Henan Swet Boiler Co., Ltd. |
Verified Suppliers
|
|
Product Description
1. High Quality and Reliable Oil Gas Burner.
High combustion efficiency and environmental protection.
2. Excellent coil design.
The spiral pipes are made of small diameter multi-head steel tubes,
good thermal expansibility, low stress, safe and reliable.
3. Large Diameter Furnace.
Large radiation heating area, increase thermal efficiency and
reduce the NOx emission.
4. High Thermal Efficiency.
1) Adopts three pass heating system, improve the heat utilization
efficiency.
2) Uses aluminium silicate board for heat preservation, high
thermal shielding efficiency.
3) By equipping with economizer, make full use of the heat of flue
gas.
5. High Quality boiler auxiliaries and multiple safety protection
devices.
(pressure controller, pressure transmitter, water level alarm,
safety valve, etc.)
6. Excellent Automatic System.
Adopts PLC full automatic intelligent control system, to ensure the
safe operation.
7. Convenient Maintenance
1) There are maintenance holes on the boiler, convenient for boiler
internal installation, inspection and clean.
2) The explosion proof equipment has the fire sight glass and
inspection gallery, it is convenient for furnace checking and
maintaining.
Protective device
1. Boiler equipped with autoalarm control system,function are as followed:
(1). High and low water level give sound and light alarm.
(2). Low water level interlock protection founction.
(3). Water level automatic control founction.
2. Boiler Fire off Protection :
If oil gas boiler fire off,if continue to supply fuel, the furnace may explode.This oil(gas) boiler burner equip with flam detection device,it can inspect the the furnace combustion condition.if gnition is failure or flamout halfway,it will close the oil(gas) solenoid vave in 5seconds(ignition),close the solenoid valve in 10 seconds(operation),and will Send out sound and light alarm signal. At this time,the forced draft fan continue working to blow off the flammable gas, after 20-30 seconds, the forced draft fan will stop working and all auxiliaries will power off automatically.
Technical Parameters
WNS series automatic gas (oil) steam energy saving boiler product selection form | Model | Unit | WNS6-1.25(1.6)-Q(Y) |
Rated capacity | t/h | 6 | |
Working pressure | Mpa | 1.25/1.6 | |
Steam temperature | ℃ | 194/204 | |
Feed temperature | ℃ | 105 | |
Testing efficiency | % | 96.58 | |
Diesel consumption | Kg/h | 379.32 | |
Gas consumption | Nm³/h | 433.51 | |
Outline dimension | mm(L*W*H) | 5470*2770*3195 |