Home Companies Ningbo Wonsmart Motor Fan Co.,Ltd

High Speed 12v Dc Blower Fan Miniature Air Blower For CPAP Machine

Ningbo Wonsmart Motor Fan Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: Unit 3, Building 10, Huiding Chuangzhi Park, No. 228 Shengyuan Road, Fenghua District, Ningbo City, Zhejiang Province

Contact name:Julie

Inquir Now

Ningbo Wonsmart Motor Fan Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

High Speed 12v Dc Blower Fan Miniature Air Blower For CPAP Machine

Country/Region china
City & Province ningbo zhejiang
Categories Air Hammers
InquireNow

Product Details

12V dc high speed blower

 

High pressure and high speed 12v brushless dc mini centrifugal quiet cpap blower. Suitable for CPAP machine / air cushion machine/fuel cell/medical equipment and inflatables.


 

Product parameters

 

BrandWonsmart
Blower typeCentrifugal fan
BearingNMB ball bearing
Applicable IndustriesManufacturing Plant
Electric Current TypeDC
MountingCeiling Fan
Place of OriginZhejiang, China
Warranty1 Year
After-sales Service ProvidedOnline support
Controllerexternal
Weight80g
Speed@hall sensor frequency1Hz=60r/min
Size70mm*40mm
Life time(MTTF)>10,000hours (under 25 degree C)

 

 

Drawing

 

 

Blower Performance

 

12V dc high speed blower can reach maximum 16m3/h airflow at 0 kpa pressure and maximum 6kpa static pressure.When this blower run at 3kPa resistance if we set 100% PWM,it has maximum output air power.It has maximum efficiency,if we set 100% PWM. Other load point performance refer to below P-Q curve:

 

 

Applications:

 

This blower can be widely used onto air cushion machine, CPAP machine, SMD soldering rework station.

 

 

DC brushless blower advantage:

 

(1).12V dc high speed blower is with brushless motors and NMB ball bearings inside which indicates very long life time; MTTF of this blower can reach more than 20,000 hours at 20 degree C environmental temperature.

(2).This blower needs no maintence

(3).This blower drived by a brushless motor controller have many different control functions such as speed regulation,speed pulse output,fast acceleration, brake etc.it can be controlled by intelligent machine and equipment easily.

(4).Drived by brushless motor driver the blower will have over current, under/over voltage,stall protections.

 

 

How to use the blower correctly:

 

This blower can run at CCW direction only.Reverse the impeller running direction can not change the air direction.

Filter onto the inlet to protect the blower from dust and water.

Keep the environmental temperature as low as possible to make the blower lifetime longer.

 

 

FAQ:

 

Q: Do you also sell controller board for this blower fan?
A: Yes, we can supply adapted controller board for this blower fan.

 

 

Application

 

In medical ventilators, the system pressure (flow resistance) varies significantly during ventilation.As a result, it is difficult to control the flow rate if the magnitudes of the current flow rate and of expected system pressures are not known in advance with a good enough accuracy. The current system pressure can be measured and be used in a feedback control loop to control the blower via its electronic control circuitry. However, the system pressure changes in dependence on the actual flow rate, and the work point of the blower will change as well, responding to the fluctuating system pressure.This will cause instabilities in the medical ventilator, as a result of limits to the accuracy of the pressure sensor, the dynamic behavior of the sensor, etc., which in turn lead to unstable and inaccurate flow rate control.

 

Various systems are known in the art that control the flow. Conventionally, the gas flow rate is controlled by actuation of a gas flow valve. Together with a combination of a feed-forward flow control gain component and/or a feedback error correction (e.g., a proportional, integral and derivative error feedback control), this gives rise to the required response.

 

Another known method to control the gas flow rate is to make explicit use of the properties of the blower. Controllably varying the speed of the blower can be used to control the flow, based on the predetermined relationship between the system pressure and the flow rate.The blower is designed to respond quickly to a change in inspiration or expiration by means of minimizing its inertia. In this case, a feedback controller can be used as well for control of the gas flow. However, variations in the system pressure can change the flow rate, even at a constant blower speed. This problem cannot fully be solved with feedback control. The continuously changing system pressure usually leads to an unstable system or oscillations around the target flow.

Hot Products

WS7040/BRUSHLESS DC BLOWER 1. Compact size and tight structure make it easy to install and store, ...
WS4540/BRUSHLESS DC BLOWER 1. Three-phase brushless motor for efficient and quiet operation. 2. NMB ...
WS9250&WS9250C/BRUSHLESS DC BLOWER 1. The Wonsmart Mini Brushless DC Blower boasts a 24V direct ...
Ceiling Mounting 24VDC High Pressure Industrial Air Blower With Three Phase Brushless Motor Product ...
WS9260/BRUSHLESS DC BLOWER 1. Three-phase brushless motor for efficient and quiet operation. 2. NMB ...
13.5Kpa high pressure BLDC blower for air cushion machine WS9070 brushless DC blower is a highly ...