5kv - 20kV Portable AC Hipot Tester For HV High Voltage Withstand Test

Country/Region china
City & Province wuhan hubei
InquireNow

Product Details

                                 ZX267X Series Portable High Voltage Dielectric Withstand Tester

 

Product introduction:

 

   This series of high voltage  dielectric withstand tester is a basic type voltage withstanding tester with excellent performance.

   The output voltage is regulated by regulator of high reliability and high durability. LED digital high brightness screen displaying test time, voltage, current, real-time displaying breakdown current value and voltage value; alarm current value freely preset; test time display in three digital tube, the minimum resolution time 0.1s, time preset range 0.0s to 999s. Equipped with the signal input and output interface for PLC, it can be easily integrated with PLC for a test system, quickly and accurately measure the dielectric strength of electronic components, household appliances, insulation materials, instruments and meters, lighting appliances and electric heating appliances.

 

Product Characteristics:

 

1. The display mode is digital display.
2. It can display the leakage current value of the measured object during the test.
3. With time preset and display, test time countdown.
4. The alarm current value can be set arbitrarily.
5. The output waveform is a 50Hz sine wave.

 

 

This s      Standards:

 

     This series of products meet the following standards:

Household appliances standards(IEC60335, GB4706-1-2001, GB4706-1-1998)

lighting standards(IEC60598-1-1999, GB7000-1-2000)

Information standards(GB8898-2001, GB12113, GB4943-2001, IEC60065, IEC60950)

Medical standards ( IEC601-1-1998, GB4706.1-1998, GB4793.1-2007 ) etc.

 

 

Model series  :

 

 ACDC
5KV10KV20KV5KV10KV20KV
ZX2670A20mA----------
ZX2671A--20mA----10mA--
ZX2671B--50mA----20mA--
ZX2671C--100mA----20mA--
ZX2672A20mA----10mA----
ZX2672B100mA----------
ZX2672C100mA----20mA----
ZX2672D200mA----20mA----
ZX2674A----20mA----10mA

 

 

Technical Parameter:

 

1) Technical parameter of ZX2670A,ZX2672A,ZX2672B,ZX2672C,ZX2672D

 

ItemsModelZX2670AZX2672AZX2672BZX2672CZX2672D
ACWOutput voltage range(0.00~5.00)kV
Maximum output power

100VA

(5.000kV/20mA)

500VA

(5.0kV/100mA)

1000VA

(5.0kV/200mA)

Maximum rated current20mA100mA200mA
Current stalls2mA,20mA2mA,20mA,100mA2mA,20mA,200mA
Output waveformSine wave
Output waveform distortion≤5%(No-load or pure resistive load)
Test time0.0s~999s 0.0=continuous test
DCWOutput voltage range————(0.00~5)kV————(0.00~5.00)kV
Maximum output power————50VA(5kV/10mA)————100VA(5.00kV/20mA)
Maximum rated current————10mA————20mA
Current taps————2mA,10mA————2mA,20mA
Ripple factor————≤5%————≤5%
Test time————

0.0s~999s

0.0=

Continuous test

————0.0s~999s 0.0=continuous test
VRange(0.00~5.00KV)
accuracy±(5%+3 words)
Resolution10V
Display the valueRoot mean square value
Ameasuring rangeAC0.100mA~20.0mA0.100mA~100mA0.1mA~200mA
DC————0.1mA~10.0mA————0.100mA~20.0mA
Resolution2mAfile:1uA,20mA file:10uA,100mA(200mA) file:0.1mA
measurement accuracy±(5%+3 words)
Timerrange0.0s~999s
Minimum resolution0.1s
Accuracy±(1% + 50ms)
Interface of PLCOptional
Remote control interfaceYes
Exterior dimension315*285*175mm440*380*180430*375*190
Weight8.76Kg9.10Kg13.72Kg18.2Kg24.6Kg

 

2)  Technical parameter of ZX2671A,ZX2671B,ZX2671C

 

ItemsModelZX2671AZX2671BZX2671C
ACWOutput voltage range(0.00 ~10.00)kV
Maximum output power200VA(10.0kV/20mA)500VA(10.0kV/50mA)1000VA(10.0kV/100mA)
Maximum rated current20mA50mA100mA
Current taps2mA,20mA2mA,20mA,50mA2mA,20mA,100mA
Output waveformSine wave
Output waveform distortion≤5%(No-load or pure resistive load)
Test time0.0s~999s 0.0=continuous test
DCWOutput voltage range(0.00~10.0)kV
Maximum output power100VA(10.0KV/10mA)200VA(10.0KV/20mA)
Maximum rated current10mA20mA
Current taps2mA,10mA2mA,20mA
Ripple factor≤5 %
Test time0.0s~999s 0.0=continuous test
VRange(0.00~10.0KV)
accuracy±(5%+3 words)
Resolution10V
Display the valueRoot mean square value
Ameasuring rangeAC0.100mA~20.0mA0.100mA~50mA0.100mA~100mA
DC0.100mA ~10.0mA0.100mA ~20.0mA
Resolution2mA stop:1uA, 20mA stop:10uA,50mA(100mA) stop:0.1mA
measurement accuracy±(5%+3 words)
Time meterrange0.0s~999s
Minimum resolution0.1s
Accuracy±(1% + 50ms)
PLC interfaceOptional
Remote control interface Yes
Exterior dimension380*305*195mm443*390*220mm440*380*180mm
Weight14.76Kg25Kg18.2Kg

 

 

 

 

 

 

 

 

PLEASE NOTE :

 

Wuhan GDZX Power Equipment Co.,Ltd OFFER YOU :

1: FACTORY DIRECT PRICE.
2: NICE QUALITY.
3: QUICK SHIPPING WITHIN 15 DAYS.

4: SMALL ORDER WELCOME..

5: ONLINE PAYMENT.

6: SUPPORT One year free warranty, three years quality assurance, lifetime maintenance.

7: AFTER SALES SERVICES 24/7  

 

Hot Products

Inductance Adjustable AC Voltage Withstand Resonant Test System for Generators High Voltage Test ...
ZXBXZ Series Resonant Test System for Substation Product introduction This ZXBXZ Series Devices are ...
ZXBXZ Series Resonant Test System for Substation Product introduction This ZXBXZ Series Devices are ...
Resonant test system for CVT This resonant tester is widely used for Capacitive Voltage Transformer ...
High Voltage Resonant Test System Inductance Adjustable AC High Voltage Resonant Test System For ...
ZXBXZ Series Resonant Test System for Substation Product introduction This ZXBXZ Series Devices are ...