Industrial NH3 Sensor Ammonia Fixed Gas Detector Real Time Monitoring

City & Province beijing beijing
InquireNow

Product Details

HiYi Data Acquisition Module ATEX IECEx Real-Time Monitoring Industrial NH3 Sensor Ammonia Fixed Gas Detect
 
MIC300 Fixed Gas Monitoring System
Single Gas | Remote Control | Alarm
 
OVERVIEW


MIC300 Series gas detector can be used in 24 hours continuous online monitoring of concentrations of multiple types of gases in the filed.The types for detection are more than 500 types.
With a 4-20 mA analogue output, can be simply integrated into a Distributed Control System (DCS) to provide warnings and enable control of high levels in the working environment.
Simple to install service and calibrate, MIC500 requires no hot work permit and the PID sensor is accessible and changeable in a matter of seconds.
Strong, durable and explosion-proof shell and fluorocarbon surface treatment process are suitable for the use at a variety of hazardous places and corrosive environments, it is wear-resistant.
Simple calibration procedure.
Easily integrated into a control system.

 

FEATURES & BENEFITS

 

◼︎ Fast and efficient gas detection function

  • It can be used in 24 hours continuous online monitoring of single field gas concentration and the types for detection are more than 500 types.

◼︎ Diversified communication methods

  • It is possible for the real-time monitoring via the wired or remote wireless transmission, and network transmission.
  • Three-wire system 4 ~ 20mA standard signal and standard bus RS485 (modbus-RTU) simultaneous output.
  • It is compatible with secondary instrument, data acquisition module, PLC, DCS system, and it is possible to drive the related equipment.

◼︎ Powerful and convenient humanized function

  • Data recovery function; in case of mis-operation, it is possible to select partial or full recovery.
  • Multiple alarm modes, and multi-directional and three-dimensional indication alarm states, includes: 2 sets of relay switch output, sound & light alarm (optional configuration).Alarm types include: concentration alarm, and failure alarm.
  • Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may be caused by human factors.
  • Zero-point automatic tracking; long-term use will not be affected by the zero drift.
  • Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements.
  • Broad operating temperatures: -40~+70℃, and temperature compensation is supported.
  • Intrinsically safe circuit design, explosion-proof, with Level II lightning protection, and anti-static capabilities. Meet the national standard, and it is resistant to the high-intensity pulse surge current. With the function of preventing the reverse connection. It is compliant with EMI, and EMC standards.

◼︎ ◼︎ ◼︎ ◼︎ Optional Items ◼︎ ◼︎ ◼︎ ◼︎
◼︎ Wireless transmission

  • It is possible to transfer data wirelessly to the cell phone, remote monitoring center, monitoring computers and other monitoring equipment, which will utilize the upper-level host to realize the functions of data analysis, storage, printing or the like on the computer.

◼︎ Pretreatment system

  • Room temperature and high humidity pretreatment system
  • High temperature and high humidity pretreatment system
  • High dust pretreatment system

◼︎ Accessory for connection with computer for monitoring

  • Free upper-level host software, RS485 / RS232 converter
  • For laptop without RS232 interface, USB / RS232 converting and connecting cable is needed, if the network transmission is needed, TCP / IP converter will be further needed.

 

INSTALLATION INSTRUCTIONS


①wall mounting bracket
②mounting clips for fixation on the pipes (1/2", 3/4" pipe)
③stainless steel threaded welding seat or flange to be installed on the pipeline (it is necessary to mark the flange or pipe size, such as DN50, DN15 ...)
④Rain cover
⑤24VDC or 220AC sampling pump (sampling distance is 10 m)
⑥vacuum pump (sampling distance is greater than 40 m)
⑦24V switching power supply
⑧pressure reducing valve
⑨flow meters

 

SPECIFICATION

 

Gas
Toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.
Detection range
0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 100%LEL, 20%, 50%, 100%Vol can be selected; and other ranges can be customized.
Resolution
0.01ppm (0 ~ 100 ppm), 0.1ppm (0 ~ 1000 ppm), 1ppm (0 ~ 1000 ppm or more), 0.1% LEL, 0.01%Vol
Detection principle
Electrochemical, infrared, thermal conductivity, PID photoionization, and so on.
Depending on the type of gas, range, field environment and user demand,
Sensor can be customized
Sensor service life
Electrochemical principle: 2 ~ 3 years;
Infrared principle: 5 ~ 10 years;
Thermal conductivity: 5 years
Allowable error
≤±3% F.S (other or higher precision levels can be customized)
Linearity
≤±2%
Repeatability
≤±2%
Uncertainty
≤±2%
Response time
T90≤30 seconds
Recovery time
≤30 seconds
Working environment
Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH (regular)
Working voltage
12 ~ 30VDC direct current
the standard power supply for a single equipment is 24V, DC stabilized voltage switching power supply of 1A or greater than 1A
Power supply reference
24V, 2.1A is possible to drive 40 units of toxic gas detector,
or 15 units of flammable, infrared gas detector.
Working method
Fixed type installation, online detection, diffusion type measurement
Protection level
IP65
Explosion-proof mark
ExdⅡCT6, certificate number: CNEx15.1283
Exterior dimensions
233×205×65mm (L×H×W)
Weight
1.0 Kg
Standard accessories
Manual, qualification certificate, warranty card, outer packaging box

 

 

APPLICATION

 

All the cases which requires the fixed installation, and online detection of gas concentrations such as Chemical Industry, Power Generation Plants, Natural Gas Pipeline & Processing,Pulp & Paper Industry, Waste Water Treatment Plants, Commercial & Industrial HVAC, Acetylene Gas Bottlers & Users , Ice Skating & Hockey Arenas,Cannabis & Hemp Oil, Breweries and so on.

Hot Products

KANE458s Flue Gas Analyser with direct CO2, CO & over-range protection OVERVIEW Test domestic gas, ...
KANE 358 Flue Gas Analyser with CO sensor protection OVERVIEW KANE358 has a large 6 line display ...
KANE458s IAQ Indoor Air Quality Analyser FGA & IAQ Analyser measuring O2, CO & ambient CO2 OVERVIEW ...
KANE958 Commercial Analyser Flue Gas Analyser with direct CO O2 & CO sensor protection OVERVIEW ...
KANE988 Industrial Flue Gas Analyser With High Suction Pump FEATURES * Tests any boiler up to & over ...
KANE988+ Boiler Engine & A/C Refrigeration Analyser OVERVIEW Test any size boiler with high suction ...