Home Companies SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor

SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD

Contact Us

[China] country

Trade Verify

Address: No.8 Huamei Road,Songgang Sub-District,Baoan District, SHENZHEN, Guangdong 518000, China

Contact name:Coco

Inquir Now

SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor

Country/Region china
City & Province shenzhen guangdong
Categories Power Cables
InquireNow

Product Details

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor

 

Fire resistant cable Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Fire resistant cable Construction

1. Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

 

7.Constructions

Conductor : Plain annealed copper solid or stranded (class 1 or 2) conductor complying with BS EN 60228

Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃

Interlining: LSOH Flame Retardant Polyolefin, black

Armouring: SWA(Steel Wire Armouring)

Sheath : LSOH Flame Retardant Polyolefin, black

 

 

 

Product type Conductor structure(mm) Insulation thickness(mm) Sheath thickness(mm) Approx. cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.8 1.4 5.2 12.1
1×2.5 1 0.8 1.4 5.6 7.41
1×4 1 1.0 1.4 6.0 4.61
1×6 1 1.0 1.4 6.5 3.08
1×10 7 1.0 1.4 7.6 1.83
1×16 7 1.0 1.4 8.6 1.15
1×25 7 1.2 1.4 10.2 0.727
1×35 7 1.2 1.4 11.2 0.524
1×50 10 1.4 1.4 12.5 0.387
1×70 14 1.4 1.4 14.3 0.268
1×95 19 1.6 1.5 16.5 0.193
1×120 24 1.6 1.5 18.2 0.153
1×150 30 1.8 1.6 20.1 0.124
1×185 37 2.0 1.7 22.2 0.0991
1×240 48 2.2 1.8 24.9 0.0754
1×300 61 2.4 1.9 27.5 0.0601
1×400 61 2.6 2.0 30.8 0.0470

 

INSTALLATION METHOD DETAILS

 

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 0   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 1   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 2   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 3
A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
 
WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 4   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 5   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 6   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 7
B1 – Electroduct in brickwork (Single-core)   B1 – Electroduct in brickwork (multi-core)   C – On the wall    C – On the ceiling
             
WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 8   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 9   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 10   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 11
C – Non-perforated tray   F – Perforated tray (Single-core)   F – Perforated tray (multi-core)   F –Suspended (Single-core)
             
WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 12   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 13   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 14   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 15
E – Suspended (multi-core)   B2 – Construction space   B2 – Construction space   B1 – Electroduct (Single-core)
             
WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 16   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 17   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 18   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 19
B2 – Electroduct (Multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B1 – Ventilated raceway embedded in floor
             
WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 20   WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor 21        
C – Embedded in the brickwork   D – Buried in additional mechanical protection        

* Dimensions and specifications may be changed without prior notice.

▼ Standards&Certificates:
  International: IEC 60502-1
National:GB/ T 12706.1-2008

Packing&Delivery:

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

Copper Cable ZR YJV22 0.6/1kv XLPE Insulated Steel Tape Armoured FR PVC Underground Power Cable
▼ Cable Drum Data:

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 4 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300
 

 

▼ Delivery Port :

Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 5 Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 6 Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 7
Port of Shenzhen Port of Hongkong

Port of Guangzhou
 

 

▼ Technical parameters:

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.7 1.4 6.0 12.1
1×2.5 1 0.7 1.4 6.4 7.41
1×4 1 0.7 1.4 6.9 4.61
1×6 1 0.7 1.4 7.3 3.08
1×10 7 0.7 1.4 8.4 1.83
1×16 7 0.7 1.4 9.4 1.15
1×25 7 0.9 1.4 11.0 0.727
1×35 7 0.9 1.4 12.0 0.524
1×50 10 1.0 1.4 13.3 0.387
1×70 14 1.1 1.4 15.1 0.268
1×95 19 1.1 1.5 17.3 0.193
1×120 24 1.2 1.5 19.0 0.153
1×150 30 1.4 1.6 20.9 0.124
1×185 37 1.6 1.6 23.0 0.0991
1×240 48 1.7 1.7 25.7 0.0754
1×300 61 1.8 1.8 28.3 0.0601
1×400 61 2.0 1.9 31.6 0.0470
1×500 61 2.2 2.0 35.1 0.0366
1×630 61 2.4 2.2 42.1 0.0283

