Guangzhou Jin Lun Electric Equipment Co.,Ltd |
|
Air to Water Heating System Monobloc Air Source Heat Pump heating 5KW
Technology Specification
AIR SOURCE HEAT PUMP FEATURE
»Indoor unit mainly includes condenser, 4-way valve and expansion valve.
» Outdoor unit comprises evaporator, fan and compressor.
»Auxiliary electronic heater or solar coiler is on your option
» Fashionable design, compact structure, saving the place.
»Quiet, lower the noise when the unit is running
»Advance control panel. Timer function , automatic defrosting function, optional electrical heating, error messages showed for warning.
»It can be work in -25°C low ambient temperature.
Hot water output temperature up to 60°C, for domestic hot water or heating.
auto-defrosting function included. And cooling is optional
Cooperate Paratner
.
A. Payment service
1. T/T
2. L/C (for container order only)
B. Technical service
1. We calculate the capacity and recommend the best models.
2.We supply you the professional refrigeration technical support and electronic technical support for your installation, debugging and operation.
3. We supply the spare parts and technical support in and after the warranty time.
4. We supply the training course to your workers at our factory if you need.
5. We can offer site training to your workers in your place which is negotiable.
C. After-sales service
1. Technical support for your installation, operation and maintenance.
2. Standard warranty time: One years’warranty for heat pumps
You can also pay for extended warranty or we can renegotiate the longer warranty period.
3. Spare parts and technical support at most economic prices after the warranty.
FAQ
Why us?
1. Timely Delivery, considerate sales after service
2. Many Years quality warranty,OEM service.
3. Top Craftmanship, All products 100% tested
4. Preferential freight by Famous shipping company
5. New Design,Very popular style products recommendation for your local market
Packaging & Shipment
1> Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.
2> Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen during rude transporattion .
3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.
4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.
5>Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)
Packaging Details :Standard export packing -with plywoods case packages,OEM is available for Factory price heat pump water heaters
Delivery Time :15 work days after arrival of down payment
ErP Energy label:
MODEL | Unit | MD10D | |
Rated heating capacity | KW | 3.5 | |
Rated Cooling capacity | 1.8 | ||
Hot water supply | L/h | 75 | |
Average heating input power | KW | 0.75 | |
Rated heating input current | A | 6 | |
Rate outlet water temp | ℃ | 55 | |
COP | 3.65 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 1000L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 29 | |
MODEL | Unit | MD15D | |
Rated heating capacity | KW | 5 | |
Rated Cooling capacity | 3 | ||
Hot water supply | L/h | 100 | |
Average heating input power | KW | 1.25 | |
Rated heating input current | A | 6 | |
Rate outlet water temp | ℃ | 55 | |
COP | 3.65 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 1600L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 40 | |
MODEL | Unit | MD20D | |
Rated heating capacity | KW | 7 | |
Rated Cooling capacity | 5 | ||
Hot water supply | L/h | 150 | |
Average heating input power | KW | 1.84 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 60 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A//R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 2000L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 55 | |
MODEL | Unit | MD30D | |
Rated heating capacity | KW | 12 | |
Rated Cooling capacity | 7 | ||
Hot water supply | L/h | 260 | |
Average heating input power | KW | 3 | |
Rated heating input current | A | 13/6 | |
Max outlet water temp | ℃ | 60 | |
COP | 4 | ||
Power | V/Hz | 220V/380/50 | |
Noise | Db(a) | 54 | |
Dimension | W*D*H | mm | 1120*490*710mm |
Packing size | W*D*H | mm | 1190*520*865mm |
Unit weight | KG | 108 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 3000L/h | |
Water pressure down | Kpa | 40 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 100 | |
MODEL | Unit | MD40D | |
Rated heating capacity | KW | 16 | |
Rated Cooling capacity | 10 | ||
Hot water supply | L/h | 360 | |
Average heating input power | KW | 4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 4000L/h | |
Water pressure down | Kpa | 45 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 125 | |
MODEL | Unit | MD50D | |
Rated heating capacity | KW | 18 | |
Rated Cooling capacity | 12 | ||
Hot water supply | L/h | 400 | |
Average heating input power | KW | 4.4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | C | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 5000L/h | |
Water pressure down | Kpa | 45 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 150 | |
MODEL | Unit | MD60D | |
Rated heating capacity | KW | 21 | |
Rated Cooling capacity | 15 | ||
Hot water supply | L/h | 520 | |
Average heating input power | KW | 5.68 | |
Rated heating input current | A | 12 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 210 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 6000 | |
Water pressure down | Kpa | 48 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 175 | |
MODEL | Unit | MD100D | |
Rated heating capacity | KW | 36 | |
Rated Cooling capacity | 24 | ||
Hot water supply | L/h | 800 | |
Average heating input power | KW | 9.2 | |
Rated heating input current | A | 18 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*800*1230 |
Unit weight | KG | 289 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 10000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size | DN | 32 | |
Max flat square meter | M2 | 300 | |
MODEL | Unit | MD150D | |
Rated heating capacity | KW | 42 | |
Rated Cooling capacity | 29 | ||
Hot water supply | L/h | 1200 | |
Average heating input power | KW | 11 | |
Rated heating input current | A | 18 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*800*1230 |
Unit weight | KG | 320 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 15000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size | DN | 32 | |
Max flat square meter | M2 | 350 | |
MODEL | Unit | MD200D | |
Rated heating capacity | KW | 72 | |
Rated Cooling capacity | 48 | ||
Hot water supply | L/h | 1590 | |
Average heating input power | KW | 18.2 | |
Rated heating input current | A | 35 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 65 | |
Dimension | W*D*H | mm | 2040×1100×2000 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 20000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size | DN | 50 | |
Max flat square meter | M2 | 600 | |
MODEL | Unit | MD300D | |
Rated heating capacity | KW | 88 | |
Rated Cooling capacity | 65 | ||
Hot water supply | L/h | 24000 | |
Average heating input power | KW | 25 | |
Rated heating input current | A | 45 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 68 | |
Dimension | W*D*H | mm | 2040×1100×2000 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 30000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size | DN | 50 | |
Max flat square meter | M2 | 730 |
Air to water source hat pump working principle diagarm