Home Companies Dongguan Quality Control Technology Co., Ltd.

Vertical Space 100mm Touch Screen Microhardness Vickers Tester Machine Auto Turret

Dongguan Quality Control Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: Room 301, Building No.1, No. 2 Jiaolian Yiheng Rd, Wanjiang District, Dongguan, China, 523046

Contact name:Raymond Chung

Inquir Now

Dongguan Quality Control Technology Co., Ltd.

Vertical Space 100mm Touch Screen Microhardness Vickers Tester Machine Auto Turret

Country/Region china
City & Province dongguan guangdong
Categories Slippers
InquireNow

Product Details

 

Vertical Space 100mm Touch Screen Digital Micro Vickers Hardness Tester with Auto Turret

 

Technical Data Download: iqualitrol Micro Hardness Tester iVick-455MT

 

Brief Introduction:

iVick-455MT Digital Micro Vickers hardness tester adopts unique precision design of optics, mechanic and electric features, make the indentation image clearer, and get more precise measurements.

 

iVick-455MT apply color touch screen and digital 10x eyepiece, which makes display and measurement intuitively and easily.

 

LCD screen can directly show the test mode, test force, indentation length, dwell time, test numbers, conversion scale, date and time.

 

As long as press the eyepiece button after measuring the indentation length, it can automatically get the hardness value and show on the large screen.

 

Test results can be saved for reviewing or be printed out by the built-in printer, and RS232 interface can connect with computer to transfer data.

 

Available to install optional Knoop indenter to measure Knoop hardness.

 

Support optional LCD video measuring device and CCD image automatic measuring system.

 

Application range:

Suitable for ferrous metal, non-ferrous metals, IC thin sections, coatings, ply-metals; glass, ceramics, agate, precious stones, thin plastic sections etc.; hardness testing such as that on the depth and the trapezium of the carbonized layers and quench hardened layers.

 

Technical Specification:

ModeliVick-455MT
Test Forcegf10gf, 25gf, 50gf, 100gf, 200gf, 300gf, 500gf, 1000gf
N0.098N, 0.246N, 0.49N, 0.98N, 1.96N, 2.94N, 4.90N, 9.80N
Test Range1HV~2967HV
Test ModeHV/HK
Loading MethodAutomatic (Loading/Dwell/Unloading)
TurretAutomatic Turret
Conversion ScaleHK, HRA, HRB, HRC, HRD, HRG, HRK, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T, HBW
Data OutputBuilt-in Printer, RS232 Interface
Hardness ReadingTouch Screen Display, Data can be saved
Objective10x (Observe), 40x (Measure)
Eyepiece10X
Total Magnification100x, 400x
Resolution0.0625μm
Dwell Time0~60s
Light SourceHalogen Lamp
X-Y Test TableSize: 100×100mm; Travel: 25×25mm; Resolution: 0.01mm
Max. Height of Specimen100mm
Throat98mm
Power SupplyAC220V/50Hz/1Ph, AC110V/60Hz/1Ph
Execute StandardISO 6507, ASTM E384, JIS Z2244, GB/T 4340.2
Dimension480×325×545mm, Packing Dimension: 600×360×800mm
WeightNet Weight: 31kg, Gross Weight: 44kg

 

Packing List:

NameQtyNameQty
Instrument Main Body1 set10x Digital Eyepiece1 pc
Diamond Vickers Indenter1 pc10x, 40x Objectiveeach 1 pc
Weights6 pcsWeight Axis1 pc
Cross Test Table1 pcFlat Clamping Test Table1 pc
Thin Specimen Test Table1 pcFilament Clamping Test Table1 pc
Horizontal Regulating Screw4 pcsLevel1 pc
Fuse 1A2 pcsHalogen Lamp 12V/15~20W1 pc
Power Cable1 pcScrew Driver2 pcs
Hardness Block 400~500 HV0.21 pcHardness Block 700~800 HV11 pc
Anti-dust Cover1 pcUsage Instruction Manual 

 

 

Vickers hardness test method:

The Vickers hardness test method consists of indenting the test material with a diamond indenter, in the form of a right pyramid with a square base and an angle of 136 degrees between opposite faces subjected to a load of 1 to 100 kgf. The full load is normally applied for 10 to 15 seconds.

 

The two diagonals of the indentation left in the surface of the material after removal of the load are measured using a microscope and their average calculated. The area of the sloping surface of the indentation is calculated. The Vickers hardness is the quotient obtained by dividing the kgf load by the square mm area of indentation.

 

When the mean diagonal of the indentation has been determined the Vickers hardness may be calculated from the formula, but is more convenient to use conversion tables.

 

 

The Vickers hardness should be reported like 800 HV/10, which means a Vickers hardness of 800, was obtained using a 10kgf force. Several different loading settings give practically identical hardness numbers on uniform material, which is much better than the arbitrary changing of scale with the other hardness testing methods.

 

The advantages of the Vickers hardness test are that extremely accurate readings can be taken, and just one type of indenter is used for all types of metals and surface treatments. Although thoroughly adaptable and very precise for testing the softest and hardest of materials, under varying loads, the Vickers machine is a floor standing unit that is more expensive than the Brinell or Rockwell machines.

 

 

Hot Products

Forced Air Precision Drying Oven with Volume 216L Forced air oven is designed to meet both ...
Xenon Lamp Temperature Test Chamber Weathering Test Equipment With Touch Screen Product Summary: ...
Three Layers Programmable Temperature Humidity Alternative Test Chamber Model: iTemp-K380A Brief ...
Touch Screen Controller UV Weather Resistance Test Chamber Conform ASTM Standard Technical Data ...
Touch Controller Large Size Walk in Programmable Temperature and Humidity Test Chamber Brief ...
Programmable Vertical Temperature and Humidity Test Chamber with Touch Screen Controller Technical ...