Product Details

 

1. Standby power:                                    400.0 KW

2.Engine Make & Model:              Perkins 2506A-E15TAG1

3.Alternator Model:                                  LL6114D

4.Cooling Method:                             Water Governing

5.Type:                                           Electronic Governing

6.Class:                                                  ISO 8528 G2

7.Compression Ratio:                                 16.0:1

8.Displacement: l (cu.in)                         15.2 (927.6)

9.Bore/Stroke: mm (in)                    135.0 (5.3)/167.0 (6.6)

10.Moment of Inertia: kg m² (lb. in²)      4.29 (14660) 

 

3 Phase Ratings Perkins Diesel Generator , 1500 RPM

 

Output Ratings

Generating Set Model

*                               P500E3

Prime*                     Standby*

380-415V,50Hz

450.0 kVA                500.0 kVA

360.0 kW                 400.0 kW

220/127V, 60 Hz

-                               -

-                               -

  • Refer to ratings definitions on page 4.

             Ratings at 0.8 power factor.

 

Technical Data

Engine Make & Model:

Perkins 2506A-E15TAG1

Alternator Model:

LL6114D

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole MCCB

Frequency:

50 Hz           60 Hz

Engine Speed: RPM

1500                   -

Fuel Tank Capacity: litres (US gal)

928 (245.2)

Fuel Consumption:   P450P3   l/hr (US gal/hr)

88.8 (23.5)               -

Fuel Consumption:   P500E3    l/hr (US gal/hr)

98.6 (26.0)               -

P450P3 / P500E3

 

Engine Technical Data

 

Physical Data 

 

Manufacturer:                                                         Perkins

Model:                                                            2506A-E15TAG1

No. of Cylinders/Alignment:                             6 / In Line

Cycle:                                                                     4 Stroke

Induction:                                      Turbocharged Air To Air Charge Cooled

Cooling Method:                                                    Water

Governing Type:                                                Electronic

Governing Class:                                            ISO 8528 G2

Compression Ratio:                                           16.0:1

Displacement: l (cu.in)                                  15.2 (927.6)

Bore/Stroke: mm (in)                               135.0 (5.3)/167.0 (6.6)

Moment of Inertia: kg m² (lb. in²)                  4.29 (14660)

Engine Electrical System:

-Voltage/Ground:                                             24/Negative

-Battery Charger Amps:                                        70

Weight: kg (lb) - Dry:                                      1633 (3600)

- Wet:                                                                 1714 (3779)

 

Air System                                                     50 Hz                                                                           60 Hz

 

Air Filter Type:                                                                                       Paper

Element 18" Combustion Air Flow:m³/min (cfm)       

-Standby:                                                       30.5 (1077)                                                                      -

-Prime:                                                           25.8 (911)              

- Max. Combustion Air Intake Restriction: kPa (in H2O)             6.2 (24.9)               

- Radiator Cooling Air Flow:m³/min (cfm)                                 660.0 (23308)           

- External Restriction to Cooling Air Flow: Pa (in H2O)             125 (0.5)     

 

Cooling System                                            50 Hz                                                                            60 Hz

Cooling System Capacity:

l (US gal)                                                   38.3 (10.1)              

- Water Pump Type:                                                                       Centrifugal

Heat Rejected to Water &

Lube Oil: kW (Btu/min)

-Standby:                                                 157.0 (8928)                                                                          -

-Prime:                                                     137.0 (7791)            

- Heat Radiation to Room:

kW (Btu/min)        

-Standby:                                                  47.0 (2673)          

-Prime:                                                      28.0 (1592)              

- Radiator Fan Load: kW (hp)                16.0 (21.5)                                                                             -

Cooling system designed to operate in ambient conditions up to 50°C (122°F).

 

Performance                                                50 Hz                                                                             60 Hz

 

Engine Speed:                                         RPM  1500                      

- Gross Engine Power: kW (hp)

-Standby:                                                443.0 (594.0)               

-Prime:                                                    403.0 (540.0)               

- BMEP: kPa (psi)

-Standby:                                              2471.0 (358.4)               

-Prime:                                                  2248.0 (326.0)               

- Regenerative Power: kW  45.0                       

 

LubriCAT-parts-partsion System

 

Oil Filter Type:                                            Eco, Full Flow

Total Oil Capacity l (US gal):                    62.0 (16.4)

Oil Pan l (US gal):                                      53.0 (14.0)

Oil Type:                                                    API CI4 15W-40

Cooling Method:                                          Water

 

Fuel System

 

Fuel Filter Type:                      Replaceable Element Recommended

Fuel:                                                        Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

 