2. 2 Core&3 Core

 

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 0.7 1.8 10.6 12.1
2×2.5 1 0.7 1.8 11.4 7.41
2×4 1 0.7 1.8 12.4 4.61
2×6 1 0.7 1.8 13.2 3.08
2×10 7 0.7 1.8 15.4 1.83
2×16 7 0.7 1.8 17.4 1.15
2×25 7 0.9 1.8 20.6 0.727
2×35 7 0.9 1.8 22.6 0.524
2×50 10 1.0 1.8 26.2 0.387
2×70 14 1.1 1.8 29.8 0.268
2×95 19 1.1 1.9 34.0 0.193
2×120 24 1.2 2.0 37.4 0.153
2×150 30 1.4 2.2 41.2 0.124
2×185 37 1.6 2.3 45.6 0.0991
2×240 48 1.7 2.5 51.0 0.0754
2×300 61 1.8 2.6 56.0 0.0601
2×400 61 2.0 2.9 62.6 0.0470
2×500 61 2.2 3.1 70.0 0.0366
2×630 61 2.4 3.3 83.6 0.0283
3×1.5 1 0.7 1.8 11.2 12.1
3×2.5 1 0.7 1.8 12.1 7.41
3×4 1 0.7 1.8 13.2 4.61
3×6 1 0.7 1.8 14.0 3.08
3×10 7 0.7 1.8 16.4 1.83
3×16 7 0.7 1.8 18.6 1.15
3×25 7 0.9 1.8 22.0 0.727
3×35 7 0.9 1.8 24.2 0.524
3×50 10 1.0 1.8 28.0 0.387
3×70 14 1.1 1.9 32.1 0.268
3×95 19 1.1 2.0 36.4 0.193
3×120 24 1.2 2.1 40.3 0.153
3×150 30 1.4 2.3 44.3 0.124
3×185 37 1.6 2.4 49.1 0.0991
3×240 48 1.7 2.6 54.9 0.0754
3×300 61 1.8 2.7 60.1 0.0601
3×400 61 2.0 3.0 67.4 0.0470
3×500 61 2.2 3.2 75.3 0.0366
3×630 61 2.4 3.5 90.0 0.0283

3. 4 Core&5 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 1.8 12.2 12.1
4×2.5 1 0.7 1.8 13.1 7.41
4×4 1 0.7 1.8 14.3 4.61
4×6 1 0.7 1.8 15.3 3.08
4×10 7 0.7 1.8 18.0 1.83
4×16 7 0.7 1.8 20.4 1.15
4×25 7 0.9 1.8 24.3 0.727
4×35 7 0.9 1.8 26.7 0.524
4×50 10 1.0 1.8 30.8 0.387
4×70 14 1.1 2.0 35.4 0.268
4×95 19 1.1 2.1 40.4 0.193
4×120 24 1.2 2.3 44.9 0.153
4×150 30 1.4 2.4 49.3 0.124
4×185 37 1.6 2.6 54.7 0.0991
4×240 48 1.7 2.8 61.0 0.0754
4×300 61 1.8 3.0 67.2 0.0601
4×400 61 2.0 3.3 75.3 0.0470
4×500 61 2.2 3.5 84.0 0.0366
4×630 61 2.4 3.8 100.5 0.0283
5×1.5 1 0.7 1.8 13.2 12.1
5×2.5 1 0.7 1.8 14.2 7.41
5×4 1 0.7 1.8 15.6 4.61
5×6 1 0.7 1.8 16.7 3.08
5×10 7 0.7 1.8 19.6 1.83
5×16 7 0.7 1.8 22.3 1.15
5×25 7 0.9 1.8 26.7 0.727
5×35 7 0.9 1.8 29.4 0.524
5×50 10 1.0 1.9 34.1 0.387
5×70 14 1.1 2.1 39.1 0.268
5×95 19 1.1 2.2 44.7 0.193
5×120 24 1.2 2.4 49.7 0.153
5×150 30 1.4 2.6 54.7 0.124
5×185 37 1.6 2.8 60.6 0.0991
5×240 48 1.7 3.0 67.7 0.0754
5×300 61 1.8 3.2 74.6 0.0601
5×400 61 2.0 3.5 83.4 0.0470
5×500 61 2.2 3.8 93.4 0.0366
5×630 61 2.4 4.1 111.7 0.0283

