Itemthermal fuse, thermal cutoff, thermal link
Body Tyleplastic
Lead Dia0.6mm
Lead Length70mm
Voltage Rating250V ac
Current Rating3A
Mounting Type  radial leaded
Body Size6.2x6.3mm
Standards

IEC 60691 Ed4.0, GB/T 9816.2013

CertificationsUL VDE PSE CCC KTL

 

Dimension


Product Features

  • Rated Current: 250V 3A
  • Advantage: One shot operation
  • High sensitivity to ambient temperature
  • High accuracy and stability
  • Tiny structure
  • Excellent sealing structure

Specification

Model Noabcde
A-3A-F6.2±0.56.3±0.52.5±0.3Φ0.6±0.0270±3

 

Model NO.Tf(℃)

Fusing-off

Temperature(℃)

Th(℃)Tm(℃)Ir(A)Ur(V)
IECCorp
A0-3A-F84℃84 + 0 / -1082±2652032250
A1-3A-F102℃102 + 0 / -1098±2802032250
A2-3A-F115℃115 + 0 / -10112±3992032250
A3-3A-F125℃125 + 0 / -10120±31052032250
A4-3A-F130℃130 + 0 / -10126±21072032250
A5-3A-F135℃135 + 0 / -10131±31152032250
A7-3A-F138℃138 + 0 / -10135±21182032250
A12-3A-F145℃145 + 0 / -10140±21262032250
A8-3A-F150℃150 + 0 / -10145±31282032250
A16-3A-F160℃160 + 0 / -10155±21402032250

Temperature Rating (Tf):Rated opening temperature

Holding temperature (Th):Maximum temperature measured at the case end ofthe thermal cutoff at which the thermal cutoff  can be maintained for a period for 168 hours without opening.

Maximum temperature (Tm):The maximum temperature at which a thermal cutoff can be maintained for10 minutes as an open circuit and can then be maintained at twice rated voltage for a period of 2 minutes during which its mechanical and electrical properties will not be impaired

 

Structure

 

Applied to over-heat protection for all kinds of low-power motors, coils and etc.

APPLIANCES - space heaters, irons, stoves, electric blankets, hair dryers, clothes dryers, cookers,

toaster ovens,crock pots, mixers, toasters,microwave ovens, etc.

MOTORS - air conditioners,copiers, fans, washing machines, compressors,etc.

ELECTRONICS - TVs,stereos, tape recorders,video recorders, fluorescent lamps, transformers, computers, 

surge suppressors,telecommunication equipment, etc

 

Thermal Fuse Characteristics:
It consists of a sliding contact, a spring, and an electrically nonconductive thermal pellet.

Before the thermal fuse is activated, current flows from the left lead to the sliding contact

and through the metal housing to the right lead. When the external temperature reaches

a predetermined temperature, the organic matter meltsand the compression spring

becomes loose. That is, the spring expands and the sliding contact is separated from the
left lead. The circuit is opened and the current between the sliding contact and the left lead

is cut off.
 

Precautions When Using Thermal Cutoffs
The following information describes the correct methods of using thermal cutoffs to insure
proper and safe performance. To achieve the full use and capacity of a thermal cutoff, it is
necessary for the customer to exercise proper storage and execute appropriate circuit design,
proper installation, and adequate testing. Thermtrol Corporation does not assume responsibility
for problems which occur as a result of improper storage and installation, or inappropriate circuit
design, evaluations or tests.
• Do not use thermal cutoffs for purposes other than for what they are intended. Thermal cutoffs
operate only when they sense an ambient temperature greater than the factory pre-set temperature.
They have no ability to function by current overload and are not current limiting devices.
• Do not use thermal cutoffs in equipment, appliances or devices intended to be used in the
aerospace industry, aviation, nuclear power generation systems, life support systems, engine control
systems, or safety control systems for transportation. Thermal cutoffs are applicable for electrical
household devices, appliances and electronics. Other applications include: office automation equipment,
audiovisual equipment, communication systems, measuring instruments and specific transportation systems.
• Do not use thermal cutoffs in applications exceeding the listed ratings in the specification chart.
• Do not use thermal cutoffs in a liquid, in a corrosive atmosphere such as sulfurous gas, or in a high
humidity environment.
• Customers shall choose the thermal cutoff appropriate for the application and determine the proper
mounting position and/or method. To judge whether the selected thermal cutoff and chosen position
and method of mounting is suitable for the final application, we recommend that the customer fully test
and evaluate the unit in an environment that duplicates the final application as closely as possible.
This includes mounting and securing the thermal cutoff identically to the method that will be used in
production.
 

Standard Package

100pcs per bag, 10000pcs per carton

 

Shipping Term:

EXW, DDU, DDP, C&F, FOB

 

Shipping Methods:

International Express, By Air, By Sea

 

Test Equipment
  • Company warehouse
FAQ

Q: Are you trading company or manufacturer ?

A: We are a fuse product factory.

Q: How long is your delivery time?

A: Generally it is 3 days if the goods are in stock, 5-10 days if the goods not in stock, according to the quantity.

Q: Do you provide samples ? is it free or extra ?

A: Yes, we could offer the sample for free charge but do not pay the cost of freight.

Q: What is your terms of payment ?

A: 100% in advance, T/T.

Hot Products

Features of UL cuL VDE CQC PSE KC MTS Micro Fuse Radial Lead Slow Blow Square Fuse Miniature Fuse ...
R1245 456SDE 250V 40A 50A 60A High Current SMD Fuse Nano Surface Mount Chip Fuse Description Item ...
High Breaking Capacity Surface Mount Fuse Tape & Reel UMF Nano 3x10 SMD Fuse 250V Slo-Blo Descriptio...
SMD Fuse 250V 0.5A 0.75A 1A 1.25A 1.5A 2A 2.5A 3A 3.5A 4A 5A Nana Fuse 10mm Surface Mount Fuse ...
R1032 UL Certificate 3x10mm 250V 350V 16A SMD Fuse Gold Plated Description Item 3x10 SMD Fuse ...
1032 UL Approved 10 AMPS 3 x 10 250V 10A SMD Fuse for battery protection Description Item 3x10 SMD ...