ZW32-12 Series Pole Mounted Automatic Circuit Breaker Easy Operation GB1984 / GB11022 With Outdoor Disconnect Switch

Country/Region china
Categories Manufacturing & Processing Machinery Processing Services
InquireNow

Product Details

ZW32-12 Series Pole Mounted Automatic Circuit Breaker Easy Operation GB1984 / GB11022 With Outdoor Disconnect Switch

 

 

Product Description:


 

ZW32-12 pole mounted circuit breaker is a fixed voltage 12KV, three-phase AC 50Hz outdoor distribution equipment. It is mainly used for breaking and closing load current, overload current and short circuit current. The utility model is suitable for the protection and control in the distribution system of substations and industrial and mining enterprises, and the places where the rural power grid operates frequently. It can also operate the segmented switch of the power grid, and after installing the controller, it can realize the automation of the distribution network.

 

GW9-10 high voltage disconnect switch is an electrical switch that is designed to isolate a section of an electrical network or system from the rest of the system for maintenance or repair purposes. It is typically used in high voltage power transmission and distribution systems.

The switch is designed to open and close under normal or abnormal conditions, such as a fault or overcurrent. When the switch is open, it physically disconnects the section of the system from the rest of the network, preventing the flow of electricity to that section.

High voltage disconnect switches are typically designed to operate at voltages between 600 volts and 765,000 volts, and they can be operated manually or automatically. They are typically installed in substations or on power poles, and they are an important component of the electrical grid infrastructure.

 

double effect of using when the circuit breakers used with isolation disconnector!!

 

 

 

Structure:


 

1.Frame: The frame serves as the main structural component of the circuit breaker, providing support and housing for the internal components.

2.Current Carrying Components: These components include the contacts, conductors, and current-carrying parts that form the electrical path through the circuit breaker. They are responsible for conducting and interrupting the flow of current.

3.Permanent Magnet Assembly: The permanent magnet assembly is a crucial component of the circuit breaker. It consists of permanent magnets that generate a magnetic field to control the tripping action of the circuit breaker. The magnets are carefully positioned to provide the desired magnetic force for efficient and precise operation.

4.Tripping Mechanism: The tripping mechanism is responsible for initiating the opening of the circuit breaker when a fault or overload condition is detected. In an Intelligent Permanent Magnetic Circuit Breaker, the tripping mechanism is designed to respond rapidly and accurately to the fault signals received from the intelligent control system.

5.Intelligent Control System: The intelligent control system is the brain of the circuit breaker. It typically includes microprocessors, sensors, and other electronic components that monitor electrical parameters, analyze fault conditions, and control the operation of the circuit breaker. The control system may also feature communication interfaces for remote monitoring, data logging, and integration with other systems.

6.Auxiliary Components: Various auxiliary components may be present in an Intelligent Permanent Magnetic Circuit Breaker, depending on the specific application and requirements. These can include indicators, auxiliary contacts for signaling and control purposes, mechanical interlocks, and terminals for external wiring connections.

7.Enclosure: The circuit breaker is typically enclosed within a housing to provide protection against environmental factors, such as dust, moisture, and physical damage. The enclosure may be made of durable materials like metal or high-quality plastics.

 

 

 

Feature:


 

1.Three-phase pillar-type fully enclosed structure with high sealing performance.

A.Stable and reliable breaking performance, no combustion or explosion hazards; maintenance-free, small size, lightweight, and long service life.

B.Strong moisture and dew prevention performance, especially suitable for use in cold or humid areas.

C.Imported materials with good insulation performance, high temperature resistance, UV resistance, and aging resistance.

2.Efficient and reliable miniaturized spring operating mechanism.

A.The energy storage motor has low power consumption for opening and closing operations; the mechanism adopts a direct transmission method with fewer components, resulting in high reliability.

B.The operating mechanism is placed in a sealed box to effectively prevent rust and improve the reliability of the mechanism.

3.Convenient and flexible control and free combination performance.

A.It can be manually operated for breaking or electrically operated for opening and closing, as well as remotely controlled from a remote location.

B.It can be paired with an intelligent controller to achieve distribution automation or combined with a recloser controller to form an automatic recloser or sectionalizer.

C.It can be equipped with two-phase or three-phase current transformers for overcurrent or short circuit protection.

