Home Companies Fuzhou Hosem Power Co., Ltd.

90kVA GPU Ground Power Unit

Fuzhou Hosem Power Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Rm526, C2 Building, Cangshan Wanda Plaza, No. 216 Pushang Road, Fuzhou City, Fujian, China.

Contact name:Jack Zheng

Inquir Now

Fuzhou Hosem Power Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

90kVA GPU Ground Power Unit

Country/Region china
City & Province fuzhou fujian
Categories Uninterrupted Power Supply (UPS)
InquireNow

Product Details

90kVA Ground Power Unit with 400Hz 200/115V , GPU for Supply Power to Aircraft

 

Main Performance and Technical Specification

1. GPU Output Technical Data

Genset Output123kW (DC Output and AC Output)
Output Type1) Generator Output: AC 400Hz 3Ph 200V;
2) DC 28.5V, Two Output, supply by alternator via rectifier;
3) Series connection two of DC28.5V: DC 56V
Output SpecificationAC 400Hz 3Ph 200V1) Rate Output: 90kVA;
2) Power Factor: PF=0.8 (Lagging);
3) Rate Voltage: 200/150V, 3Phase
4) Rate Frequency: 400Hz;
5) Rate Current: 288.6A;
6) Over Load Capacity: 432.9A 20 Seconds
DC28.5V1) Rate Voltage: DC28.5V (Two Lines);
2) Rate Current: 800A;
3) Surge Current: 1600A (5min), 2500 (60s);
4) When output with (2 X DC28.5V) series connection, one of the DC28.5V output is from 2 X 182AH batteries (7HK-182), another line without output.
 DC56V1) Rate Voltage: DC 56V;
2) Rate Current: 800A;
3) Surge Current: 1600A (5min), 2000A (30s);
4) Output Voltage 0-56V slow rise, rise time is adjustable.

90kW GPU for Aircraft

2. Overall Dimension and Weight:

Dimension of GPU

Overall Dimension: 3800*1800*2200mm
Total Weight: 4540kg
Noise Level: ≤75dB(A) at 7 Meters distance, and in 1 Meter height.

 

1.3 Specification of Cummins Diesel Engine For GPU: 

Cummins Diesel EngineModel6BTAA5.9-G12Rate Output(kW)144
Cylinder No.6Fuel Cons. (g/kw.h)204g/kW.Hr
Bore/ Stroke(mm)102/120Displacement(cc)5900
AspirationTurbochargerCompression Ratio17.3 : 1
Start Voltage (V)24Steady Adjustment (%)≤1

 

1.4 Specification of 400Hz Alternator: 

AC AlternatorModelH300-32Rate Voltage200/115V
Rate Frequency400HzPower Factor0.8(Lagging)
Rate Output72kW/90kVARate Current259.8A
Insulation ClassHVoltage Adjustment Range±5%
ProtectionIP23Steady Voltage Adjust Ratio≤±1%
Efficiency93%Excitation MethodBrushless Self-excitation
DC Rectifying AlternatorRate Voltage2 X DC 28.5VRate Current2 X 800A
Surge Voltage2500A/20sVoltage ControlAVR
Insulation ClassClass HVoltage Modulation24-32V(can adjust to 35V)
Voltage Slow Rise0—20S  

 

1.5: Control Panel: 

Use the Deepsea brand DSE5310 controller to control and protect the diesel engine and alternator.
Use the OMRON PLC CPIH-XA40 for output control and DC protection.

 

Control Panel of GPU with Deepsea DSE5310 Controller

 

2. Technical Data: Conform to MIL-STD704E Standard
2.1. Three Phase AC Power:
2.1.1. Rate Voltage 115/200V, 3 Phase Four Wires;
2.1.2. Rate Frequency: 400Hz;
2.1.3. Rate Output: 72kW/900kVA;
2.1.4. Power Factor: 0.8;
2.1.5. Rate Current: 259.8A;
2.1.6. Excitation Mode: Solidity, Self-excitation;

 

