Home Companies Kingsine Electric Automation Co., Ltd.

Relay Test Set 7 Phase Voltage For Voltage , Current K60 Series

Kingsine Electric Automation Co., Ltd.

Contact Us

Trade Verify

Address: 6/F, Block 4-CD, TianAn Cyber Park, Futian District, Shenzhen 518048,.China

Phone: 86-00852-23892981

Contact name:Amy

Inquir Now

Kingsine Electric Automation Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Relay Test Set 7 Phase Voltage For Voltage , Current K60 Series

City & Province shenzhen guangdong
Categories Electric Wrenches
InquireNow

Product Details

Exclusive: 6*60A large current 

 

 

System Introduction

 

★ Use modularization switch power and self-RD hi-fi digital amplifier, with capacity efficient more than

 

    85%, high output power, low weight and small heating value, to make sure for long time and reliable

 

    ×10A output. Strong ability for overloading for reliable quality hardware.

 

★ Internal high-capacity SSD solid state disk, to make sure the normal running in the status of high speed

 

    moving or even tilting, so that the data will not lose when collision and shock.

 

★ Internal dual core CPU industrial PC, 9.7 inch large LED display screen, 1024×768 resolution,

 

    embedded Windows XPE system, to provide friendly interface for use for the onsite calibration at smart

 

    substations..

 

 

Functions Characteristic

 

1. 13pcs of channels simultaneous output, that is to output 7 phase voltage and 6 phase current with

 

    different amplitude, frequency, phase.

 

2. With wave form distortion test function, judgment of wrong wiring alarm, self-locking, housing grounding

 

    alarm.

 

3. Provide convenient and prompt all software calibration for amplitude and phase, no need to open the

 

    housing to calibrate the output precision.

 

4. 0~300V/0 .6A remote aux. DC power output.

 

5. To test by manual or automatic mode for various types of voltage, current, frequency, power,

 

    impedance, harmonic, differential, simultaneous relays, and can simulate various types of failure to

 

    perform the experiment of distance, zero sequence and reclose test. With GPS trigger function, to

 

    perform the test of reserve supply, prompt switch, etc.

 

6. Internal GPS function.

 

7. Optional function for standard meter, transducer, energy meter, etc.

 

 

 

K60 Series Tester Model List

 

ModelCurrentVoltage
K6066K60666×30A7×130V
K6066i6×30A7×300V
K6066S6×60A7×130V
K6063K60636×30A4×130V
K6063i6×30A4×300V
K6030K60303×30A4×130V
K6030i3×30A4×300V

 

 

K6066 Main Technical Parameters

 

 AC Voltage Source
 Output range 7-phase AC(L-N) 7×0~130V
 3-phase AC(L-L) 3×0~260V
 Output power 7×130 V (L-N) 1×70 VA max
 3×260 V (L-L) 1×110 VA max
 Precision

 ±2 mV (0.2 V~2 V)

 ±0.1% (2 V~130 V)

 Resolution 1mV
 AC Current Source
 Output range 6-phase AC(L-N) 6×0~30 A
1 phase AC(6L-N) 1×0~100 A
 Output power 6×30A(L-N) 6×220 VA max
 1×30A(L-N) 1×450 VA max
 1×100A(L-N) 1×1000 VA max
 Precision ±1 mA (0.2A~0.5A)
 ±0.1% (0.5A~20A)
 ±0.1% (20A~Imax)
 Resolution 1mA
 Frequency Output
 Range 5~1000 Hz
 Precision <0.001 Hz (5~65 Hz)
 <0.01 Hz (65~450 Hz)
 <0.02 Hz (450~1000 Hz)

 

 Resolution

 

 0.001 Hz
 Phase Output
 Range -360°~360°
 Precision <0.2°
 Resolution 0.1°
 Timing Function
 Timing range  0.1 ms~1.50×105 s
 Timing accuracy 

 ±1ms(0.001s~1s)

 ±0.1%(1s~1.50×105 s)

 DC voltage,DC current
 DC voltage Range 0~300V/180W
 Accuracy ±10mV (0.5 V~5 V)
 ±0.5% (5 V~300 V)
 DC current Range 0~30A/300W
 Accuracy

 ±5mA (0.2 A~1 A)

 ±0.5% (1 A~30 A)

 Aux.DC Voltage Source
 Range 0~300V/0.6A
 Binary Input
 Number 8pairs
 Compatible voltage 0V~250V
 Binary Output
 Number 4pairs
 Capacity 250V/3A (AC/DC)
 DC Measurement Input(Optional)
 Voltage Range 0~±10V,1MΩ
 Current Range 0~±20mA,15Ω
 Precision <0.05% RG
 AC Measurement Input(Optional)
 Voltage Range 0~130V,<0.2% RG
 Current Range 0~5A (Clamp-shape CT Connection),<0.5% RG
 Frequency Range 45~65 Hz,< 0.01 Hz
 Phase 0~360°,< 0.5°
 Harmonic 2~20times,<0.5% RG
 Synchronization 
 Synchronization mode  GPS
 Harmonic 
 Superimposed Numbers 2~20times
 Power Supply 
 Rated voltage  220V
 Power supply range 88~264VAC,125~350VDC
 Power 1500 VA
 Power supply frequency 47Hz~63Hz
 Working Condition
 Working temperature -20℃~70℃
 Humidity ≤95%, No condensation
 Weight & Size 
 Weight 17.5 kg
 Size 360×480×190(mm)
 Online interface RJ45

Hot Products

Protection Relay Testing / 50 Overcurrent Relay 3066i Relay protection test devices 1.Easy test 2...
GPS for orientation navigation , timing & frequency calibration High-precision measurement 12V DC ...
High Voltage Protection Relay Testing Relay protection test devices 1.Easy test 2.operation menu, ...
4 Phase AC Protection Relay Testing Relay protection test devices 1. Easy test 2. Operation menu, ...
220V Protection Relay Testing 1. Easy test 2. Operation menu, Simple operation 3. Power:1000VA 1. ...