24kv Indoor Single-Phrase Epoxy Resin Current Transformer for Protection
 
 
 
1.Product Introduction:

 

LZZBJ9-24-180b-2 LZZBJ9-24-180b-4 current transformer, epoxy resin casting insulation and fully enclosed support construction, encloses primary & secondary windings and annular core in the epoxy resin casting body. The product has the feature of light weight, omni-directional installation, withstanding nastiness and dampness. It is widely used for measuring current, electric energy and protective relaying in the electrical system with the rated frequency 50Hz or 60Hz and highest voltage for equipment 17.5(24) kv

 

 

2. Technical Data:



Main technical parameter
1. Rated insulation voltage: 24/50/125kV etc.
2. Rated frequency: 50/60hz
3. Installation Site: Indoor
4. Standards: IEC60044-1(IEC61869-1&2) 

 

 
3. Specification:
 
Rated current ratio(A)Secondary accuracy classes combination

Rated output

(VA)

Measuring current’s instrument security factorProtective current’s accuracy limit factorRated short-time thermal current (kA/S)Rated dynamic current ( kA)
MeasuringProtective
0.2(S)0.510P
20-200/5

0.2(S)/0.2(S)

0.2(S)/0.5

0.2(S)/10P

0.5/10P

10

15

1515

5

(10)

10

15

150I1n375I1n
300/531.580
400/531.580
500/540100
600/550125
800/52063125
1000/580160
1250/580160

 

 

 

Three secondary single ratio

Rated current ratio(A)Secondary accuracy classes combination

Rated output

(VA)

Measuring current’s instrument security factor(FS)Protective current’s accuracy limit factor(ALF)Rated short-time thermal current (kA/S)Rated dynamic current ( kA)
MeasuringProtective
0.2(S)0.510P
15-300/5

0.2S/0.5/10P

0.2/0.5/10P

0.5/0.5/10P

0.2S/10P/10P

0.2/10P/10P

0.5/10P/10P

1515

15

 

 

 

 

 

20

5

(10)

10

15

 

20

150I1n375I1n

400/5~

600/5

50105

800/5~

1000/5

63130
1200/580160
1500/580160
2000/5100200
2500/5125200
 
 
Three secondary double ratio
 
Rated current ratio(A)Secondary accuracy classes combination

Rated output

(VA)

FSALFRated short-time thermal current (kA/S)Rated dynamic current ( kA)
MeasuringProtective
0.2(S)0.510P

15-30/5

20-40/5

…..

500-1000/5

0.2S/0.5/10P

0.2/0.5/10P

0.5/0.5/10P

0.2S/10P/10P

0.2/10P/10P

0.5/10P/10P

1515

10

 

 

 

 

 

15

5

(10)

10

 

 

 

15

100I1n250I1n
600-1200/550105
750-1500/563130
800-1600/580160
1000-2000/580160
1250-2500/5100200
 
 
 
 
 
4. Outline Drawing:
 
 
 
 
 
 
5.Photos:
 
 
 
 

Hot Products

52kV outdoor MV PT epoxy resin full-closed for measuring and protective relaying 50/60Hz Chuangyin ...
Chuangyin Voltage Transformer-JDZW1-12R Description: This product is fully enclosed outdoor single...
36kV outdoor MV VT epoxy resin single phase for measuring and protective 50/60 Hz Chuangyin Voltage ...
17.5kV outdoor MV PT epoxy resin single phase for measuring and protective 50/60 Hz Chuangyin ...
17.5kV outdoor MV PT epoxy resin single phase double-pole for measuring and protective 50/60 Hz ...
36kV outdoor MV PT epoxy resin single-pole for measuring and protective 50/60 Hz Chuangyin Voltage ...