healthcre 1

 

 

FDA and CE Approved 1.1" Color OLED display Healthcare Fingertip Pulse Oximeter SPO2 Pulse Rate Monitor CMS50C Oximetro Device

Model:CMS50C

 

Major Features

*Integrated with SpO2 probe and processing display module
*Small in volume,light in weight and convenient in carrying
*Operation of the product is simple , low power consumption
*SpO2 value display
*Pulse rate value display, bar graph display
*Pulse waveform display
*Battery capacity indication
*The display mode can be changed
*Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe

 

AH-50C Fingertip Pulse Oximeter 1AH-50C Fingertip Pulse Oximeter 2AH-50C Fingertip Pulse Oximeter 3

 

 

Main performance

Display Mode: 1.1" Color OLED display
Screen Resolution: 96*64
SpO2 Measuring Range: 0%~100%, (the resolution is 1%).
Accuracy: 70%~100%: ±2% , Below 70% unspecified.
PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)
Accuracy: ±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Power Consumption: less than 30mA
Voltage: DC 3.0V
Power Supply: 1.5V (AAA size) alkaline batteries * 2
Battery Working Hour: The minimum continually work time is 20 hours , theoretical number is 32 hours.
Safety Type: Interior Battery, BF Type

 

Accessories

Sell in standard:
*A hanging rope
*A user manual

Physical Identity
Dimension: 66(L) * 36(W) * 33 (H) mm
Weight: About 50g (with the batteries)

Qualification

Passed FDA and CE

 

Hot Products

Max Sound Output: 129dB ± 4dB Max Sound Gain: 55dB ± 5dB Total Harmonic Distortion: ≤5% Frequency ...
MAX SSPL90:131 dBSPL HFA-SSPL90:125 dBSPL MAX GAIN: 67dB HFA-FOG:59 dB Frequency Range: 200~5969HZ ...
MAX SSPL90: 138 dBSPL HFA-SSPL90: 131 dBSPL MAX GAIN: 75dB HFA-FOG: 64 dB Frequency Range: 200...
MAX-SSPL90: 110dBSPL HFA-SSPL90:103dBSPL HFA-SPLITS:90dBSPL MAX GAIN :40dB HFA-FOG: 32dB Frequency ...
MAX-SSPL90: 110dBSPL HFA-SSPL90: 103dBSPL HFA-SPLITS: 90dBSPL Peak Gain:40dB HFA-FOG: 32dB Frequency ...
1.Max Sound Output: 129dB ± 4dB 2.Max Sound Gain: 45dB ± 5dB 3.Harmonic Wave Distortion: ≤5% 4.Input ...