Home Companies Labnovation Technologies, Inc.

ISO SARS-CoV-2 Saliva Self Test Kit Immunochromatography Self Swab Test Kit

Labnovation Technologies, Inc.
Active Member

Contact Us

[China] country

Address: 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China

Contact name:Aimee li

Inquir Now

Labnovation Technologies, Inc.

ISO SARS-CoV-2 Saliva Self Test Kit Immunochromatography Self Swab Test Kit

Country/Region china
City & Province shenzhen
Categories Dyestuff Intermediates
InquireNow

Product Details

SARS-CoV-2 Antigen Saliva Rapid Test Kit Self-test For Home Use (Immunochromatography)


Intend Use
This rapid test kit is intended for the qualitative detection of SARS-CoV-2 antigen in human saliva sample from novel coronavirus suspected person with symptoms within 9 days from onset.

 

Product Details

ItemValue
Model NumberLX-401602
Type 1 Test
Warranty18 Months
Power SourceInstruction Manual
Quality CertificationCE
Safty StandardISO13485
After-sale ServiceOnline technical support
Sample volume3 Full drops
Test SpeedWithin 15 minutes

 

Product  Feature


 
Main Components

  • 1 Test Cassette
  • 1 Saliva Collectors With Collection Tube
  • 1 Sample Extraction Buffer
  • 1 Package Insert

 
Use Step

  • Open the cap of the collection tube and istall saliva collector.
  • Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
  • Screw the sample extraction buffer carefully.

  • Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
  • Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
  • Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.

 
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

 

 
Virus Sources

Global high frequency mutationAlpha / B.1.1.7(U.K.)Beta I B.1.351(South Africa)
Gemma I P.1(Brazil)Kappa I B.1.617.1(India)Delta I B.1.617.2(India)
C.37,ectAlpha I B.1.17(U.K.)B.1.36.16.etc
A.2.5,etcA.23.1Alpha I B.1.17(U.K.)
B.1.1.33.etcC.1.1.etc. 

 
Advantage

  • One-step Operation
  • High Accuracy, Specificity and Sensitivity
  • Individual Sample Buffer
  • Detection of mutations
  • Self-test At Home Use
  • Easy to collect specimen

Hot Products

Dengue IgM/IgG Antibody Rapid Test Kit (Immunochromatography) Specifications Test Item Dengue IgM...
Rapid Antibody Test Kit Dengue IgG/IgM Antibody Rapid Test Kit 25 Tests For Professional Use ...
Rapid Test Kit IgG/IgM Antibody Detection Dengue Diagnosis IgG/IgM Antibody Test Kit Intenden Use ...
Rapid Test Kit Dengue IgG/IgM Antibody Rapid Test Kit Professional Test High Accuracy 25 Tests Rapid ...
Rapid Antibody Test Kit Dengue IgG/IgM Rapid Test Kit 25 Tests Professionla Use High Quality Test ...
Rapid Test Kit Dengue IgG/IgM Antibody Detection Rapid Test Kit Professional Test 25 Tests Rapid ...