D.It can provide current acquisition signals for intelligent controllers and can be equipped with metering current transformers according to user requirements.

E.It can be equipped with a three-phase interlocking isolation switch with a built-in anti-misoperation interlocking device; it can also be installed with surge arrester pillar insulators for easy maintenance.

 

 

 

Application:


 

1.Substations: It is commonly used in both indoor and outdoor substations for protection and control of medium-voltage power distribution. The vacuum circuit breaker ensures reliable interruption of fault currents, overload currents, and load currents, safeguarding the substation equipment.

2.Industrial and mining enterprises: The ZW32-12 vacuum circuit breaker is employed in the distribution systems of industrial and mining enterprises to protect motors, transformers, and other electrical equipment from overcurrents and short circuits. It helps maintain the stability and safety of the power supply in these facilities.

3.Rural power grids: Due to its ability to withstand frequent operations, the vacuum circuit breaker is suitable for application in rural power grids. It can be used as a sectional switch, allowing for efficient segmentation of the power grid. Additionally, when equipped with a controller, it enables automation of the distribution network, improving the reliability and efficiency of the rural power system.

4.Commercial buildings: The vacuum circuit breaker is also utilized in commercial buildings for power distribution and protection. It ensures safe and reliable operation of electrical systems, preventing damage to equipment and minimizing downtime.

 

 

 

Technical Parameter:


 

ZW32-12

Serial No.ParameterUnitData
1Rated voltagekV12
2Insulation level of FractureWorking Frequency(Dry Test/Wet Test)48
Voltage of Lightning Shock Test (Peak)85
3Level of Insulation to ground/phase to phaseWorking FrequencyDry Test42
Wet Test34
Voltage of Lightning Shock Test (Peak)75
4Rated CurrentA630
5Rated thermal stability current (Effective value)kA20
6Rated short-circuit breaking current (Effective value)25
7Rated thermal stability times4
8Rated short-circuit closing current(Peak)kA63
9Rated dynamic stability current (Peak)
10Mechanical lifetimetimes10000
11Opening rated current1000
12Surrounding air temperatureHighest Temperature-55
Lowest Temperature+60
Difference ofMaximum daily temperatureK≤25
13Altitudem≤2500
14HumidityAverage of daily relative humidity%≤95
Average of monthly relative humidity≤90
15Earthquake-resistant capacityHorizontal accelerationg0.25
Ground vertical acceleration0.125
Safety Factor/1.67
16Wind Speedm/s≤35
17Ice Thicknessmm≤20

 

GW9-10

Serial No.ParameterUnitData
1Rated VoltagekV12
2Rated CurrentModel No.(H)GW9-12(W)/630-20A630
(H)GW9-12(W)/1000-201000
(H)GW9-12(W)/1250-31.51250
34s Short-time withstanding currentModel No.(H)GW9-12(W)/630-20kA50
(H)GW9-12(W)/1000-2050
(H)GW9-12(W)/1250-31.580
4Rated Insulation LevelLightning surge withstand voltage(peak)Polar-to-Earth
(Positive & Negative)
kV75
Interfracture
(Positive & Negative)
85
Industrial frequency withstand voltage
(1 min)
(Effective value)
Dry Test/Wet TestPolar-to-Earth42(Dry)
34(Wet)
Interfracture48(Dry)
48(Dry)
48(Dry)
40(Wet)
5Main Circuit Resistanceμ Ω630
1000
1250
6Mechanical Life Timetimes50
50
80

 

 

 

 

 

 

Hot Products

Outdoor Intelligent Pole Mounted Circuit Breaker With Zero-Sequence Sensors Permanent Magnetic ...
Pole Mounted Circuit Breaker Fixed Installation Automatic Reset Mode Operated With High Voltage ...
Outdoor Distribution HV Pole Mounted Circuit Breaker With Controller Of Smart System Matching With ...
AC Pole Mounted Circuit Breaker High Voltage High Efficiency With Smart Controller Auto Reset Vacuum ...
Light Weight Vacuum Pole Mounted Circuit Breaker With Zero-Sequence Sensors And Controller Outdoor ...
15kV HV Pole Mounted Circuit Breaker Automatic Reset Circuit Breaker For Distribution System With ...