Portable Compact Gasoline Generator Forced Air Cooling 110/220V

 

common fault:

 

The no-load voltage is too high:


(1) Automatic voltage regulator is out of control. The excitation winding current of no-load exciter is too large. Check the automatic voltage regulator.


(2) The setting voltage is too high to reset the voltage.


Excitation current of exciter:


(1) The rectifier element has one or two components in the positive and negative circuit, check with a multimeter, replace the damaged components.


(2) The main generator or exciter part of the excitation winding short circuit, measure the DC resistance value of each pole coil. Replace the coil with a short circuit fault.


Steady-state voltage adjustment rate:


Automatic voltage regulator has a fault check and troubleshoot.


High vibration:


(1) Poor docking with prime mover check and correct docking. After the bolts are fastened, ensure that the generator and the prime mover axis are straight and concentric.


(2) The rotor dynamic balance is not good, occurs after the rotor is rewound, should find the positive dynamic balance.


(3) Short-circuit of the excitation winding of the main generator measure the DC resistance of each pole and find out the short-circuit fault point. Replace the coil.


(4) Bearing damage, generally bearing cover overheating phenomenon, replace the bearing.


(5) If the prime mover is faulty, check the prime mover.


overheating:


(1) The generator is overloaded, so that the load current and voltage do not exceed the rated value.


(2) The load power factor is too low, adjust the load, so that the excitation current does not exceed the rated value.


(3) If the speed is too low, adjust the speed to the rated value.


(4) There is a short circuit in some windings of the generator. Find out the short circuit and correct or replace the coil.


(5) The air duct is blocked, the obstacles are removed, the motor is dismantled, and the air duct is thoroughly blown.

 

Product Description:

 

DIGITAL INVERTER GENERATOR 3.3HP/2KW
Model Number8896219
Number of phases1 ph
Maximum power2kw
Rated power1.85kw
Voltage/frequency230v/50hz
Power factor1
Engine
Max.engine power2.5kw(3.3hp/5500/min)
Displacement80cc
Startingrecoil
Consumptionapprox. 0.9 1/kwh
Tank volume4.5 l
Generator
Type of generatormultipole,digital control,inverter.
AC rated current8.0A/230V
DC rated current8.3A/12V
Weight21.6kg
Dimension42x52x29cm

 

 

 

Hot Products

350/500 Kw Kva Generator Quiet Diesel Generator Brushless Alternator Direction of Development: The ...
50/100/500KW Convenient Silent Diesel Generator Set 120V/400V Coordinated control of battery energy ...
Automatic Start Generator Set 3 Phase Silent Diesel Generator 120V/400V Basic structure: The basic ...
Diesel Generator Super Silent Soundproof And Rainproof Genset 120V/400V The crankshaft of the diesel ...
100kw Super Silent Soundproof And Rainproof Genset 110/220V,220/380V,230/400V parameter: Manufacture...
Energy Silent Power Magnetic Generator Price 3 - Phase Diesel Generator Set Features: * Control with ...