Home Companies Beijing HiYi Technology Co., Ltd

Tylosin Tilmicosin Combo Rapid Test Strip For Milk

Beijing HiYi Technology Co., Ltd

Contact Us

Trade Verify

Address: Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China

Contact name:Lisa Niu

Inquir Now

Beijing HiYi Technology Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Tylosin Tilmicosin Combo Rapid Test Strip For Milk

City & Province beijing beijing
Categories Tape Measures
InquireNow

Product Details

Tylosin-Tilmicosin Combo Rapid Test Strip

 

OVERVIEW

 
Brief:
The Tylosin-Tilmicosin rapid test strip is used for testing Tylosin and Tilmicosin residue in milk(including pure milk and fresh milk) and goat milk qualitatively. The whole test only need 6min, east to operate with high sensitivity.
 

Principle:

The Tylosin-Tilmicosin rapid test strip is based on competitive inhibition immuno-chromatographic principle. In the flow process, Tylosin-Tilmicosin in the sample combined with Tylosin-Tilmicosin specific colloidal gold-labeled monoclonal antibody, Inhibit the combination between antibody and Tylosin-Tilmicosin-BSA conjugate on Test line of NC membrane, lead to the color change of Test line. When the sample has no Tylosin-Tilmicosin residue or concentration lower than detection limit, T line is darker then C line; when the concentration is equal to or higher than detection limit, T line is lighter than C line or T line has no color or T line has same color with C line. No matter whether there is Tylosin-Tilmicosin residue in sample, C line will appear, it means the test is valid.

 
FEATURES & BENEFITS

 
Operation procedures:

1 Read the instruction carefully before use. Return test strips and sample into room temperature.

2 Take bottles needed from the kit package, take out required microwells, making proper marks, Please use it in 1 hour. Seal the cap of the bottles, avoid moisture.

3 Use Micro-pipette to take 200ul of the samples into the microwells, then repeatedly absorb for 5 times, mix the sample with the reagent in the microwells completely until no solid judged by eyes (this is a very important step).

4 Incubate at 40±2℃for 3 min. Then insert the strip into micro-well, put the end with MAX down into the liquid.

5 Insert the strip into the liquid for 3min, then read the result.


Test Result Interpretation:

Color depth comparison of T line and C lineResult judgmentResult analysis
T line >C lineNegativeTylosin-Tilmicosin residue is lower than detection limit in sample
T line =C lineWeak positiveTylosin-Tilmicosin residue is equal to detection limit in sample
T line <C line or T line is invisiblePositiveTylosin-Tilmicosin residue is higher than detection limit in sample
C line is invisibleInvalid

The test strip is invalid, test again

 
Results picture show:

 
Precautions:

1) The test strip is used for once at room temperature, do not use test strip out of date.

2) Cover the bottle immediately after taking out the reagent. If can’t use 8 micro-wells for one time, cover the micro-wells immediately and put back to the bottle, store in seal.

3) Do not touch the white membrane surface in the middle of test strip, avoid sunlight and fan blowing directly.

4) Milk samples should be fully liquid without any agglomeration, sour and precipitation

5) Use the test strips testing again for positive results.

6) Please contact the supplier for any questions.

7) The result is for reference. To confirm, please refer national standard method.


Specificity:
This product has no cross-reaction with Quinolones, Sulfonamides and Tetracyclines etc.

 
SPECIFICATIONS

 
Storage and expiry date:
Storage: Store at 2-8 ℃ in sealed, dry, and dark place,no frozen.
Expiry date: 12 months; date of production is on box.

 
Detection limit in milk :

NameDetection limit ppb(ug/kg)
Tylosin2-3
Tilmicosin3-5

 


 

Hot Products

KANE458s Flue Gas Analyser with direct CO2, CO & over-range protection OVERVIEW Test domestic gas, ...
KANE 358 Flue Gas Analyser with CO sensor protection OVERVIEW KANE358 has a large 6 line display ...
KANE458s IAQ Indoor Air Quality Analyser FGA & IAQ Analyser measuring O2, CO & ambient CO2 OVERVIEW ...
KANE958 Commercial Analyser Flue Gas Analyser with direct CO O2 & CO sensor protection OVERVIEW ...
KANE988 Industrial Flue Gas Analyser With High Suction Pump FEATURES * Tests any boiler up to & over ...
KANE988+ Boiler Engine & A/C Refrigeration Analyser OVERVIEW Test any size boiler with high suction ...