Home Companies HWATEK WIRES AND CABLE CO.,LTD.

PVC Sheath FT2 Flame 26AWG Multicore Flexible Cable

HWATEK WIRES AND CABLE CO.,LTD.

Contact Us

[China] country

Trade Verify

Address: NO.111, Qianjin Road, Baipu Town, Rugao City, Nantong City, Jiangsu Province.

Contact name:Jimmy Wang

Inquir Now

HWATEK WIRES AND CABLE CO.,LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

PVC Sheath FT2 Flame 26AWG Multicore Flexible Cable

Country/Region china
City & Province nantong jiangsu
Categories Power Cables
InquireNow

Product Details

UL2517 300V, 105℃, oil resistance, VW-1 flame retardant, PVC insulated elevator shaft wiring-control signal cable

1.Product Introduction with UL 2517

The wiring inside the elevator shaft with a rated voltage of 300V-the control signal cable is composed of copper conductor, insulation, filling, tape, shielding and outer sheath. The cable has the characteristics of high flexibility, high temperature resistance, oil resistance, flame retardancy, etc. At the same time, all materials of the cable comply with the latest environmental protection standards of RoHS&Reach.

2.Characteristicwith UL 2517

3.Application field with UL 2517

Mainly used for fixed installation of signal transmission cables in elevator shafts.

Scope of applicationRated voltageRecommended specificationsRecommended number of cores
Control cabinet → hoistway switch wiring
Safety circuit switch hoistway cable300V26AWG-14AWG7+1
Upper forced switch, lower forced switch, upper limit switch, lower limit switch, ladder lock switch, fire return switch300V26AWG-14AWG2+1
Door lock trunk cable and door lock branch cable in hoistway300V26AWG-14AWG2+1
Control cabinet → hoistway floor display wiring
Floor display main line cable, floor display branch cable300V26AWG-14AWGNumber of layers +N+PE
Note: The number of layers is 7 and above

4.Structure diagram with UL 2517

1- conductor,2- insulation,3- filling,4- Strap,5- shield(Optional),6- Outer sheath

Printing:E258652  AWM STYLE 2517 ***AWG 105℃ 300V VW-1— c  AWM I/II A/B 105℃ 300V FT1 -LF- HWATEK

5.Basic Information with UL 2517

Conductor : Solid or Stranded
Insulation: Special mixed PVC

Shield or Braid: optional

Jacket: Special mixed PVC

6.Implementing standards with UL 2517
International: UL758 , UL1581, UL2556

RoHS,REACH Compliant,

 

7.Technical data with UL 2517

Rated voltage:300V

Rated  Temperature:-40-105

Flame: VW-1, FT1, FT2
Oil resistance: 60 ℃ or 80 ℃ Oil

Voltage withstand test:AC 2.0kV/1min

 

8.Specifications with UL 2517

Number of cores*SpecificationsConductor structureConductor outer diameterAverage insulation thicknessInsulation outer diameterAverage thickness of sheathFinished outer diameterCable net weightMaximum conductor DC resistance (20℃)
  (mm)(mm)(mm)(mm)(mm)kg/kmΩ/km
2C*26AWG7/0.160.480.301.2±0.050.764.3±0.2019.2150
2C*24AWG7/0.200.600.301.3±0.050.764.5±0.2021.994.2
2C*22AWG7/0.2540.760.301.5±0.050.764.9±0.2027.059.4
2C*20AWG7/0.320.960.301.7±0.100.765.3±0.2033.736.7
2C*18AWG16/0.2541.150.301.9±0.100.765.7±0.2041.223.0
2C*16AWG26/0.2541.490.302.2±0.100.766.4±0.3055.214.6
2C*14AWG41/0.2541.870.302.6±0.100.767.2±0.3075.78.96
2C*18AWG+16AWG16/0.2541.150.301.9±0.100.766.2±0.2057.423.0
26/0.2541.490.302.2±0.1014.6
2C*18AWG+14AWG16/0.2541.150.301.9±0.100.766.6±0.3066.723.0
41/0.2541.870.302.6±0.108.96
3C*26AWG7/0.160.480.301.2±0.050.764.5±0.2022.0150
3C*24AWG7/0.200.600.301.3±0.050.764.7±0.2025.894.2
3C*22AWG7/0.2540.760.301.5±0.050.765.1±0.2032.059.4
3C*20AWG7/0.320.960.301.7±0.100.765.6±0.2041.436.7
3C*18AWG16/0.2541.150.301.9±0.100.766±0.2051.423.0
3C*16AWG26/0.2541.490.302.2±0.100.766.8±0.3071.014.6
3C*14AWG41/0.2541.870.302.6±0.100.767.6±0.3098.28.96
 
