8 Inch High Resolution Color Screen M8 Multi-parameter Patient Monitor information storage and easy to recall

Model:M8 

Features:

• 6 Standard parameters: ECG, TEMP, NIBP, SpO2, RESP, PR

• 8 inch high resolution color screen

• Real time S-T segment analysis, pace-maker detection

• Indication of incorrect manipulation and malfunction analysis

• Patient info input management function

• Large volume of tabular and praphic trends information storage and easy to recall

• Capture 2-hour dynamic trend

• Various interfaces:standard screen,trend screen,oxyCRG screen,big front screen

• Up to 400 groups NIBP list,60 alarm event records recall, 7-day trend chart in storage.

• Up to 2 hours working capacity of built-in rechargeable

lithium battery

• Unique accessory management cabinet

• Networking capacity

ETCO2, cart, wall shelf are optional

 

 

Parameters:

 

ECG

 

Lead Mode 3-lead and 5-lead are optional

Lead Selection I, II, III, avR, avL, avF, V

Wave 5-lead: 2 channels

3-lead: 1channel

Gain ×2.5mm/mV, ×5.0mm/mV, ×10mm/mV,

×20mm/mV

HR Measuring and Alarm Range

Range 15 ~ 300 bpm

Accuracy ±1% or ±1bpm, which is greater

Alarm Accuracy ±2bpm

Resolution 1 bpm

ST Segment MonitoringMeasuring and Alarm Range -0.6 mV~ + 0.8 mV
AlarmAvailable
ReviewAvailable

Scan Speed for ECG

Waveform is adjustable

12.5mm/s accuracy ±10%

25mm/s accuracy±10%

50mm/s accuracy±10%

Respiration

 

Method R-F(RA-LL) Impedance

Differential Input Impedance >2.5 MΩ

Measuring Impedance Range 0.3~5.0Ω

Baseline Impedance Range 100Ω– 2500Ω

Bandwidth 0.3 ~ 2.5 Hz

Resp. Rate

 

Measuring and Alarm Range 0~120rpm

Resolution 1 rpm

Measuring Accuracy ±2 rpm

Alarm Accuracy ±3rpm

Apnea Alarm 10 ~ 40 S

NIBP

Method Oscillometry

Mode Manual, Auto, continuous

Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /

90/120/240/480/960 Min

Measuring Period in Continuous Mode 5 Min

Measuring and Alarm Range 10~270mmHg

Alarm Type SYS, DIA, MEAN

Resolution

 

Pressure 1mmHg

Cuff Pressure ±3 mmHg

Accuracy ±10% or ±8mmHg, which is greater

Over-pressure Protection:

Adult Mode 315±10 mmHg

Pediatric Mode 265±10 mmHg

Neonatal Mode 155±10 mmHg

SpO2

Measuring Range 0 ~ 100 %

Alarm Range 0 ~ 100 %

Resolution 1 %

Accuracy 70% ~ 100% ±2%

0% ~ 69% unspecified

Pulse Rate(PR)

 

Measuring and Alarm Range 0~250bpm

Resolution 1bpm

Measuring Accuracy ±2bpm or ±2%, which is greater

Alarm Accuracy ±2bpm

TEMP

Channel dual-channel

Measuring and Alarm Range 0 ~ 50°C

Resolution 0.1°C

Accuracy ±0.1°C

Actualization Interval about 1 Sec.

Average Time Constant < 10 Sec.

Alarm responding Time ≤2min

 

 

Packaging & Delivery

Packaging Details:Packing: 1 unit/carton
1* Patient monitor
reusable Spo2 sensor (1 pc);
ECG cable and leadwire (1 pc);
NIBP cuff and tube (1 pc);
Built-in lithium battery (1 pc)
1*English user manual (1pc)
Delivery Detail:Shipped in 7 days after payment
 

 

 

Hot Products

Max Sound Output: 129dB ± 4dB Max Sound Gain: 55dB ± 5dB Total Harmonic Distortion: ≤5% Frequency ...
MAX SSPL90:131 dBSPL HFA-SSPL90:125 dBSPL MAX GAIN: 67dB HFA-FOG:59 dB Frequency Range: 200~5969HZ ...
MAX SSPL90: 138 dBSPL HFA-SSPL90: 131 dBSPL MAX GAIN: 75dB HFA-FOG: 64 dB Frequency Range: 200...
MAX-SSPL90: 110dBSPL HFA-SSPL90:103dBSPL HFA-SPLITS:90dBSPL MAX GAIN :40dB HFA-FOG: 32dB Frequency ...
MAX-SSPL90: 110dBSPL HFA-SSPL90: 103dBSPL HFA-SPLITS: 90dBSPL Peak Gain:40dB HFA-FOG: 32dB Frequency ...
1.Max Sound Output: 129dB ± 4dB 2.Max Sound Gain: 45dB ± 5dB 3.Harmonic Wave Distortion: ≤5% 4.Input ...