digital hydraulic speed governor for hydro turbine generator

 

Based on Automation products, Smart Control* Turbine Speed Governors can regulate any type of turbine with any power output. They integrate seamlessly into the Smart Control Distributed Control System. Only one engineering tool is therefore needed, helping simplify software management, licensing, upgrades and training. 

They feature compact and modular plug-and-play hardware for easy installation and maintenance. Intuitive software, with advanced functions derived from more than 20 years of Hongya power’s hydro experience, enhances turbine processes, helping refine plant operation and reduce machine wear.

The Smart Control* Governor’s features for specific turbine types include blade discretizer for Bulb and Kaplan turbines, individual wicket gate control for Pump turbines and a jet dispatcher for Pelton turbines. With simplex or redundant configurations and a rugged design, SmartControl* Governor can operate in harsh conditions with electromagnetic interference, vibration, humidity and oil. 

 

specification

 

Place of Origin:Sichuan, China
Brand Name:Customized
Warranty:1 year
Application:Hydropower Plant
Certificate:ISO9001
 

 

working parameters

  1. AC power AC110V±15% or AC220V±15% 50Hz or 60Hz
  2. DC power DC110V±15% or DC220V±15%
  3. Genset frequency signal AC0.25-200V (supplied by Genset PT) or gear signal
  4. Network frequency signal AC0.25-200V (supplied by network PT)
  5. Active power -10V- +10V or 0(4)-20mA

PID parameters 

  1. Proportional gain (Kp) 0-20(times) (resolution 0.1)
  2. Integral gain (Ki) 0-10(1/s) (resolution 0.01)
  3. Differential gain (Kd) 0-5.0(s) (resolution 0.1)
  4. Permanent speed droop (bp) 0-10(%) (resolution 0.1%)
  5. Frequency setting (Fs) 45-55(Hz) (resolution 0.01Hz)
  6. Gate opening setting (Gs) 0-100(%) (resolution 0.1%)
  7. Output setting (Ps) 0-120(%) (resolution 0.1%)
  8. Electric limit opening setting (Le) 0-100(%) (resolution 0.1%)
  9. Artificial frequency dead-band (Fa) 0-±0.5(Hz) (resolution 0.01Hz)

Hot Products

Product Description: Francis Hydro Turbine The Francis Hydro Turbine is a highly efficient and ...
Product Description: Features: Product Name: Francis Hydro Turbine Rated Flow: 0.3-100m3/s Rated ...
Product Description: Francis Hydro Turbine - Efficient and Powerful The Francis Hydro Turbine is a ...
Product Description: Francis Hydro Turbine The Francis Hydro Turbine is a cutting-edge water turbine ...
Product Description: Francis Hydro Turbine - A Modern Francis Turbine for Efficient Hydropower ...
Product Description: Francis Hydro Turbine - Product Overview The Francis Hydro Turbine, manufacture...