Item | Specifications | Min. | Typ. | Max. | Unit | Notes |
2.01 | Signal wavelength | 1000 | 1060 | 1100 | nm |
|
2.02 | Pump wavelength | 800 | 915 | 1000 | nm |
|
2.03 | Polarization | Random | PM Customizable | |||
2.04 | Operation regime | CW |
| |||
2.05 | Fiber length |
| 1.5 |
| m | Default |
2.06 | Operating temperature range | 0 |
| +70 | °C |
|
2.07 | Storage temperature | -40 |
| +85 | °C |
|
2.08 | Cooling Method | Bottom conduction cooling |
|
3.0 Typical fiber combinations
Item | Confi. | Pump Fiber | Signal Fiber | Output Fiber | Power Handling | Pump Efficiency | Signal Power | Signal IL | Note |
3.01 | (6+1)×1 | 105/125 106.5/125 135/155 | X/250DCF | Y/130DCF Y/250DCF | 300W/leg | 97% | 2kW | 0.2dB | X,Y=14, 20, 25, 30 X≤Y |
3.02 | X/400DCF | Y/250DCF Y/400DCF | 300W/leg | 97% | 2kW | 0.2dB | X,Y=20, 25, 30 X≤Y | ||
3.03 | 200/220 220/242 225/240 | 20/400DCF | Y/250DCF Y/400DCF | 600W/leg | 97% | 3kW | 0.2dB | Y=20, 25, 30 | |
3.04 | 25/400DCF | Y/250DCF Y/400DCF | 600W/leg | 97% | 3kW | 0.2dB | Y=25, 30 | ||
3.05 | 30/400DCF | Y/250DCF Y/400DCF | 600W/leg | 97% | 3kW | 0.2dB | Y=30 | ||
3.06 | (18+1)×1 | 105/125 106.5/125 | X/250 DCF | Y/130 DCF | 150W/leg | 96% | 3kW | 0.2dB | X,Y=20, 25, 30 X≤Y |
3.07 | X/400 DCF | Y/130 DCF Y/250 DCF | 150W/leg | 96% | 3kW | 0.2dB | X,Y=20, 25, 30 X≤Y | ||
3.08 | 135/155 | X/400 DCF | Y/130 DCF Y/250 DCF | 150W/leg | 96% | 3kW | 0.2dB | X,Y=20, 25, 30 X≤Y |
4.0 Mechanical specifications and drawings
Item | Specifications | Unit | Notes | |
4.01 | Module’s Dimensions | 150*15*12 | mm | Bottom conduction cooling |
5.0 Ordering information
HSP-1-2-3-4-5-6/7-8/8-9 | ||
1:Port combination | 2:Signal propagation direction | 3:Pump fiber type |
61 - (6+1) 1 181 - (18+1) 1 | F - Forward B – Backward
| M01 - 105/125, 0.22NA M03 - 135/155, 0.22NA ect. |
4:Signal input fiber type | 5:Signal output fiber type | 6:Pump power per port |
D17 - 20/400 DCF, 0.06NA D07 - 25/400 DCF, 0.06NA D08 - 30/400 DCF, 0.06NA ect. | D03 – 20/250 DCF, 0.06NA D04 – 25/250 DCF, 0.06NA D05 – 30/250 DCF, 0.06NA ect. | 200 - 200W 400 - 400W 600 - 600W ect. |
7:Handling signal power | 8/8:Input/Output fiber length | 9:Package type |
1.0 - 1000W 1.5 - 1500W 2.0 - 2000W 3.0 - 3000W 5.0 - 5000W ect. | 1.0-1.0m 1.5-1.5m Default 2.0-2.0m ect. | A - Aluminum package 150*15*12 S - Specify |
For example:HSP-61-B-M03-D17-D03-400/2.0-1.5/1.5-A |