Product Details

Glaucoma Drainage Implant Model FPT

 

Glaucoma Drainage Implant Model FPT are small prosthetic devices that are placed to help lower the intraocular pressure and prevent further optic nerve damage. Glaucoma drainage implant surgery is an alternative to Glaucoma Filtration Surgery (Trabeculectomy). In some patients, particularly those with certain types of glaucoma such as aphakic glaucoma, neovascular glaucoma, and uveitic glaucoma,

 

Glaucoma Valve Model FPT for Glaucoma Surgery Material

Glaucoma Value Model FPT for Glaucoma Surgery is produced biomaterial ethoxyl methacrylate ester/methyl methacrylate copolymer(2-HEMA-co-NMA) which is nontoxic, has no immune response, has good biological compatibility, and cannot be absorbed by tissue. As materials of intraocular lens, it has been clinically applied in ophthalmology for more than ten years, and is universally accepted as good intraocular implantation material by ophthalmology circle.

 

Glaucoma Drainage Implant Model FPT Material Structure and Working Mechanism

Glaucoma Valve Model FPT for Glaucoma Surgery has four holes. Used for fixation on sclerotic bed and osmosis of aqueous humor, implant the Glaucoma Valve Model FPT for Glaucoma Surgery into resected deep sclerotic bed to form acavity which is called aqueous humor pond or depressurizing room, the upper bottom of linguiform one is exposed to the outside of sclerotic valve, that is made for aqueous humor being drained from the pond, cavity to the underside of conjunctiva, and promoting the formation of new aqueous humor channel, and thus to acheive the goal of reducing intraocular pressure.

 

Characteristics of Glaucoma Driange Implant Model FPT

1. Raw material: Hydrophilic acrylate. .

2. Which has good biological compatibility, and cannot be absorbed by tissue. .

3. Prohibit the growth of fibrocyte, and prevent the formation of filter channel cicatricle. .

4. To impel the formation of new aqueous humor drainage channel. .

5. Distributary of aqueous humor is formed after the implantation of drainage device.

6. It is safe for long-term usage, and intraocular pressure can be effectively controlled. .

7. To increase the success rate and reliability of Glaucoma operation.

 

 

Hot Products

Rigid polymethyl methacrylate (PMMA) Scleral fixation of intraocular lens (SFIOL) Scleral fixation ...
HA Hydrophilic Acrylic Foldable Intraocular Lens Iol Zero Aberration Hydrophilic IOLs tend to be ...
Modified C Haptic Hydrophilic Intraocular Lens In Cataract Surgeries Hydrophobic acrylic (HA) ...
Spherical 12.5mm Foldable Hydrophilic Iol High Tensile Strength Hydrophilic Iol initial popularity ...
Cataract Surgery Hydrophilic Intraocular Lens With Excellent Biocompatibility Hydrophilic and ...
Product Parameters: Product Name Heparin surface Modified aspheric IOLs Model PCF60/AH Power 4.0D-30...