The Zirconia Oxygen/Humidity Analyzer Is Designed With A High-Temperature Resistant Structure,Humidity And Oxygen Output
Here are some key details about zirconia oxygen analyzers:
- Measure the concentration of oxygen (O2) in a gas sample.
- Use a zirconium dioxide (ZrO2) sensor that conducts ions of
oxygen at high temperatures.
- The sensor tip is exposed to the sample gas on one side and a
reference gas (usually air) on the other.
- Oxygen ionizes on the sample side and migrates through the
zirconia sensor, causing a voltage difference proportional to the
O2 concentration.
- Operate at high temperatures 600-800°C to allow oxygen ion
conduction.
- Wide measuring range - can detect from ppm levels to 100% oxygen.
- Fast response times in the 10-20 seconds range.
- Not consumed or altered by the measurement, so a very long
lifetime.
- Require a conditioning period on startup to stabilize the sensor.
- Minimal drift so infrequent calibration required. Periodic air
calibration is adequate.
- Used widely for combustion control, inert gas blanketing, food
packaging, and other processes requiring oxygen measurement.
- Benefits are high accuracy, excellent repeatability, long term
stability.
- Limitations are high operating temperatures and susceptibility to
sensor cracking from thermal shock.
- Major manufacturers include ABB, Teledyne Analytical Instruments,
Fuji Electric, and Servomex.
In summary, zirconia oxygen analyzers offer excellent performance
for a wide span of O2 measurements in many industrial processes.
1. Using self-developedThe third generation of solid electrolyte oxygen measurement technology
2. Longer field service life and stronger corrosion resistance
3. Meet the simultaneous online monitoring requirements of two factors of humidity and oxygen
4. The product adds the air one-key calibration function, which makes the instrument calibration operation simple and efficient
5. Humidity, oxygen volume percentage output, meet environmental protection technical requirements
Measuring Principle | Limiting Current Method |
Detection Range | H2O 0~40 %VOL
O2 0~25 %VOL (optional) |
Measurement Accuracy | H2O ±2% FS
O2 ±1% FS (optional) |
Repeatability | ±1%FS |
Response Time | T90 < 20s |
Sampling Method | plug-in |
Installation Method | Standard DN65 flange, other specifications can be customized |
Rod Length | Standard length 800mm, other specifications can be customized |
Flue Gas Temperature | 0~250℃, 0~500℃ (can be customized) |
Display Method | LCD screen display, inside the instrument case |
Oxygen Calibration | Support oxygen zero point and span calibration (optional) |
Humidity Calibration | Support humidity zero point and span calibration |
Power Supply | 220VAC±10% 50HZ, 24W |
Ambient Temperature | -20℃~50℃ |
Environment Humidity | 5%~100% RH |
Degree Of Protection | IP65 |
Storage Temperature | -40℃~70℃ |
Storage Humidity | 5%~95% RH |
Power Failure Protection | Power-off blowback self-protection (optional) |