Cross Hatch Cutter

Product Introduction:

2202 Cross Hatch Cutter is designed and manufactured according to ISO 2409-1992, GB/T9286-98, BS 3900 E6 and ASTM D3359 standards.

Introduction:

2202 Cross Hatch Cutter is designed and manufactured according to ISO 2409-1992, GB/T9286-98, BS 3900 E6 and ASTM D3359 standards.

Technical Specification:

Cutting Head No.Gap(mm)BladesCutters EdgesCoating Thickness(µm)
2202/11680~60
2202/211180~60
2202/31.5680~60
2202/426861~120
2202/6368121~250

Order Information :

Standard KitContain
2202/1CCross Hatch Cutter
+
Carry Case
+
Hexagonal Screwdriver
+
Brush
+
Magnifier
+
Tape
2202/2C
2202/3C
2202/4C
2202/6C
Simple KitContain
2202/1SCross Hatch Cutter
+
Paper Box
+
Hexagonal Screwdriver
2202/2S
2202/3S
2202/4S
2202/6S

Evaluation Criteria of Coating Adhesion Test:

Evaluation according to scale below:

DescriptionPerformanceClass(ASTM)Class(ISO)
The edges of the cuts are completely smooth; none of the squares of the lattice is detached 5B0
Detachment of small flakes of the coating at the intersections of cuts. A cross-cut area not significantly greater than 5% is affected4B1
The coating has flaked along the edges and/or at the intersections of the cuts. A cut area significantly greater than 5%, but not significantly greater than 15% is affected3B2
The coating has flaked along the edges of the cuts partly or wholly in large ribbons, and or it has flaked partly or wholly on different parts of the squares. A cross cut area significant greater than 35% is affected2B3
The coating has flaked along the edges of the cuts in large ribbons and/or same square have detached parity or wholly. A cross-cut area significantly greater than 35%, but not significantly greater than 60% is affected1B4
Any degree of flaking that cannot even be classified 0B5

Hot Products

Elevator Wire Rope Detector Steel Rope Wire Rope Internal External Flaw Detector HRD-150 Elevator ...
Mining Ropes Wire Rope Flaw Detector Cableway Elevator Wire Rope Flaw Detector Steel Rope Flaw ...
WRT Magnetic Rope Detector Steel Rope Wire Rope Internal External Flaw Detector HRD-100 1. ...
WRT Magnetic Rope Detector Steel Rope Wire Rope Internal External Flaw Detector HRD-100 1. ...
WRT Magnetic Rope Detector Steel Rope Wire Rope Internal External Flaw Detector HRD-100 Elevator ...
Steel Wire Rope Flaw Tester Steel Rope Steel Wire Rope Internal External Detector HRD-100 Specificat...