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 0.7 1.8 12.9 7.41
3×4+1×2.5 1 0.7 1.8 14.0 4.61
3×6+1×4 1 0.7 1.8 15.1 3.08
3×10+1×6 7 0.7 1.8 17.3 1.83
3×16+1×10 7 0.7 1.8 19.8 1.15
3×25+1×16 7 0.9 1.8 23.3 0.727
3×35+1×16 7 0.9 1.8 25.1 0.524
3×50+1×25 10 1.0 1.8 29.4 0.387
3×70+1×35 14 1.1 1.9 33.5 0.268
3×95+1×50 19 1.1 2.1 38.1 0.193
3×120+1×70 24 1.2 2.2 42.5 0.153
3×150+1×70 30 1.4 2.3 45.8 0.124
3×185+1×95 37 1.6 2.5 51.2 0.0991
3×240+1×120 48 1.7 2.6 57.0 0.0754
3×300+1×150 61 1.8 2.8 62.6 0.0601
3×400+1×185 61 2.0 3.1 70.1 0.0470
3×500+1×240 61 2.2 3.3 78.3 0.0366
3×630+1×300 61 2.4 3.6 92.1 0.0283
3×2.5+2×1.5 1 0.7 1.8 13.8 7.41
3×4+2×2.5 1 0.7 1.8 15.1 4.61
3×6+2×4 1 0.7 1.8 16.2 3.08
3×10+2×6 7 0.7 1.8 18.5 1.83
3×16+2×10 7 0.7 1.8 21.3 1.15
3×25+2×16 7 0.9 1.8 24.9 0.727
3×35+2×16 7 0.9 1.8 26.6 0.524
3×50+2×25 10 1.0 1.8 31.4 0.387
3×70+2×35 14 1.1 2.0 35.6 0.268
3×95+2×50 19 1.1 2.1 40.4 0.193
3×120+2×70 24 1.2 2.3 45.5 0.153
3×150+2×70 30 1.4 2.4 48.5 0.124
3×185+2×95 37 1.6 2.5 54.2 0.0991
3×240+2×120 48 1.7 2.7 60.3 0.0754
3×300+2×150 61 1.8 2.9 66.5 0.0601
3×400+2×185 61 2.0 3.2 74.3 0.0470
3×500+2×240 61 2.2 3.5 83.1 0.0366
3×630+2×300 61 2.4 3.8 97.0 0.0283

Ordering Options:
For prompt quotation / supplies please make sure your inquiries and your orders are securing the following data :

1 International or Special Standard. (Alternatively, the precise usage of the cable.)
2 Rated voltage.
3 Copper or Aluminium conductors.
4 Size of each conductor.
5 Insulation material : PVC XLPE or others.
6 Number and identification of conductors.
7 Other requirements.
8 Packing.
9 Required delivery time.
10 Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

Hot Products

High Quality Copper Core Conductor Electric RVV 2x0.75MM 4x2.5MM 4x1.5MM2 Power Cable ▼Applications: ...
High Quality Copper Core Conductor Electric RVV 2x0.75MM 4x2.5MM 4x1.5MM2 Power Cable ▼Applications: ...
60227 IEC 53 (RVV) Ordinary PVC Extruded Jacket Cord 2-5 Conductors 0.75-2.5mm2 ▼ Construction: Core ...
Long Life Low Smoke Zero Halogen Cable Bare Copper Class 2 Conductor Low Smoke Halogen Free Cable ...
Long Life Low Smoke Zero Halogen Cable Bare Copper Class 2 Conductor Low Smoke Halogen Free Cable ...
Long Life Low Smoke Zero Halogen Cable Bare Copper Class 2 Conductor Low Smoke Halogen Free Cable ...