Home Companies Kingsine Electric Automation Co., Ltd.

K3166i Relay Testing Kit Secondary Injection Relay Test Set IEC61850

Kingsine Electric Automation Co., Ltd.

Contact Us

Trade Verify

Address: 6/F, Block 4-CD, TianAn Cyber Park, Futian District, Shenzhen 518048,.China

Phone: 86-00852-23892981

Contact name:Amy

Inquir Now

Kingsine Electric Automation Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

K3166i Relay Testing Kit Secondary Injection Relay Test Set IEC61850

City & Province shenzhen guangdong
InquireNow

Product Details

All-in-One design, Integrated IEC61850 SV & GOOSE, 6I+7V analog channels output, Inbuilt GPS and IRIG-B, and other advance functions.

 

 

  • Universal Relay Test Applications
  • Complied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc

  • 100/1000Mbit Fiber port for SMV and GOOSE simulations

  • 6x35A & 7x310V independent high burden output channels

  • 13 channels independent low-level signal outputs

  • AC/DC measurement (8 channels inputs, 0.1 class, 0-600V/0-5A, auto range)

  • Transducer calibration (0.02 class)

  • Energy meter calibration (Mechanical & Electronic meters)

  • Transient play back up to 3KHz

  • Lightweight, <18Kg

  • Fully function KRT software testing modules

  • 3-Years guarantee of free repair and life-long maintenance

  • Free software upgrade

 

Ordering Ref.

 

ModelCurrent OutputsVoltage Outputs
K31666×35A @ 450VA max / 3×70A @ 850VA max7×130V @ 75VA max
K3166i35A @ 450VA max / 3×70A @ 850VA max7×310V @ 90VA max
K316335A @ 450VA max / 3×70A @ 850VA max4×130V @ 75VA max
K3163i35A @ 450VA max / 3×70A @ 850VA max4×310V @ 124VA max
K313035A @ 450VA max4×130V @ 75VA max
K3130i35A @ 450VA max4×310V @ 124VA max

 

Able of what K31 series can test

 

ItemsANSI® No.
  IEC61850 numerical IEDs relay & merge unit 
  Distance protection relay  21
  Synchronising or synchronism-check relays  25
  Undervoltage relays  27
  Directional Power relays  32
  Undercurrent or underpower relays  37
  Negative sequence overcurrent relays  46
  Overcurrent/ground fault relays  50
  Inverse time overcurrent/ground fault relays  51
  Power factor relays  55
  Overvoltage relays  59
  Voltage or current balance relays  60
  Directional overcurrent relays  67
  Directional ground fault relays  67N
  DC overcurrent relays  76
  Phase-angle measuring or out-of-step protection relays  78
  Automatic reclosing devices  79
  Frequency relays  81
  Motor overload protection relays  86
  Differential protection relays  87
  Directional voltage relays  91
  Voltage and power directional relays  92
  Tripping relays  94
  Voltage regulating relays 
  Overimpedance relays, Z> 
  Underimpedance relays, Z 
  Time-delay relays 

 

 

 

Characteristics

 

  • 13 Channels (6x35A & 7x310V) outputs, Each output channels are independent and simultaneous control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to 20x harmonics.
  • Variable battery simulator, DC 0-350V, 140Watts max.

  • 13 Low-level channels outputs up to 8Vac/10Vdc max.

  • 0-600V / 0-5A AC/DC measurement in 0.1 class.

  • Graphical test modules and templates for testing of various relays

  • Quick relay testing facility in Manual mode

  • Shot/Search/Check, Point & Click testing

  • RIO/XRIO import & export facility

  • Switch on to fault test(SOTF)

  • Power system model for dynamic testing

  • Inbuilt GPS and IRIG-B sync end-to-end testing

  • Online Vector display

  • Automatic test results assume

  • Automatic test report creation

  • Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection

 

 

Parameter

 

 

 Voltage Outputs
 Output Range & Power 7×310 V ac (L-N) 90 VA max each
 3×620 V ac (L-L) 180 VA max each
 3×350 V dc (L-N) 140 W max each
 Accuracy

 AC: <0.03%Rd+0.01Rg Typ.

 <0.07%Rd+0.03Rg Guar.

 DC: ±10mV @ <5V, ±0.5% @ 5V
 Resolution 1mV
 Distortion <0.05%Typ. / <0.1% Guar.
 Current Outputs
 Output Range & Power 6×35A ac (L-N) 450 VA max each
 3×70A ac (2L-N) 850 VA max each
 1×100A ac (6L-N) 1200 VA max
 3×20A dc (L-N) 300W max each
 Accuracy

 AC: <0.05%Rd+0.02Rg Typ.

 <0.15%Rd+0.05Rg Guar.

 DC: ±5mA @ <1A, ±0.5% @ 1A
 Resolution 1mA
 Distortion <0.05%Typ. / <0.1% Guar.
 13 Low-Level Channel Outputs
 Quantity 13 Channels, 16 pin aviation socket
 Voltage Outputs Range AC 0~8V, DC 0~10V
 Current Outputs Range Nominal 2mA, 10mA max transient
 Output Power ≥0.5VA
 Accuracy

 (0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar.

