Home Companies SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD

YTTW RTTZ Flame Retardant Power Cable , 3×70+1×35MM2 Metallic Sheath Halogen Free Wire

SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD

Contact Us

[China] country

Trade Verify

Address: No.8 Huamei Road,Songgang Sub-District,Baoan District, SHENZHEN, Guangdong 518000, China

Contact name:Coco

Inquir Now

SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

YTTW RTTZ Flame Retardant Power Cable , 3×70+1×35MM2 Metallic Sheath Halogen Free Wire

Country/Region china
City & Province shenzhen guangdong
Categories Power Cables
InquireNow

Product Details

YTTW RTTZ Fire Retardant Cable Corrugated Copper Metallic Sheath CCC Approved

Mineral insulated Fire resistance cable

 

YTTW, YTTWY, RTTW, Mineral Insulated Cables, MICC Fire Resistant Cables, Mineral Insulated Copper Cables, BS 6387 Mineral Insulated Cables, GB/T 34926-2017 Mineral Insulated Cables.

▼ Cable Featurers:

 

— Flame Retardant
— High Operating Temperatures
— LSOH Halogen-free
— Great Mechanical Strength
— Competitive Installed Cost
— Public Places

 

Our DJX cables provide outstanding electrical and fire-proof properties, and are halogen free.


The design, construction and testing are compliant with international standard IEC60502 and testing standard EN 50200 (PH-90),with standing temperatures of 840 °C for 90 minutes, which means they are capable of remaining in working order despite the most extreme fire conditions. Hence they are known as FIRE RESISTANT cables.


This type of cable is made up of single and multi-cores 600/1000V cables Service Temperature 90°C Emergency Overload Temperature 105°C Short-Circuit Temperature 250°C


Installation of these cables is essential in safety circuits (detection and alarm circuits,evacuation and fire-fighting systems).

 

Cable structure
Conductor Stranded copper conductor class 2
Insulation mica tape1, flame retardant
Filler Glass yarns
core wraping Core wrapping with glass-fibre tape as flame-protection
Sheath Corrugated Copper
Outer covering (Optional) Anticorrosion Outer Sheath PVC
USAGE CHARACTERISTICS
Service Temperature 90°C
Emergency Overload Temperature 105°C
Short-Circuit Temperature 250°C
Laying Temperature should not be lower than 0°C
Minimum bending radius when laying Single core: r = 6 x cable outer diameter
Sheath colour The standard color is orange, other colors are available.

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×10 7 0.7 0.4 11.0 1.83
1×16 7 0.7 0.4 11.0 1.15
1×25 7 0.7 0.4 12.0 0.727
1×35 7 0.7 0.4 13.0 0.524
1×50 10 0.7 0.5 15.0 0.387
1×70 14 0.7 0.5 16.0 0.268
1×95 19 0.9 0.5 18.0 0.193
1×120 24 0.9 0.5 21.0 0.153
1×150 30 1.0 0.5 22.0 0.124
1×185 37 1.1 0.5 24.0 0.0991
1×240 48 1.1 0.6 28.0 0.0754
1×300 61 1.2 0.6 30.0 0.0601
1×400 61 1.4 0.6 33.0 0.0470

2. 2 Core&3 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 1.6 0.4 11.0 12.1
2×2.5 1 1.7 0.4 11.0 7.41
2×4 1 1.8 0.4 12.0 4.61
2×6 1 2.0 0.4 12.0 3.08
2×10 7 2.2 0.4 14.0 1.83
2×16 7 2.4 0.4 16.0 1.15
2×25 7 0.7 0.5 20.0 0.727
2×35 7 0.7 0.5 22.0 0.524
2×50 10 0.7 0.5 24.0 0.387
2×70 14 0.7 0.5 29.0 0.268
2×95 19 0.7 0.5 33.0 0.193
2×120 24 0.7 0.5 36.0 0.153
2×150 30 0.9 0.6 38.0 0.124
3×1.5 1 0.9 0.4 11.0 12.1
3×2.5 1 1.0 0.4 11.0 7.41
3×4 1 1.1 0.4 12.0 4.61
3×6 1 1.1 0.4 13.0 3.08
3×10 7 1.2 0.4 15.0 1.83
3×16 7 1.4 0.4 17.0 1.15
3×25 7 1.6 0.5 21.0 0.727
3×35 7 1.7 0.5 23.0 0.524
3×50 10 1.8 0.5 27.0 0.387
3×70 14 2.0 0.6 27.0 0.268
3×95 19 2.2 0.6 30.0 0.193
3×120 24 2.4 0.6 33.0 0.153
3×150 30 0.7 0.6 36.0 0.124

3. 4 Core&5 Core

 

