Monkeypox Virus Real Time PCR Kit Vitro Qualitative Nucleic Acid Detection

Labnovation Technologies, Inc.
Active Member

Contact Us

[China] country

Address: 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China

Contact name:Aimee li

Inquir Now

Labnovation Technologies, Inc.

Monkeypox Virus Real Time PCR Kit Vitro Qualitative Nucleic Acid Detection

Country/Region china
City & Province shenzhen
Categories Dyestuff Intermediates
InquireNow

Product Details

Monkeypox Virus Real Time PCR Kit

Intended Use


This kit is used for in vitro qualitative nucleic acid detection of Monkeypox Virus in Human serum, lesion exudate samples and swab specimens. The test results of this kit are for clinical reference only and should not be used as the only standard for clinical diagnosis.
Monkeypox is a rare zoonotic disease characterized by skin eruptions caused by the Monkeypox virus (MPV) and whose clinical symptoms are similar to smallpox. Transmitted mainly through animals, humans can contract monkeypox from bites from infected animals or from direct contact with the blood, fluids and rashes of infected animals, and the virus can also be transmitted from person to person.

 

Specification

 

Product NameMonkeypox Virus Real Time PCR Kit
Detection ChannelsFAM
ICVIC
Ct Value35
Limit of Detection200 Copies/mL
Storage-20℃±5℃
TransportationUnder frozen condition
Shelf Life12 Months
Sample TypeNasal swabs, oropharyngeal swab, saliva, urine, lesion tissue, exudate, and blood, etc.
Package24 Tests/Kit,48 Tests/Kit,96 Tests/Kit
ComponentsPCR Reaction Buffer, PCR Enzyme Mixture, Positive control, Negative control

 

 


TEST PRINCIPLE

 

This kit adopts real time fluorescence PCR technology, which is suitable for nucleic acid detection of monkeypox virus extracted from clinical samples such as Human serum, lesion exudate samples and swab specimens Each reaction system contains specific primers and fluorescent probes to detect the virus, and the monkeypox virus nucleic acid can be qualitatively detected by collecting the fluorescent signal generated by PCR amplification.
In addition, specific primers and fluorescent probes for the internal standard control for human clinical specimen detection are added to each reaction system, and the collection, transportation and extraction process of the sample to be measured is monitored, indicating the false negative of the test result.

 


APPLICABLE INSTRUMENT

 

Real-Time PCR System: Molarray MA-6000, ABI 7500, ViiATM 7, QuantStudio 5, QuantStudio 6/7 pro, QuantStudio 6/7 flex, Agilent Mx3000P/3005P, Rotor-GeneTM 6000/Q, Bio-Rad CFX96 TouchTM/iQTM 5,Hongshi SLAN-96S/96P, AGS8830, AGS4800.

 

COMPONENTS

 
 
SpecificationsLQ-000301
24T
LQ-000302
48T
LQ-000303
96T
PCR Reaction Buffer336μL×1 tube672μL×1 tube672μL×2 tube
PCR Enzyme Mixture30μL×1 tube50μL×1 tube100μL×1 tube
Positive control50μL×1 tube100μL×1 tube200μL×1 tube
Negative control50μL×1 tube100μL×1 tube200μL×1 tube
Instruction for use (pcs)111

 

 

 

Hot Products

HPLC Automatic HbA1c Analyzer Stable and Sensitive Detection for Diabetes The HPLC automatic HbA1c ...
HPLC HbA1c Analyzer Detection of HbA1c Levels for Diabetes The full automatic analyzer provides ...
HPLC Automatic HbA1c Detection Analyzer for Diabetic LD-560 HPLC Automatic HbA1c Detection Analyzer ...
Diabetes Diagnosis HPLC Method Automated HbA1c Analyzer LD-560 Diabetes Diagnosis HPLC Method ...
Fully Automated HPLC Software HbA1c Analyzer HbA1c Levels Detection for Diabetes The Fully Automated ...
Large Size Touch Screen Fully Automated HbA1c Glycosylated Hemoglobin Detection Analyzer Intended ...