110%              100%               75%                50% Load               Load               Load               Load

P450P3

 

50 Hz         98.6 (26.0)      88.8 (23.5)      67.3 (17.8)      46.4 (12.3)

60 Hz                 -                      -                       -                      -

 

P500E3

50 Hz                                98.6 (26.0)      74.4 (19.7)      50.9 (13.4)

60 Hz                                        -                       -                      -

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

 

Exhaust System                                           50 Hz                                                                          60 Hz

 

Silencer Type:                                                                                     Level 1

Silencer Model & Qty:                                                   SD150 (1) Pressure Drop Across

Silencer System: kPa (in Hg)                                                     0.34 (0.100)            

- Silencer Noise Reduction

Level: dB                                                                                                15                     

- Max. Allowable Back

Pressure: kPa (in. Hg)                                                                    6.8 (2.0)                

- Exhaust Gas Flow:

m³/min (cfm)      

-Standby:                                                                                       81.0 (2860)              

-Prime:                                                                                           71.4 (2521)              

- Exhaust Gas Temperature:  °C (°F)

m³/min (cfm)       

-Standby:                                                                                        514 (957)               

-Prime:                                                                                            506 (943)                -

 

P450P3 / P500E3

 

Alternator Performance Data

 

Data Item

                                 50 Hz                                                    

415/240V

400/230V

230/115V

200/115V

380/220V

220/110V

220/127V

Motor Starting Capability* kVA

987

923

840

1097

Short Circuit Capacity** %

300

300

300

300

Reactances: Per Unit

Xd X'd X''d

3.280

 

0.180

 

0.124

3.530

 

0.190

 

0.133

3.910

 

0.210

 

0.147

2.790

 

0.150

 

0.105

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.

 

Alternator Technical Data

 

Physical Data                                                                   Operating Data

Manufacturer:      FG WILSON

Overspeed: RPM   2250

Model: LL6114D

Voltage Regulation (steady state) (%):  + /- 0.5

No. of Bearings:  1

Wave Form NEMA = TIF:50

Insulation Class:    H

Wave Form IEC = THF:  2.0%

Winding Pitch Code:   2/3 - 6

Total Harmonic Content LL/LN: 2.0%

Wires:  12

Supression is in line with European Standard

Radio Interference:       EN61000-6

Ingress Protection Rating:    IP23

Radiant Heat: kW (Btu/min)

 

-50 Hz:                                  27.8 (1581)

 

-60 Hz:                                           -

Excitation System:                                                 SHUNT

AVR Model:                                                             R448

P450P3 / P500E3

 

Technical Data

 

3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz,- RPM

 

 

Voltage         Prime Model                Standby Model          Voltage          Prime Model                Standby Model

                         P450P3                        P500E3                                            -                                  -

 

kVA                 kW

kVA                 kW

kVA                 kW

kVA                  kW

415/240V

450.0              360.0

500.0              400.0

 

 

400/230V

450.0              360.0

500.0              400.0

 

 

380/220V

450.0              360.0

500.0              400.0

 

 

230/115V

450.0              360.0

500.0              400.0

 

 

220/127V

430.0              344.0

473.0              378.4

 

 

220/110V

450.0              360.0

500.0              400.0

 

 

200/115V

450.0              360.0

500.0              400.0

 

 

 

Definitions

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).



Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

 

 

Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

 


 

Weights and Dimensions

 

Weights: kg (lb)                                                             Dimensions: mm (in)

Net (+ lube oil)

3793 (8362)

Length

3700 (145.7)

Wet (+ lube oil & coolant)

3831 (8446)

Width

1100 (43.3)

Fuel, lube oil & coolant

4615 (10174)

Height

2143 (84.4)

 

General Data

 

Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.

 

 

Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.

 

 

Warranty

All equipment carries full manufacturer's warranty.

 

Hot Products

Alternator Brand:Original Stamford Alternator Model:UCI274C Prime Power:80KW / 100KVA Frequency:50HZ ...
150kva Volvo Generator Diesel( JP-V120) Volvo Engine: TAD731GE Prime Power: 150KVA/120KW 150kva ...
Standby power:200 kW Prime power:182 kW Rated speed:1800 RPM Phase:3 Rated voltage:480 V 6 Cylinder ...
Model:TAD940GE Cylinder Arrangement:6 in line Air Intake System:Turbo Rated Power:240KW 240KW Single ...
Genset Model:JP-V250 Genset Output Power:250KW Rated Voltage:380/220V Frequency:50hz 4 stroke Volvo ...
​ 400KW IP21 Volvo Diesel Generator , Turbo Charged Generator Brand:VOLVO Genset Model:JP-V400 ...