HENAN TAIGUO BOILER PRODUCTS CO.,LTD. |
Verified Suppliers
|
|
LHG series biomass steam generator adopts automatic microcomputer control system, automatic control of equipment operation, no manual guard, automatic water intake system. Automatic pressure control system, automatic feeding system. With a low water level alarm and stop operation, overpressure alarm to stop the whole system, lower than the set pressure automatically start operation, reach the required maximum pressure automatically stop operation, using multiple safety design, safe and reliable. Factory configuration is complete, durable, safe and convenient. Fire tube arrangement structure, heating surface is large, temperature rise and steam production is fast. The modular machine is delivered with a water pump. Solenoid valve and check valve, only need to connect the power supply, steam pipe, water inlet pipe and sewage pipe can save the installation cost and a lot of installation materials. Will be your best choice.
LCD display automatic intelligent electronic control system:
The steam generator operating system is fully automatic control,
and all operating states can be clearly seen in the LCD screen. You
can observe the steam generator working status, steam generator
water level status, steam pressure high and low status, pump
operating status, fault alarm status, etc., so that you can grasp
the steam generator operating status at any time, the use of more
assured.
Multiple interlocking security protection features:
The product is equipped with safety valve, pressure controller,
overpressure protection, overtemperature, to prevent the steam
generator from being damaged due to excessive pressure; At the same
time, it has the limit low water level protection, and the steam
generator will automatically stop working when the water supply
stops, which prevents the dry burning of the steam generator from
causing damage or even burning of the electric heating element.
Leakage protector makes the safety of the operator and equipment
more guaranteed, even in the case of circuit short circuit and
leakage caused by improper operation of the steam generator, the
boiler will automatically cut off the circuit, and protect the
operator and control line in time.
Model |
Rated Capacity (t/h) |
Rated Pressure (Mpa) |
Rated Temperature (C) |
Maximum transport weight of boiler(t) |
Maximum transport size of boiler( mm) | Fuel Consumption | ||
diesel oil (Kg/h) |
Natural gas (m³/h) |
LPG (kg/h) | ||||||
LHS0.05 | 0.05 |
0.4 |
151 | 0.37 | 700× 650×1700 | 8.2 | 10.2 | 6.45 |
LHS0.1 | 0.1 | 0.59 | 800×750 ×2000 | 11.3 | 13.6 | 13 | ||
LHS0.2 | 0.2 |
0.4~0.7 |
151~170 | 0.68 | 900× 850×2000 | 15.6 | 18.7 | 19.4 |
LHS0.3 | 0.3 | 0.83 | 1000×950×2000 | 22.5 | 26.8 | 25.6 | ||
LHS0.5 |
0.5 |
1.07 |
1100×1050×2000 |
32.5 |
36.8 |
32 | ||
LHS0.7 |
0.7 |
0.4~0.7 |
151~170 |
1.45 |
1200×1150×2200 |
40.6 |
48.5 |
50 |
LHS1 |
1 |
1.78 |
1300×1250×2450 |
45.9 |
65.3 |
65 | ||
LHS1.5 | 1.5 |
1.9 |
1780×1600×3200 |
78.4 |
102.1 |
97 | ||
LHS2 |
2 |
5.2 |
2000×2000×4000 |
91.8 |
130.6 |
130 | ||
Note: 1,Fuel type:Light diesel oil/Heavy oil/Natural gas/Liquefied gas/City gas 2 ,Parameter is for reference only, we can design the boilers based on customers’ needs. |