Home Companies Beijing HiYi Technology Co., Ltd

LH-DO59 Digital 12vdc Dissolved Oxygen Sensor Measuring Range 0~20mg/L 0~ 200.0%

Beijing HiYi Technology Co., Ltd

Contact Us

Trade Verify

Address: Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China

Contact name:Lisa Niu

Inquir Now

Beijing HiYi Technology Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

LH-DO59 Digital 12vdc Dissolved Oxygen Sensor Measuring Range 0~20mg/L 0~ 200.0%

City & Province beijing beijing
InquireNow

Product Details

LH-DO59 Digital Dissolved Oxygen Sensor

 

OVERVIEW

 

This sensor is based on polarography to measure dissolved oxygen in water. The dissolved oxygen sensor is composed of cathode and anode. The cathode is platinum electrode and the anode is silver / silver chloride electrode. The cathode and anode are immersed in the electrolyte chamber, which is isolated from the external measurement environment through a diaphragm. Dissolved oxygen diffuses to the cathode through the diaphragm and is reduced on the cathode to generate current. The reduction current is positive with the transfer rate of dissolved oxygen into the electrolyte. At a given temperature, the current is proportional to the partial pressure of oxygen in the water.

 

FEATURES & BENEFITS

 

• Adopt the principle of polarography, the test water sample needs to maintain fluidity.

• With appropriate oxygen permeable membrane, reference electrode and electrolyte, the electrode has better measurement accuracy and stability.

• Built in temperature sensor with automatic water temperature compensation function.

• Supports MODBUS / RS485 output.

 

APPLICATION

 

It can be used for the determination of dissolved oxygen in aquaculture river monitoring, sewage treatment, swimming pool and other water.

 

 

SPECIFICATIONS

 

ProjectSpecifications
Sensor materialPlatinum cathode, silver/silver chloride reference electrode
Working condition0 ~ 40°C
Temperature elementNTC10K
Response time≤90s
Measuring range0~20mg/L,0~ 200.0%
Installation mode5/4" NPT thread, flow-through or submersible mount
CableStandard 5 meters (OEM available)
Measuring principleTwo electrode polarography
Calibration2 points calibration
Storage temperature0 ~ 50°C (Dry without electrolyte)
Power supply12-24VDC
Data outputMODBUS/RS485
IP gradeIP68

 

 

 

Hot Products

KANE458s Flue Gas Analyser with direct CO2, CO & over-range protection OVERVIEW Test domestic gas, ...
KANE 358 Flue Gas Analyser with CO sensor protection OVERVIEW KANE358 has a large 6 line display ...
KANE458s IAQ Indoor Air Quality Analyser FGA & IAQ Analyser measuring O2, CO & ambient CO2 OVERVIEW ...
KANE958 Commercial Analyser Flue Gas Analyser with direct CO O2 & CO sensor protection OVERVIEW ...
KANE988 Industrial Flue Gas Analyser With High Suction Pump FEATURES * Tests any boiler up to & over ...
KANE988+ Boiler Engine & A/C Refrigeration Analyser OVERVIEW Test any size boiler with high suction ...