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 0.4 11.0 12.1
4×2.5 1 0.7 0.4 12.0 7.41
4×4 1 0.7 0.4 13.0 4.61
4×6 1 0.7 0.4 14.0 3.08
4×10 7 0.7 0.5 17.0 1.83
4×16 7 0.9 0.5 20.0 1.15
4×25 7 0.9 0.5 23.0 0.727
4×35 7 1.0 0.5 26.0 0.524
4×50 10 1.1 0.5 30.0 0.387
4×70 14 1.1 0.6 31.0 0.268
4×95 19 1.2 0.6 34.0 0.193
4×120 24 1.4 0.6 37.0 0.153
4×150 30 1.6 0.6 41.0 0.124
5×1.5 1 1.7 0.4 12.0 12.1
5×2.5 1 1.8 0.4 13.0 7.41
5×4 1 2.0 0.4 14.0 4.61
5×6 1 2.2 0.4 16.0 3.08
5×10 7 2.4 0.5 19.0 1.83
5×16 7 0.7 0.5 22.0 1.15
5×25 7 0.7 0.5 26.0 0.727
5×35 7 0.7 0.5 29.0 0.524
5×50 10 0.7 0.5 32.0 0.387
5×70 14 0.7 0.6 34.0 0.268
5×95 19 0.7 0.6 38.0 0.193
5×120 24 0.9 0.6 42.0 0.153
5×150 30 0.9 0.6 46.0 0.124

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 1.0 0.4 12.0 7.41
3×4+1×2.5 1 1.1 0.4 13.0 4.61
3×6+1×4 1 1.1 0.4 14.0 3.08
3×10+1×6 7 1.2 0.5 16.0 1.83
3×16+1×10 7 1.4 0.5 20.0 1.15
3×25+1×16 7 1.6 0.5 23.0 0.727
3×35+1×16 7 1.7 0.5 24.0 0.524
3×50+1×25 10 1.8 0.5 28.0 0.387
3×70+1×35 14 2.0 0.6 31.0 0.268
3×95+1×50 19 2.2 0.6 34.0 0.193
3×120+1×70 24 2.4 0.6 37.0 0.153
3×150+1×70 30 0.7 0.6 40.0 0.124
3×2.5+2×1.5 1 0.7 0.4 12.0 7.41
3×4+2×2.5 1 0.7 0.4 14.0 4.61
3×6+2×4 1 0.7 0.4 15.0 3.08
3×10+2×6 7 0.7 0.5 17.0 1.83
3×16+2×10 7 0.9 0.5 21.0 1.15
3×25+2×16 7 0.9 0.5 24.0 0.727
3×35+2×16 7 1.0 0.5 26.0 0.524
3×50+2×25 10 1.1 0.6 30.0 0.387
3×70+2×35 14 1.1 0.6 33.0 0.268
3×95+2×50 19 1.2 0.6 37.0 0.193
3×120+2×70 24 1.4 0.6 40.0 0.153
3×150+2×70 30 1.6 0.6 44.0 0.124

5. 4+1 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×2.5+1×1.5 1 1.7 0.4 13.0 7.41
4×4+1×2.5 1 1.8 0.4 14.0 4.61
4×6+1×4 1 2.0 0.4 15.0 3.08
4×10+1×6 7 2.2 0.5 18.0 1.83
4×16+1×10 7 2.4 0.5 21.0 1.15
4×25+1×16 7 0.7 0.5 25.0 0.727
4×35+1×16 7 0.7 0.6 29.0 0.524
4×50+1×25 10 0.7 0.6 32.0 0.387
4×70+1×35 14 0.7 0.6 34.0 0.268
4×95+1×50 19 0.7 0.6 38.0 0.193
4×120+1×70 24 0.9 0.6 41.0 0.153
4×150+1×70 30 0.9 0.6 45.0 0.124
 
 
 

Packing&Delivery:

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

Copper Cable ZR YJV22 0.6/1kv XLPE Insulated Steel Tape Armoured FR PVC Underground Power Cable
▼ Cable Drum Data:

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 4 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300
 

 

▼ Delivery Port :

Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 5 Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 6 Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 7
Port of Shenzhen Port of Hongkong

Port of Guangzhou

 

Ordering Options:
For prompt quotation/supplies please make sure your inquiries and your orders are securing the following data :

1 International or Special Standard. (Alternatively, the precise usage of the cable.)
2 Rated voltage.
3 Copper or Aluminium conductors.
4 Size of each conductor.
5 Insulation material: PVC XLPE or others.
6 Number and identification of conductors.
7 Other requirements.
8 Packing.
9 Required delivery time.
10 Required validity.

If this all seems a little too technical for you, then why not get in touch with us. We look forward to assisting you in identifying the best products for your specific application and answering any questions you might have.

 

Hot Products

SJT SJTW Industrial Flexible Cable 3 Conductor 10 Awg Wire 500 Ft ▼ UL SJT 10AWG Thermoplastic ...
VDE CCC 3 Core Industrial Electrical Cable H03VV-F H05VV-F PVC ▼ Application: home.house Decoration...
UL 1007 30-16AWG Electric Wire Cable Single Core House Tinned Copper​ Factory Price UL 1007 30-16AWG ...
▼6242Y House Wiring Flat Twin+Earth Pure Copper Electric Wire Cable Flat PVC Insulation 1. Datas ...
Grey 6242y Insulated Electrical Cable For Harmonised Lighting ▼ TWIN & EARTH 6242Y FLAT PVC ...
6242y Multi Core Electrical Cable PVC Insulated EN 60228 Standards ▼ PVC Insulated and Sheathed Twin ...