Number of cores*SpecificationsConductor structureConductor outer diameterAverage insulation thicknessInsulation outer diameterAverage thickness of sheathFinished outer diameterCable net weightMaximum conductor DC resistance (20℃)
  (mm)(mm)(mm)(mm)(mm)kg/kmΩ/km
3C*18AWG+16AWG16/0.2541.150.301.9±0.100.766.8±0.3069.723.0
26/0.2541.490.302.2±0.1014.6
3C*18AWG+14AWG16/0.2541.150.301.9±0.100.767±0.3078.123.0
41/0.2541.870.302.6±0.108.96
4C*26AWG7/0.160.480.301.2±0.050.764.8±0.2025.9150
4C*24AWG7/0.200.600.301.3±0.050.765±0.2030.494.2
4C*22AWG7/0.2540.760.301.5±0.050.765.5±0.2038.759.4
4C*20AWG7/0.320.960.301.7±0.100.766±0.2050.236.7
4C*18AWG16/0.2541.150.301.9±0.100.766.6±0.3063.423.0
4C*16AWG26/0.2541.490.302.2±0.100.767.3±0.3088.014.6
4C*14AWG41/0.2541.870.302.6±0.100.768.3±0.30124.38.96
5C*26AWG7/0.160.480.301.2±0.050.765.1±0.2029.6150
5C*24AWG7/0.200.600.301.3±0.050.765.4±0.2035.794.2
5C*22AWG7/0.2540.760.301.5±0.050.766±0.2046.359.4
5C*20AWG7/0.320.960.301.7±0.100.766.6±0.3059.936.7
5C*18AWG16/0.2541.150.301.9±0.100.767.1±0.3075.623.0
5C*16AWG26/0.2541.490.302.2±0.100.767.9±0.30106.014.6
5C*14AWG41/0.2541.870.302.6±0.100.769±0.30150.88.96
 
Number of cores*SpecificationsConductor structureConductor outer diameterAverage insulation thicknessInsulation outer diameterAverage thickness of sheathFinished outer diameterCable net weightMaximum conductor DC resistance (20℃)
  (mm)(mm)(mm)(mm)(mm)kg/kmΩ/km
5C*18AWG+16AWG16/0.2541.150.301.9±0.100.767.9±0.3095.723.0
26/0.2541.490.302.2±0.1014.6
5C*18AWG+14AWG16/0.2541.150.301.9±0.100.768.1±0.30104.323.0
41/0.2541.870.302.6±0.108.96
6C*26AWG7/0.160.480.301.2±0.050.765.5±0.2034.4150
6C*24AWG7/0.200.600.301.3±0.050.765.8±0.2041.394.2
6C*22AWG7/0.2540.760.301.5±0.050.766.5±0.3053.259.4
6C*20AWG7/0.320.960.301.7±0.100.767.1±0.3070.036.7
6C*18AWG16/0.2541.150.301.9±0.100.767.7±0.3089.223.0
6C*16AWG26/0.2541.490.302.2±0.100.768.6±0.30125.714.6
6C*14AWG41/0.2541.870.302.6±0.100.769.9±0.40179.08.96
6C*18AWG+16AWG16/0.2541.150.301.9±0.100.768±0.30104.323.0
26/0.2541.490.302.2±0.1014.6
6C*18AWG+14AWG16/0.2541.150.301.9±0.100.768.4±0.30115.323.0
41/0.2541.870.302.6±0.108.96
7C*18AWG+16AWG16/0.2541.150.301.9±0.100.768.3±0.30115.423.0
26/0.2541.490.302.2±0.1014.6
7C*18AWG+14AWG16/0.2541.150.301.9±0.100.768.4±0.30123.023.0
41/0.2541.870.302.6±0.108.96
8C*18AWG+2C*16AWG16/0.2541.150.301.9±0.100.7610.3±0.40157.623.0
26/0.2541.490.302.2±0.1014.6
12C*18AWG+2C*16AWG16/0.2541.150.301.9±0.100.7610.9±0.40196.223.0
26/0.2541.490.302.2±0.1014.6
Remark 1: The detailed dimensions and technical parameters are subject to our product specifications.

The above products are non-shielded standard models, and can also be customized according to customer requirements or actual usage.

9.Certificates with UL 2517

UL, CUL, CE

10.Packing and Shipping with UL 2517

  • The cargo could be packaged as Hwatek’s standard requirement if client no special request, such as carton, wooden pallet or wooden case;
  • If client put forward special packing requirements, Hwatek will specialize in custom materials and charge some fees;
  • Hwatek’ll pack the cargo according to the transportation requirements strictly, including size, weight and safety;
  • The cargo, manufacturer, packing details will be labeled on the outer packing;
  • About transportation agent, Hwatek will give priority to customers' advice. If not, we can come up with some proposals and choose good and affordable agents for clients reference;
  • Shipping term, It depends on the value of the goods and the will of the customer.

10.More pictures with UL 2517

Hot Products

UL444 CAT6A Outdoor Ethernet Network Data SFTP UTP LAN Shielded Camera Cable CAT6 Product Descriptio...
UTP Cat5e, CAT6 Network SFTP FTP UTP Shielded LAN Internet Camera Outdoor Communication Cable ...
CAT5 2P BK 100BASE-TX Patch Cable, UTP,50MHz, Pure Bare Copper, Snagless RJ4 22AWG, 35, Fullboot ...
CAT 5e S/FTP AWG26 x 4pairs TIA/EIA-568-B ,Twisted pair wires 80 °C 30V Cable Product Description ...
Rg58, Rg178, JIS Ultrasound Special Medical Equipment Multi Core Coaxial Cable For Ultrasound ...
Rosh3 X-Ray High Voltage Medical Equipment Electrical Electric Cable Wire Products are used in X-ray ...