Small AC/DC Currents AC/DC Leakage Current Sensor Fluxgate Current Sensor

 

1. Description:

MD0630T41A-1 This current sensor is based on magnetic modulation and compensation principle, and can be used for measurement of small AC/DC current and leakage current, current difference between two or more conductors.

 

2. Overview:

- 100% Ageing Processing and Thermal Drift Test under high operating temperature in order to guarantee the long term stability of the sensors

- Custom makeable according to individual requirements

- Various current and voltage outputs are selectable

- Sensors with window for contactless measurements

- Apply for Isolation Monitoring of AC/DC power systems and cable selection systems, Measurements of small AC/DC currents and leakage currents etc.

MD0630T01A-1 IEC62752 Mode 3 EV Type B RCM 30mA AC 6mA DC Leakage Current Detector

 

3.Specification:

Voltage12V±20%
CurrentDC current 2~15mA, AC current 3~100mA
AccuracyDC±0.2mA, AC±0.3mA @ 25℃
3 Ways OutputDC alarm, AC alarm, AC/DC alarm
Operation Temperature Range-25~+80℃
Installation

Cable Type

Plastic CasingSIP encapsulation

 

 

4.Application Notessmart sensor

(1) Current value- Please specify your measurement range as per your application, for example if you are going to use it for detecting and sensing mA level or high current range such as 500A/600A shall be first factor.

(2) AC,DC,or both AC&DC shall be the second factor. Now current sensor on the market usually are AC or DC type.But if you need both AC& DC you may need to use IVY brand- AC DC leakage sensor.

(3) Parameters-Please confirm what kind of parameters shall be measured or detected. For example our smart sensor with shunt can readout current, voltage,kWh, kVar, Cosφ, Hz, THF, current cycle, starting waveform.

(4) Communication-RS485,M-bus, UART serial port are optional, if you have more requirements we can also develop for you.

(5) Installation Method, after making above decision you may also need to confirm the output terminal type, for example we have shunt / terminal / pillar / pins/ cable etc.

(6) As there are many models of smart electrical sensor, plz refer to the detailed specification and use it as per the instruction.

 

 

 

Hot Products

Insulation Failure Over Voltage Protection Circuit Overload Protection Relay 1. Introduction IM902 ...
Ovp Protection Electrical Power Supply Over-Voltage Protection Relay 1. Introduction IM902 is a 90A ...
Anti-Surge 3Ka Protective Relay Over-Voltage-Protection (Ovp) Load Switch 1. Introduction IM902 is a ...
Undervoltage Overvoltage Protector Surge Protective Device Spd Relay 1. Introduction IM902 is a 90A ...
Electrical Safty Over-Current And Short-Circuit Protection Relay 1. Introduction IM902 is a 90A ...
Supply Shut Down Magnetic Latching Relay Overload Relay 1. Introduction IM902 is an equipment ...