Home Companies Guangdong ALI Testing Equipment Co,.Ltd

1306-E87TA330 Perkins Diesel Generator , 4 Stroke , 220 KW

Guangdong ALI Testing Equipment Co,.Ltd
Active Member

Contact Us

[China] country

Address: No. 2, Shajiao Sijia Gate, Humen Town, Dongguan City, Guangdong Province, China

Contact name:Kris

Inquir Now

Guangdong ALI Testing Equipment Co,.Ltd

1306-E87TA330 Perkins Diesel Generator , 4 Stroke , 220 KW

Country/Region china
City & Province dongguan guangdong
Categories Diesel Generators
InquireNow

Product Details

 

1. Standby power:                             220.0 KW

2. Engine Make & Model:      Perkins 1306-E87TA330

3.Alternator Model:                            LL5014J

4.Base Frame Type:           Heavy Duty FabriCAT-parts-partsed Steel

5.Circuit Breaker Type:                   3 Pole MCCB

6.Cooling Method:                         Water Governing 

7.Type:                                      Electronic Governing 

8.Class:                                           ISO 8528 G2

9.Compression Ratio:                          16.9:1

10.Displacement: l (cu.in)                 8.7 (530.9) 

 

4 Stroke LL5014J Perkins Diesel Generator , 1306-E87TA330

 

Output Ratings

Generating Set Model

P250H                      P275HE   Prime*                     Standby*

380-415V, 50 Hz

 250.0 kVA                275.0 kVA

  200.0 kW                 220.0 kW

220/127V, 60 Hz

-                               -

-                               -

  • Refer to ratings definitions on page 4.

           Ratings at 0.8 power factor.

 

Technical Data

Engine Make & Model:

Perkins 1306-E87TA330

Alternator Model:

LL5014J

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole MCCB

Frequency:

50 Hz           60 Hz

Engine Speed: RPM

1500                   -

Fuel Tank Capacity: litres (US gal)

350 (92.5)

Fuel Consumption:  P250H    l/hr (US gal/hr)

53.1 (14.0)               -

Fuel Consumption:   P275HE   l/hr (US gal/hr)

56.3 (14.9)               -

P250H / P275HE

 

Engine Technical Data

 

Physical Data  

 

Manufacturer:                                                                        Perkins

Model:                                                                            1306-E87TA330

No. of Cylinders/Alignment:                                                 6 / In Line

Cycle:                                                                                  4 Stroke

Induction:                                                                         Turbocharged

Air To Air Charge Cooled Cooling Method:                   Water Governing

Type:                                                                          Electronic Governing

Class:                                                                               ISO 8528 G2

Compression Ratio:                                                             16.9:1

Displacement: l (cu.in)                                                     8.7 (530.9)

Bore/Stroke: mm (in)                                              116.6 (4.6)/135.9 (5.4)

Moment of Inertia: kg m² (lb. in²)                                      1.54 (5266)

Engine Electrical System:

-Voltage/Ground:                                                            24/Negative

-Battery Charger Amps:                                                         45

Weight: kg (lb) - Dry:                                                       671 (1479)

- Wet:                                                                              698 (1539)

 

Air System 

 

Air Filter Type:                                                              Replaceable

Element Combustion Air Flow: m³/min (cfm)       

-Standby:                                                                       16.4 (579)              

-Prime:                                                                           16.4 (579)              

- Max. Combustion Air Intake Restriction: kPa (in H2O) 6.2 (24.9)               

- Radiator Cooling Air Flow: m³/min (cfm)                  318.0 (11230)           

- External Restriction to Cooling Air Flow: Pa (in H2O)    125 (0.5)               

 

Performance                                50 Hz                                                        60 Hz

 

Engine Speed: RPM                      1500                      

- Gross Engine Power: kW (hp)

-Standby:                                  246.0 (330.0)               

-Prime:                                      224.0 (300.0)               

- BMEP: kPa (psi)

-Standby:                                2260.0 (327.8)             

-Prime:                                    2058.0 (298.5)      

- Regenerative Power: kW  20.8        

 

Cooling System                            50 Hz                                                       60 Hz

 

Cooling System Capacity:l (US gal)                             39.8 (10.5)              

- Water Pump Type:                                                    Centrifugal

Heat Rejected to Water &Lube Oil: kW (Btu/min)

-Standby:                                 107.5 (6113)            

-Prime:                                      99.5 (5658)             

- Heat Radiation to Room:

kW (Btu/min)        

-Standby:                                 45.0 (2559)              

-Prime:                                     39.0 (2218)              

- Radiator Fan Load: kW (hp)  7.0 (9.4)               

Cooling system designed to operate in ambient conditions up to 50°C (122°F).

