Low Temperature 0.6mm Hook Coblation Wands 30° Probe 90° Tip

Country/Region china
City & Province chengdu sichuan
Categories Other Hand Tools
InquireNow

Product Details

Low Temperature Hook Coblation Wand for Sports Medicine Surgeries

 

 

Product Advanatages

 

Hook coblation wands can be performed on different joints in the body, including the knee, shoulder, hip, wrist, ankle, and elbow. These procedures involve the removal, repair, or reshaping of various components of the joint, such as the meniscus, soft tissue, ligaments, synovial membrane, and tendons.

Some specific examples of these procedures include complete or partial removal of the meniscus, repairing and reshaping the meniscus, tightening or releasing ligaments, removing pathological synovial tissue, clearing out intra-articular debris, treating osteoarthritis associated with aging, restoring wounds, and treating bone infections.

It is important to note that these procedures should only be performed by qualified medical professionals and should be considered on a case-by-case basis based on the patient's individual needs and medical history.

 

Specification

 

Model

DQG-E3020-A120

Length

130mm

Diameter

0.6mm

Angle

30° probe, 90° tip

Working Degree

40-70 degree

 

Applications

 

Cutting meniscus, lateral retinacular slack for knee and shoulder

 

Precautions for the use of plasma coblation wand in combination with plasma console:

 

(a) Check the expiration date and package integrity of the disposable coblation wand before use.

 

(b) The patient should not come into contact with the metal components of grounded equipment, and the use of antistatic plates is recommended.

 

(c) The disposable coblation wand cable should be kept away from patients and other leads, and temporarily unused probes should be stored away from patients.

 

(d) If the output is significantly reduced or the equipment fails to function normally, it may indicate poor probe contact or improper use.

 

(e) Flammable cleaning agents and solvents should be evaporated before using the plasma surgical system equipment, and flammable fluids should be wiped off from the patient's body and cavity.

 

(f) High-frequency current may interfere with cardiac pacemakers, so the current loop should not pass through the active implantable device.

 

(g) When installing the disposable coblation wand and powering on the equipment, avoid contact between the electrode and metal enclosure, and keep physiological monitoring equipment away from the probe as much as possible.

 

More Photos

 

Hot Products

Product Description: The IOS Platform Wireless Ultrasound Probe with Internal Wifi Connectivity has ...
AI Digital Renal Care Handheld Ultrasound Scanner For Android And IOS Devices Product Description: ...
High-Performance Electronic Linear Array PICC Handheld Ultrasound Scanner Product Description: The ...
Advanced Handheld Ultrasound Scanner 0.2kg With 3000mAh Battery For Medical Professionals Product ...
Electronic Linear Array Handheld Ultrasound Scanner With 2 Hours Working Time Product Description: ...
Product Description: The Lite series wireless handheld Doppler ultrasound machine utilizes cutting...