OEM Antibody Self Test Kit Severe Acute Respiratory Syndrome Coronavirus 2 Test Kit

Country/Region china
City & Province shenzhen
Categories Dyestuff Intermediates
InquireNow

Product Details

SARS-CoV-2 IgG/IgM Antibody Rapid Test Kit

Intended Use

The kit is used to detect the IgG and IgM antibodies to severe acute respiratory syndrome coronavieus 2(SARS-CoV-2) in human serum, plasma or whole blood sample qualitatively.

Specification

ItemSARS-CoV-2 IgG/IgM Antibody Rapid Test Kit
Sample TypeSerum/Plasma/Whole Blood
Products Shelf Life24 Months
Test SpeedWithin 15 minutes
Sample Volume1 Drop(20ul)
Package20 Tests/Kit
Storage Condition2℃-30℃

Main Components

  • Test Cassette
  • Disposable Pipette
  • Sample Buffer
  • Package Insert

Product Feature

  • Sample : One step operation process,easy for useing
  • Fast:Fast testing speed, get the result within 15 minutes
  • Accurate: High accuracy, specificity and sensitivity

 

Use Step

  • Remove the test device from the sealed pouch, place it on a clean and level surface with the sample well up.
  • Add serum or plasma (10µl) vertically into the sample well.
  • Add two (2) drops (80-100µl) of sample buffer into the sample well.
  • Observe the test results immediately within 15~20 minutes, the result is invalid over 20 minutes.

 

Interpretation of result

  • POSITIVE: Two or three distinct red lines appear. One line should be in the control region (C) and the other line would be in the test region (IgG line, IgM line or both).
  • NEGATIVE: One red line appears in the control region(C). No red or pink line appears in the test region (IgG line, IgM line).
  • INVALID: No red lines appear or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

Advantage

  • It can screen in the window period of infection onest also can indicate the previous infection and reduce the rate of missed diagnosis.
  • Blood sample detection, sinple operation, easy for use
  • Fast racation, results effective for 15 minutes

 

Hot Products

HbA1c Analyzer LD-560 HPLC System Fully Automated Analyzer For HbA1c Testing Intended Use LD-560 ...
LD-560 HbA1c Analyzer HPLC System for HbA1c Testing Intended Use LD-560 HbA1c analyzer is intended ...
LD-560 HbA1c Analyzer HPLC System for HbA1c Testing Intended Use The Fully Automated HbA1c Analyzer ...
LD-560 HPLC System for HbA1c Testing The Fully Automated HbA1c Analyzer is used in conjunction with ...
Analyzer For HbA1c Testing Labnovation Latest Analyzer LD-560 HbA1c Analyzer IFCC Certificated ...
Analyzer HbA1c LD-560 Latest Analyzer For HbA1c Testing Dual Mode For Option NGSP Certification ...