 

LubriCAT-parts-partsion System

 

Oil Filter Type:                                Spin-On, Full Flow

Total Oil Capacity l (US gal):                26.4 (7.0)

Oil Pan l (US gal):                                22.7 (6.0)

Oil Type:                                        API CG4 15W-40

Cooling Method:                                     Water

 

Fuel System

 

Fuel Filter Type:                  Replaceable Element Recommended

Fuel:                                             Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

 

110%              100%               75%                50%

Load               Load               Load               Load

P250H

 

50 Hz         56.3 (14.9)      53.1 (14.0)      42.5 (11.2)       29.0 (7.7)

60 Hz                 -                      -                       -                      -

 

P275HE

 

50 Hz                                56.3 (14.9)      46.0 (12.2)       31.9 (8.4)

60 Hz                                        -                       -                      -

 

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

 

Exhaust System                           50 Hz                                                       60 Hz

 

Silencer Type:                                                               Level 1

Silencer Model & Qty:                                SD100 (1) Pressure Drop Across

Silencer System: kPa (in Hg)                                    8.70 (2.569)             

- Silencer Noise Reduction Level: dB                               12                     

- Max. Allowable Back Pressure: kPa (in. Hg)             10.7 (3.2)               

- Exhaust Gas Flow: m³/min (cfm)       

-Standby:                                    44.5 (1572)              

-Prime:                                        44.5 (1572)              

- Exhaust Gas Temperature:  °C (°F)

m³/min (cfm)       

-Standby:                                      528 (982)               

-Prime:                                          500 (932)         

P250H / P275HE

 

Alternator Performance D

Data Item

                  50Hz    

415/240V

400/230V

230/115V

200/115V

380/220V

220/110V

220/127V

Motor Starting Capability* kVA

623

585

536

686

Short Circuit Capacity** %

300

300

300

300

Reactances: Per Unit

Xd X'd X''d

2.450

0.110

0.067

2.630

0.120

0.072

2.920

0.130

0.080

2.130

0.100

0.058

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.

 

Alternator Technical Data

 

Physical Data                                                                   Operating Data

Manufacturer:   FG WILSON

Overspeed: RPM     2250

Model:        LL5014J

Voltage Regulation (steady state) (%):    + /- 0.5

No. of Bearings:    1

Wave Form NEMA = TIF:  50

Insulation Class:  H

Wave Form IEC = THF:  2.0%

Winding Pitch Code: 2/3 - 6

Total Harmonic Content LL/LN:  4.0%

Wires:    12

Supression is in line with European Standard

Radio Interference:       EN61000-6

Ingress Protection Rating:  IP23

Radiant Heat: kW (Btu/min)

-50 Hz:  18.1 (1029)

-60 Hz:   -

Excitation System:     SHUNT

AVR Model:      R448

P250H / P275HE

 

Technical Data

 

3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz,- RPM

 

 

Voltage   Prime Model      Standby Model          Voltage          Prime Model        Standby Model

                P250H                         P275HE                                            -                                  -

 

kVA                 kW

kVA                 kW

 

kVA                 kW

kVA                  kW

415/240V

250.0              200.0

275.0              220.0

 

 

 

400/230V

250.0              200.0

275.0              220.0

 

 

 

380/220V

250.0              200.0

275.0              220.0

 

 

 

230/115V

250.0              200.0

275.0              220.0

 

 

 

220/127V

245.0              196.0

275.0              220.0

 

 

 

220/110V

250.0              200.0

275.0              220.0

 

 

 

200/115V

250.0              200.0

275.0              220.0

 

 

 

 

 

 

230/115V

-                      -

-                      -

 

Definitions

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

 

Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

 

Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

 


 

Weights and Dimensions

Weights: kg (lb)                                                             Dimensions: mm (in)

 

 

Net (+ lube oil)

 

2215 (4883)

 

Length

 

2960 (116.5)

Wet (+ lube oil & coolant)

2252 (4965)

Width

1003 (39.5)

Fuel, lube oil & coolant

2547 (5615)

Height

1718 (67.6)

 

General Data

 

Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.


 

Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.

 

Warranty

All equipment carries full manufacturer's warranty.

 

Hot Products

Alternator Brand:Original Stamford Alternator Model:UCI274C Prime Power:80KW / 100KVA Frequency:50HZ ...
150kva Volvo Generator Diesel( JP-V120) Volvo Engine: TAD731GE Prime Power: 150KVA/120KW 150kva ...
Standby power:200 kW Prime power:182 kW Rated speed:1800 RPM Phase:3 Rated voltage:480 V 6 Cylinder ...
Model:TAD940GE Cylinder Arrangement:6 in line Air Intake System:Turbo Rated Power:240KW 240KW Single ...
Genset Model:JP-V250 Genset Output Power:250KW Rated Voltage:380/220V Frequency:50hz 4 stroke Volvo ...
​ 400KW IP21 Volvo Diesel Generator , Turbo Charged Generator Brand:VOLVO Genset Model:JP-V400 ...