W(Load 500Ω), apply to endoscopic surgery, providing a good
homeostasis effect while cutting.
Monopolar Coag:
d) Coagulation1(Forced coag):
1W~150W( Load 500Ω), apply to ordinary open surgery, deep tissue
coagulation layer, has excellent homeostasis effect.
e) Coagulation2(Soft Coag):
1W~120W( Load 500Ω), suitable for endoscopic and other fine tissue
surgery with fast contact coagulation.
Bipolar:
f) Bipolar coagulation:
1W~50W(70W)( Load 100Ω), when tissue reach a good coagulation
effect, output power slow down, making a good homeostasis effect.
Power Consumption: ≦880VA(Cutting function 300W, Bipolar coagulation function 50W
output).
Packing list:
Name | Quantity |
Mainframe | 1set |
Remoting control pencil | 1piece |
Electrosurgical pencil | 5pieces |
Electrosurgical pad | 10 pieces |
Electrosurgical pad cable | 1piece |
Foot switch | 1set |
Tip clean sponge | 1piece |
Bipolar forceps and its cable | 1set |
Fuse | 3pieces |
Power cord | 1piece |
Operating manual | 1book |
Dimension:
G.t 14kg