 (0.8~8 Vrms): <0.02% Typ. / <0.05% Guar.

 Resolution 0.25mV
 Distortion(THD%) <0.05% Typ. / <0.1% Guar.
 Frequency & Phase Angle
 Frequency Range DC~1KHz, 3KHz transient
 Frequency Accuracy ±1ppm
 Frequency Resolution 0.001 Hz
 Phase Range -360°~360°
 Phase Accuracy <0.05° Typ. / <0.1° Guar. 50/60Hz
 Phase Resolution 0.001°
 IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function)
 Fiber Ports

 2 x 100Base-FX Full Duplex, LC type

 (Optional to 10/100Mbit, Ethernet RJ45 type)

 Fiber Type 62.5/125um (Multiple optical fiber, Orange Red)
 Wavelength 1310nm
 Transmit Distance >1Km
 Indicator

 Spd Green(light): Valid connection

 Link/Act Yellow(Blinking): Data exchanging

 Note: All hardware of this module are ready for active
 Aux. DC Voltage Source (Battery simulator)
 Range 0~350V @ 140W max
 Accuracy 0.5%Rg Guar.
 Binary Input
 Quantity 8pairs
 Type wet/dry, measurement
 Threshold 10~600Vdc or potential free, Programmable
 Time resolution 100us
 Debounce time 0~25ms (Software Controlled)
 Time range Infinite
 Time errors ±1ms @ 0.001~1s, ±0.1% @ >1s
 Galvanic isolation 4 isolated with each 2 pairs
 Binary Output (Relay Type)
 Quantity 4pairs
 Type Potential free relay contacts, software controlled
 Break Capacity AC Vmax: 400Vac / Imax:8A / Pmax:2500VA
 Break Capacity DC Vmax: 300Vdc / Imax:5A / Pmax:150W
 Binary Output (Semiconductor Type)
 Quantity 4pairs
 Type: Open-collector, 14 pin Aviation socket
 Break Capacity DC

 5~15Vdc / 5mA, 10mA max

 AC not permit

 Response time: 100us
 Synchronization
Synchronization Mode

 GPS, SMA type antenna connector

 IRIG-B, FT3

 IEEE1588

 Power supply & Environment
 Nominal Input Voltage 100~240Vac
 Permissible Input Voltage 85~264Vac, 125~350VDC
 Nominal Frequency 50/60Hz
 Permissible Frequency 45Hz~65Hz
 Power Consumption 1500 VA max
 Connection Type Standard AC socket 60320
 Operating Temperature -10℃~55℃
 Storage Temperature -20℃~70℃
 Humidity <95%RH, non-condensing
 Others
 PC Connection RJ45 Ethernet, 10/100/1000M
 Grounding Terminal 4mm banana socket
 Weight 18 Kg
 Dimensions(W x D x H) 468×375×164(mm)

 

 

Additional Information (Optional Modules)

 

 DC Measurement Input (Transducer calibrator)
 Voltage Input Range 0~±10V dc
 Max Input ±11V dc
 Accuracy <0.02% rg Typ. <0.05% rg Guar.
 Input Impedance 1Mohm
 Current Input Range 0~±1mA / 1~±20mA, auto range
 Max Input 600mA
 Accuracy <0.02% rg Typ. <0.05% rg Guar.
 Input Impedance 15 ohm
 AC/DC Measurement Input (Standard meter)
 Input Quantity 8 inputs (blend with binary input pairs)
 Voltage range 0~600Vrms (Rg:0.1V,1V, 10V, 60V, 600V)
 Voltage accuracy <0.1% Rg
 Current range 0~5Arms(clamp input)
 Current accuracy <0.1% Rg
 Sample rate 10KHz
 Input impedance 600KΩ
 Frequency range 45~65Hz, Accuracy < 0.01Hz
 Phase accuracy 0~360°, <0.2° Typ.
 Transient Recorder
 Input Quantity 8 input channels (blend with binary input pairs)
 Recorder time Max 50 Sec.
 Energy Meter Calibration
 Sensor Usage Mechanical meters / Electronic meters
 Sensor Output High lever:>4.5V, Low level:<0.2V
 Pulse Input 1 pulse input port
 Pulse Range 500KHz pulse input Max.
 Pulse Output

 1 Transistor output, Open-collector, 5-15Vdc/5mA

 

 

 

 

 

 

 

 

Hot Products

System Description K68i Relay Tester is new mode of All-in-One testing systems on relay protection ...
Able of what K31 series can test Items ANSI® No. IEC61850 numerical IEDs relay & merge unit Distance ...
Able of what K68 series can test Items ANSI® No. Distance protection relay 21 Synchronising or ...
rief instructions for templates installation and usage method: 1. Decompressing the "template_V3.x.x...
Part One: Features 1.All types of voltage, current, frequency, power, impedance, harmonic, ...
a. Current 1. No. of Generators 6 no. 2. Capacity 6x30A /3x60A /1x180Awithout using external ...