Home Companies Kingsine Electric Automation Co., Ltd.

4 / 3 Phase AC Relay Secondary Injection Test Set RJ45 , VGA K68

Kingsine Electric Automation Co., Ltd.

Contact Us

Trade Verify

Address: 6/F, Block 4-CD, TianAn Cyber Park, Futian District, Shenzhen 518048,.China

Phone: 86-00852-23892981

Contact name:Amy

Inquir Now

Kingsine Electric Automation Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

4 / 3 Phase AC Relay Secondary Injection Test Set RJ45 , VGA K68

City & Province shenzhen guangdong
InquireNow

Product Details

4 / 3 Phase AC Relay Secondary Injection Test Set RJ45 , VGA K68

6.4 large LCD screen
4 pairs Binary output
Capacity:250V/3A AC/DC
4-phase AC (L-N)

The most-effective solution for relay testing!

With all in one design, able to test most of Relays by manual or automation!

 Software Features:
1. Able to test most of Relays by manual or automation: Voltage relays, Current relays, Frequency relays, Power relays, Impedance relays, Harmonic relays, Distance relays etc;
2. With self housing-grounding-detecting function, the software interface can show whether the housing well grounding or not, effectively ensure the safety of testing.
Hardware Features:
1. All-in-one design relay tester with 6.4 inches LCD display;
2. 4 Phase AC Voltage Sauce and 3 phase AC current sauce can be output together, even the Range, Phase, Frequency can be set independently;
3. Max AC voltage can reach 300V each phase, Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A (Poleless and adjustable);
4. Offer different type of computer port: USB port, RJ45 port, VGA Video Port , USB / RJ45 ports convenient for data transfer, VGA Video Port can connect to projector and easy for study and training;
5. Super long life Rotary encoder + Functional keyboard.


 Technical Data of K68

 

Voltage generators

Setting 

Range

4-phase AC (L-N)

4 x 0 ... 130V 

 

2-phase AC (L-L)

2x 0 ...260 V

Power

4-phase AC (L-N)

4 x70VA,  at 0 ...130 V

 

2-phase AC (L-L)

2 x 140VA,  at 0 ...260 V

Accuracy

<0.07% reading + 0.03% range guaranteed at 0-130V

<0.04% reading + 0.01% range typical at 0-130V

Resolution

1mV

Current generators

Setting

Range

3-phase AC (L-N)

3 x 0 ... 35 A

 

1-phase AC (3L-N)

1 x 0 ...105 A 

Power

3-phase AC (L-N)

1x 450VA,  at 0 ... 35A 

 

1-phase AC (3L-N)

1 x 1000VA,  at 0 ...105A

Accuracy

<0.14% reading + 0.06% range guaranteed at 0-35A 

<0.05% reading + 0.02% range typical at 0-35A

Resolution

1mA

Generators,  general

Frequency

Range

0 ... 1000 Hz

 

Accuracy / drift

Error < 0.001Hz at 10 ... 65Hz,

Error < 0.01Hz at 65Hz...450Hz

Error < 0.02Hz at 450Hz...1000Hz

 

Resolution

0.001Hz

Phase

Range

- 360° ... +360°

 

Accuracy / drift

Error < 0.2 °

 

Resolution

0.1°

Time

Range

0 ... 999, 999.999s

 

Accuracy / drift

Error<1ms

DC generators

Voltage ranges

0 ... 300V/180VA 

Current ranges

0 ... 20A/300W

Accuracy

Error <0.1% reading + 0.1% range guaranteed at 0…300 V;

Error <0.1% reading + 0.1% range guaranteed at 

0...20 A;

 

Resolution

1mA; 1 mV

Aux DC Supply

Range

0...300V/0.6A

Binary inputs

Number

8 pairs

Compatible Voltage

10V ... 250V  DC

Binary outputs

Number

4 Pairs

Capacity

250V/3A (AC/DC)

Synchronization

Synchronization mode

GPS

Harmonic

Harmonic overlap times

2 ... 9 times

Power supply

Nominal input voltage

220V±20% VAC,  1-phase

Power

1000VA

Nominal frequency

50±10% Hz

Environmental conditions

Operation temperature

-5°C ... 55 °C

Storage temperature

-20°C ... 75 °C

Humidity range

5% ... 90 %,  non-condensing

Weight

20KG

Dimensions

460(D)×140 (W)×360 (H) mm

Interface

RJ45 , USB, VGA

 Main Series Relay Tester List:

K68 series

K68

3x35A, 4x130V, 5 function modules,  Ethernet,  TFT LCD,  WinCE

K68i

3x35A, 4x300V, 5 function modules,  Ethernet,  TFT LCD,  WinCE

Major functions:

Items

IEEE(R) No.

Overcurrent relays

51/76

Inverse time overcurrent relays

50

Undercurrent relays

37

Ground fault relays

50

Directional overcurrent relays

67

Directional ground fault relays

67N

Overvoltage relays

59

Undervoltage relays

27

Directional voltage relays

91

Directional power relays

32

Power factor relays

55

Distance protection equipment (phase by phase)

21

Automatic reclosing devices 

79

Tripping relays

94

Voltage regulating relays

 

Overimpedance relays,  Z>

 

Underimpedance relays,  Z

 

Time-delay relays

 

 

Hot Products

Protection Relay Testing / 50 Overcurrent Relay 3066i Relay protection test devices 1.Easy test 2...
GPS for orientation navigation , timing & frequency calibration High-precision measurement 12V DC ...
High Voltage Protection Relay Testing Relay protection test devices 1.Easy test 2.operation menu, ...
4 Phase AC Protection Relay Testing Relay protection test devices 1. Easy test 2. Operation menu, ...
220V Protection Relay Testing 1. Easy test 2. Operation menu, Simple operation 3. Power:1000VA 1. ...
KF920 Fiber Universal Relay Test Set Features: Suitable testing for all kinds of Electro-magnetics ...