Home Companies Guangzhou HongCe Equipment Co., Ltd.

IEC60669-1 Clause 19.3 Self Ballasted Lamp Load Box Power Meter Range 0-9KW

Guangzhou HongCe Equipment Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Room 202, Building 4-2, No. 539, Shibei Industrial Road, Dashi Street, Panyu District, Guangzhou, Guangdong

Contact name:Tessa Huang

Inquir Now

Guangzhou HongCe Equipment Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC60669-1 Clause 19.3 Self Ballasted Lamp Load Box Power Meter Range 0-9KW

Country/Region china
City & Province guangzhou guangdong
Categories Woodworking Machinery
InquireNow

Product Details

IEC60669-1 Clause 19.3 Self Ballasted Lamp Load Box, Power Meter Range 0-9KW

 

After these tests, it shall also be possible to make and break the switch by hand in the test circuit and the specimen shall not show:
– wear impairing further use;
– discrepancy between the position of the actuating member and that of the moving contacts, if the position of the actuating member is indicated;                Switch Tester
– deterioration of the enclosures, insulating lining or barriers to such an extent that the switch cannot be further operated or that it no longer complies with the requirements of Clause 10;
– loosening of electrical or mechanical connections;
– seepage of sealing compound;                                         Switch Tester
– relative displacement of the moving contacts of switches of pattern numbers 2, 3 or 6/2.
Breakage of the replaceable pull cord not involving the part entering the cord-operated switch shall not be considered a failure to pass the test.

 

Standard: IEC60669-1:2017 clause 19.3

Application: This device is suitable for breaking capacity and normal operation life test to fixed switches for house held and similar purpose, especially suitable for self ballast lamp switch electric stress and thermal stress test when control the LED circuit. To verify whether the switch can withstand normal use, any mechanical damage or electrical fatigue failure under normal operation, any contact adhesion phenomenon or long term closure or disconnection phenomenon, to test whether excessive wear or other harmful consequences.

Test sample: Self Ballast Lamp(SBL) Switches

Feature: Dimension about: wide (800mm) * Deep (800mm) * high (1800mm). The frame is blue and the side panels are light white. Above the front is the operation control panel. On the control there are power switch, product test voltage and power display instruments, alarms, touch screen, etc., there are resistors and capacitor load combinations, AC contactors, relays. There is a terminal under the box, which is connected to the product in the testing machine through the wire, and outputs current and provides load in the inspection process.

The load device has been preset with standard load conditions before shipment. As long as the test voltage is adjusted to 250V~, the operator presses the switch button with the same rated current as the switch to be tested, and its rated power, impulse waveform, Ipeak and I2t meet the corresponding requirements of the standard.

There are 3 stations and 3 switches can be tested at the same time.                   Switch Tester

With metering mode and metering dedicated port, built-in 90-degree closing plate, easy to measure the output waveform, Ipeak current value and I2t energy value, fully meet the standards for equipment measurement requirements.

The device is equipped with a voltage regulator, which can reach the voltage of 250V required by the switch test without the need of an external voltage regulator.

Parameters:

NO.ItemParameter
1Power supplysingle phase AC220V±5%/50Hz
2Voltage meter0 ~ 300V, precision 0.5, digital display
3Power meter0~9KW, precision 0.5, digital display
4Output channel3
5preset switch rated voltage250V
6rated current0A, 13A, 16A, 20A optional (can be customized test voltage and Test current)
7input voltageAdjustable, to ensure that the test voltage is 250V
8All operating parameters are set at 250V~, including W, Ipeak, I2t, and inrush current waveforms
9Each device provides a closing control device (touch screen select "measurement" function),each time is in the 90 degree angle conduction, this function can be used for initial equipment calibration and measurement verification.
10With long / long protection function, the protection time of 1 ~ 99S can be preset, shutdown alarm protection.
11

Use environment: temperature 5 ~ 40 °C, relative humidity 20 ~ 90% RH, atmospheric pressure 80 ~ 106kpa. No severe vibration, no electromagnetic interference, no dust, corrosive gas, good heat dissipation.

 

 

Picture for reference:

Hot Products

Stainless Steel Inner Wall IEC Test Equipment 8 - 20 Times/Hour Air Changes IEC Description: The ...
48rpm Label Marking Abrasion Test Machine 220VAC 50Hz Markings Durability Tester Abrasion Test ...
GB/T531-1999 Digital Shore Hardness Gauge Measuring Range 0~100HD IEC 60335-2-80 Clause 20 stability ...
IEC60990 Figure 4 Touch Current Measuring Network Convenient Products Introduction: This test ...
Thermal Ageing Oven IEC 60811 Testing Equipment Air Changes Rate 5-20 Times Per Hour Thermal Ageing ...
IEC 60228 Conductor resistance meter Product Introduction: CXT2510 Ultra low DC resistance tester is ...