Guangzhou HongCe Equipment Co., Ltd. |
Verified Suppliers
|
|
IEC60884-1 Figure 11 Conductor Cable Tensile Test Clamping Device
Application:
Terminals with screw clamping shall be so designed and constructed that they clamp the conductor(s) without undue damage to the conductor(s).
Appliance is apparatus of checking damage. The terminal is placed
in the test apparatus according to tester and fitted with rigid,
solid, stranded and/or flexible conductor(s), according to
standard first with the smallest and then with the largest
nominal cross-sectional area, the clamping screw(s) or nut(s) being
tightened with the torque according to standard.
The length of the test conductor shall be 75 mm longer than the
height (H) specified in standard.
The end of the conductor is passed through an appropriate bushing
in a plate positioned at a height (H) below the equipment, as given
in standard. The bushing is positioned in a horizontal plane such
that its centre line describes a circle of 75 mm diameter,
concentric with the centre of the clamping unit in the horizontal
plane; the platen is then rotated at a rate of (10 ± 2) r/min.
The distance between the mouth of the clamping unit and the upper
surface of the bushing shall be within ±15 mm of the height
specified in standard. The bushing may be lubricated to prevent
binding, twisting, or rotation of the insulated conductor.
A mass as specified in standard is suspended from the end of
the conductor. The duration of the test is approximately 15 min.
During the test, the conductor shall neither slip out of the
clamping unit nor break near the clamping unit, nor shall the
conductor be damaged in such a way as to render it unfit for
further use.
Technical parameters:
Power Supply: 220V 50Hz or 115V 60Hz
The range of counting number: 1~9999(150 times(15 min) is by
default.
Rate of Testing: (10±2)r/min
Weight: 300g/400g/700g/900g/1400g/2000g*1(it can be customized)
Diameter of gyration:75mm
Diameter of bushing hole (mm): 6.5,9.5,13,14.5(it can be
customized)
Height(H)(mm): 260,280,300,320mm
Conforms to standard: IEC60884Figure11,VDE0620,IEC60947.1 Figure 1
Nominal cross-sectional area of conductor ( mm²) | Diameter of bushing Hole( mm) | Height (mm) | Mass for conductor (kg) |
0.5 | 6.5 | 260 | 0.3 |
0.75 | 6.5 | 260 | 0.4 |
1.0 | 6.5 | 260 | 0.4 |
1.5 | 6.5 | 260 | 0.4 |
2.5 | 9.5 | 280 | 0.7 |
4.0 | 9.5 | 280 | 0.9 |
6.0 | 9.5 | 280 | 1.4 |
10.0 | 9.5 | 280 | 2.0 |
16.0 | 13.0 | 300 | 2.9 |
25.0 | 13.0 | 300 | 4.5 |
35 | 14.5 | 320 | 6.8 |
1, The height:±15mm. 2, If the bushing-hole diameter is not large enough, you can choose the larger one. |