2.1.7. Voltage Standard:
2.1.7.1. Steady Voltage Range: 108-118V, from no load to full load;
2.1.7.2. When one phase output with 1/3 of rate current, and other two phase without output, the voltage unbalance will not exceed 4%;
2.1.7.3. Voltage modulation: ≤2.5V;
2.1.7.4. When in balance load, phase voltage shifting 120°±4°;
2.1.7.5. Distortion Ratio: ≤ 0.05;
2.1.7.6. Wave Crest Ratio: 1.31-1.51;
2.1.7.7. Phase Voltage Adjustment Range in No Load: 115±12V.
2.1.7.8. Transient State Voltage Recover Time Conform to MIL-STD 704E Chart 6 standard, Phase voltage transient state surge voltage range: 90 - 140 V, Steady voltage range: 113 - 117 V.
2.1.7.9. Add and Remove 100% Load, Deviation: ±20%;
2.1.7.10. Voltage Adjust Range: ±12V;
2.1.7.11. Three phase average sense and inner wiring voltage drop compensate maximum 5%(adjustable)


2.1.8. Frequency Standard:
(A) Rate Frequency: 400Hz;
(B) Steady Frequency Range: 396-404Hz;
(C) Frequency Steady Time: ≤1S in ±5Hz
(D) Frequency Modulation: <2Hz

 

2.1.9. A.C. Protection System
(A) Over Voltage Trip: Voltage exceed 126V(110% of rate voltage), delay 1-2seconds
(B) Low Voltage Trip: Voltage Lower than 101V(88% of rate voltage), delay 7 seconds.
(C) Over Frequency: Frequency Exceed 430Hz, delay 2-5 seconds, trip.
(D) Low Frequency: Frequency lower 370Hz, delay 1-3 seconds, trip
(E) Over Load: 125% of rate load for 5ninutes, trip, 150% of rate load for 10seconds, trip.


2.2 DC 28V Output, Two lines, output data:
(a) Ripple Wave: 1.5V RMS(Active Amount) @ 500A;
(b) Steady Voltage Range: 24-29V;
(c) Protection: in 32V(factory setting), delay 2seconds, trip;
(d) No Load Voltage Adjustment Range 24-32 VDC;
(e) Transient Surge Voltage: 17-35 VDC;


2.3 DC 56V Output Data(all data measure from the 15meters cable end socket):
1) Rate Voltage: DC 56V;
2) Rate Current: 800A;
3) Surge Current: 1600A(5min);2000A(30s);
4)Output Voltage 0-56V Slow Rise, Rise Time is adjustable.
5) Steady Voltage Range: 48-59V
6) Ripple Wave: 1.5V RMS(Active Amount) @ 500A,
7) Over Voltage Protection: When voltage at 63V(factory setting), delay 2seconds, trip.


2.4 Safety System:
2.4.1. Common Safety System
1)AC Cable interlock switch install in the E and F contact pin of connector, it will prevent power connection to air-craft, when incorrect connection of cable to aircraft is happened. There is a interlock bypass switch install in the GPU for testing mode.
2)Emergency Stop Switch install in the GPU for emergency stop the GPU, when it is necessary.
3)Safety interlock parts install in the battery circuit of truck to prevent the truck start and run, when the operator still have put the power cable storage bin with correction location.

 

2.4.2 GPU Engine Protection
1)Over Speed Protection
2)Low Oil Pressure Disconnection.
3)Engine high temperature disconnection.
4)High water temp.

TR of GPU for DC Output

 

 

 

Hot Products

Cummins Generator Set 350kVA Powered by NTA855-G4 Diesel Engine For Industrial Specification of ...
Standby 250kW Diesel Generator with Cummins NTA855-G1A Diesel Engine for Factory Specification of ...
Cummins Diesel Generator Set, 825kW Cummins Generator, 750kW Cummins Generator Set, Cummins Open ...
60kw Silent Diesel Generators 75kVA Power Gen Set , Cummins Engine Diesel Generator Specification: ...
250KW Waterproof Canopy Diesel Generators Power Plant , Cummins CCEC Engine , Stamford Alternator , ...
500kVA Diesel Genset In Parallel , Synchronization Generator Comap , High Voltage 6300V, 1100V, 13...