288V 125A Relay BMS 16S HV Master BMS Home Energy Management System
 
 
  • 288V125Amp


    •  

     

    Communication protocol:
    Rs485, CAN, LAN, dry contact, Modbus

    * 3U standard 19inch case

    * Efficient, stable and reliable

    * size:W482*H132*D500mm

     

    12S-24S BMU(Slave)

    12S-24S BMU has 8pcs of tempreture sensors, Fan voltage 48V(17S-24S 12V), voltage detection range 0-5V,12V power
    supply,consumption less 20mA, CAN2.0 B communication

    Wire harness-Signal acquisition wire

    18 Pin+20Pin wire, standard length is 600mm,900mm,1200mmtempreture sensor wire: standard length is 600mm,900mm,1200mm
    Fan wire: 600mm
     
     

    Wire harness-communication wire

    Communication wire is connecting from master BMS to each BMU with cascade connection, the last port is for terminal resistance

     

     

    • Advanced Battery Management System --- The highly integrated battery management system enables seamless monitoring.
    •  
    • Perfect self-test and operational status detection, with HMI display, system operation information at a glance.
    •  
    • Perfect and reliable system control and protection strategies to fully protect the battery safety, extend the life of the battery escort. 
    •  
    • Modular design, configurable, scalable --- flexible combination of multiple energy storage unit
    •  
    • Can be expanded to a larger energy storage system, the maximum can support 272 (lead-carbon battery 400) battery series.
    •  
    • Capacity is large --- Built-in large-capacity memory chips can store a large number of key operational data, but also can install an SD card for offline access.
    •  
    • PCS has a protocol control function, the choice of circuit breaker version .
    •  
    • Rich communication interface --- multiple RS485, CAN, Ethernet, dry contact input and output interfaces, support for most of the market with PCS, monitoring server communication.
    •  
    • PCS without protocol control function, the choice of contactor + breaker version.
    •  
    • Automatic circulation control and automatic parallel machine off-line control, can be easily Parallel battery. (Model suffix selection D).
     
     
    3U BMS for ESS
     
    192V-600V, 125A-160A
     
    Support multiple BMS in parallel to achieve larger capacity
     

     

    Specification    
    Product Name
    BMS
    Model no.
    RBMS07S2-0-250A288V
    protecting method
    MCCB+Contactor
    Rated Current range
    -250A~250A
    Voltage Range
    144V-288V
    Current Sampling Accuracy
    1.0%FSR
    Communication interface with BMU
    RS485/CAN
    Communication interface with BMU
    CAN
    Communication interface with BMU
    RS485/CAN
    Communication with monitoring software/EMS
    Ethernet
    Support IAP upgrade
    Yes
    Support HMI display and parameter
    No(Optional plug in)
    Insulation detection
    Yes(Optional)
    High voltage power module
    Support DC start (optional)
    Dry contact output (normally open)
    No
    Maximum qty of BMUs
    20
    Power
    24VDC(18~28V)
    Power consumption
    ≤20W
    Size(W*H*D)mm
    4U (440*178*600)
    Way out
    Front
    Center Tap
    Support(Optional)
    Net weight
    23kg

     

     

    Safety Precautions

    • Tools for installation and commissioning personnel must be insulated
    • Insulation rubber gloves must be worn during the installation and maintenance. Wear goggles and insulating rubber Boots as the case may be to avoid the possible safety accidents.
    • Installation, commissioning and maintenance of the thread metal generated in the process, such as dropped into the battery, be sure to use an insulating tool to remove, you can not be lingering debris.
    • When maintenance is required, the main circuit breaker of the CBMS must be disconnected to cut off the connection of the battery pack to the PCS DC bus.
    • According to project requirements, parameters such as charge and discharge current and charge and discharge voltage of the battery management system have been set during initial
    • Document number installation and debugging. Parameters may not be changed without authorization. Otherwise, the battery life may be shortened, and more serious battery may be damaged Cause serious harm to safety accidents
    • In case of fire around the energy storage cabinet, be sure to use dry powder fire extinguishers or fire extinguishing sand. Fire extinguishing with liquid may cause electric shock.
    • If the system is not used for a long time, be sure to disconnect the main circuit breaker of the battery cabinet
    • Try to avoid long-term use in the following working environment:
    • Exceeds the temperature or humidity range specified in the specification
    • Strong vibration or vulnerable to impact of the place
    • Direct sunlight or near the heat source of the place
    • Dust, corrosive substances, flammable, high salt spray place

     

    CBMS Sample Drawing Of Standard Produsts 

     

     

     

    Our comapny 


    We are a company with many years experience in Battery Management Systems, making them work for our customers, ensuring that their systems are operating with greater efficiency and therefore benefit from optimum energy performance and increased comfort levels.

    We utilise intelligent programming and our skilled engineering team are trained to understand how to achieve this.


    No separate energy monitoring system or complex interface required.


    BMS staff are very knowledgeable and approachable and can diagnose problems quickly. They are very professional in communication issues to us and our clients.

     

     
    Application Scenarios 
     
    ◎ Battery Energy Storage System(BESS)
    ◎ Off-grid energy storage
    ◎ Data Center
    ◎ Grid frequency modulation energy storage
    ◎ Track power / traction
    ◎ LFP UPS power supply

     

     

    Hot Products

    Lifepo4 BMS 75S240V 50A Integrated BMS for UPS ESS Solar Off-Grid BESS Solar Home ESS Micro Grid ESS ...
    30-60S 50Amp Communication protocol: CAN, RS485, Bluetooth, GPRS,Dry Contact * Design: Master & ...
    Parallel Loop Current Control High Voltage Lithium Battery Management System Support For Short ...
    HV BMS GCE358 300Ah/200Ah LiFePo4 Battery Management System Master BMS for LiFePo4 BESS UPS off Grid ...
    High Voltage BMS Lifepo4 Battery Management System GCE master slave Lithium BMS 150S480V(+-240V) ...
    High-Voltage BMS 480V 400A LiFePo4 BMS Energy Storage Lithium Battery Management System BESS UPS ...